CT-based synthetic contrast-enhanced dual-energy CT generation using conditional denoising diffusion probabilistic model

被引:0
|
作者
Gao, Yuan [1 ,2 ]
Qiu, Richard L. J. [1 ,2 ]
Xie, Huiqiao [3 ]
Chang, Chih-Wei [1 ,2 ]
Wang, Tonghe [3 ]
Ghavidel, Beth [1 ,2 ]
Roper, Justin [1 ,2 ]
Zhou, Jun [1 ,2 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 16期
基金
美国国家卫生研究院;
关键词
diffusion probabilistic model; single-energy CT; contrast-enhanced; dual-energy CT; deep learning; CONSENSUS;
D O I
10.1088/1361-6560/ad67a1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The study aimed to generate synthetic contrast-enhanced Dual-energy CT (CE-DECT) images from non-contrast single-energy CT (SECT) scans, addressing the limitations posed by the scarcity of DECT scanners and the health risks associated with iodinated contrast agents, particularly for high-risk patients. Approach. A conditional denoising diffusion probabilistic model (C-DDPM) was utilized to create synthetic images. Imaging data were collected from 130 head-and-neck (HN) cancer patients who had undergone both non-contrast SECT and CE-DECT scans. Main Results. The performance of the C-DDPM was evaluated using Mean Absolute Error (MAE), Structural Similarity Index (SSIM), and Peak Signal-to-Noise Ratio (PSNR). The results showed MAE values of 27.37 +/- 3.35 Hounsfield Units (HU) for high-energy CT (H-CT) and 24.57 +/- 3.35HU for low-energy CT (L-CT), SSIM values of 0.74 +/- 0.22 for H-CT and 0.78 +/- 0.22 for L-CT, and PSNR values of 18.51 +/- 4.55 decibels (dB) for H-CT and 18.91 +/- 4.55 dB for L-CT. Significance. The study demonstrates the efficacy of the deep learning model in producing high-quality synthetic CE-DECT images, which significantly benefits radiation therapy planning. This approach provides a valuable alternative imaging solution for facilities lacking DECT scanners and for patients who are unsuitable for iodine contrast imaging, thereby enhancing the reach and effectiveness of advanced imaging in cancer treatment planning.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Differentiating between benign and malignant breast lesions using dual-energy CT-based model: development and validation
    Xia, Han
    Chen, Yueyue
    Cao, Ayong
    Wang, Yu
    Huang, Xiaoyan
    Zhang, Shengjian
    Gu, Yajia
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [32] Deep Learning-Based Contrast Enhanced Dual-Energy CT Imaging From Non-Enhanced Single-Energy CT
    Xie, H.
    Lei, Y.
    Wang, T.
    Roper, J.
    Ghavidel, B.
    McDonald, M.
    Yu, D.
    Tang, X.
    Bradley, J.
    Liu, T.
    Yang, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E181 - E182
  • [33] Application of contrast-enhanced dual-energy spectral CT for differentiating borderline from malignant epithelial ovarian tumours
    Han, X.
    Li, B.
    Sun, M.
    Li, J.
    Li, Y.
    Liu, A.
    CLINICAL RADIOLOGY, 2021, 76 (08) : 585 - 592
  • [34] Clinical use of dual-energy CT for proton treatment planning to reduce CT-based range uncertainties
    Wohlfahrt, P.
    Moehler, C.
    Jakobi, A.
    Baumann, M.
    Enghardt, W.
    Krause, M.
    Greilich, S.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S70 - S71
  • [35] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jeong, Jiwoong
    Wentland, Andrew
    Mastrodicasa, Domenico
    Fananapazir, Ghaneh
    Wang, Adam
    Banerjee, Imon
    Patel, Bhavik N.
    ABDOMINAL RADIOLOGY, 2023, 48 (11) : 3537 - 3549
  • [36] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jiwoong Jeong
    Andrew Wentland
    Domenico Mastrodicasa
    Ghaneh Fananapazir
    Adam Wang
    Imon Banerjee
    Bhavik N. Patel
    Abdominal Radiology, 2023, 48 : 3537 - 3549
  • [37] Dual-Energy CT of Rectal Cancer Specimens: A CT-based Method for Mesorectal Lymph Node Characterization
    al-Najami, Issam
    Beets-Tan, Regina G. H.
    Madsen, Gunvor
    Baatrup, Gunnar
    DISEASES OF THE COLON & RECTUM, 2016, 59 (07) : 640 - 647
  • [38] Detection and characterization of urinary stones using material-specific images derived from contrast-enhanced dual-energy CT urography
    Cheng, Yannan
    Zhang, Lu
    Cao, Le
    Zhang, Xianghui
    Qu, Tingting
    Li, Jianying
    Chen, Jiao
    He, Hui
    Yang, Jian
    Guo, Jianxin
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1152):
  • [39] Intravenous contrast-enhanced CT can be used for CT-based attenuation correction in clinical 111In-octreotide SPECT/CT
    Klausen T.L.
    Mortensen J.
    de Nijs R.
    Andersen F.L.
    Højgaard L.
    Beyer T.
    Holm S.
    EJNMMI Physics, 2 (1) : 1 - 13
  • [40] Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
    Liu, Chi-Kuang
    Liu, Chih-Chieh
    Yang, Cheng-Hsun
    Huang, Hsuan-Ming
    JOURNAL OF DIGITAL IMAGING, 2021, 34 (01) : 149 - 161