Behaviour of a Cold-Formed Steel Shear Wall with Centre-Corrugated Steel Sheathing under Cyclic Loading

被引:0
|
作者
Xie, Zhiqiang [1 ]
Shi, Leilei [2 ]
Peng, Lingyun [2 ]
Zhang, Shi [1 ]
Zhou, Daxing [3 ]
Zhang, Xiangdong [3 ]
Yu, Cheng [4 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Civil & Transportat Engn, Beijing 100044, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] China Railway Construction Grp Co Ltd, Beijing 100043, Peoples R China
[4] Univ North Texas, Dept Engn Technol, Denton, TX USA
基金
中国国家自然科学基金;
关键词
CCSS-CFS shear wall; Seismic performance; Failure mechanism; Calculation method; Nominal shear strength; BUCKLING BEHAVIOR;
D O I
10.1016/j.engstruct.2024.118650
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A cold-formed steel shear wall with centre-corrugated steel sheathing (CCSS-CFS shear wall) was innovatively developed to meet the requirement of earthquake resistance for multi-rise CFS structures in regions at high seismic risk. This wall exhibits superior seismic performance in comparison with the conventional CFS shear wall. Five full-size specimens were tested under cyclic loading to evaluate their failure mode, shear strength, lateral stiffness, ductility, energy dissipation, as well as degradation of bearing capacity and stiffness. Additionally, the effects of CFS frame structure forms, screw spacing, and corrugated steel sheet thicknesses on the behaviour and failure mechanism of shear walls were analysed. The seismic performance objectives corresponding to intact, slight, moderate, and severe damage were also determined. The results revealed that the main failure modes of shear walls were plastic buckling of corrugated steel sheathing and local buckling of the end composite stud. Optimising configurations such as setting up stiffening plates on the end composite stud, installing transverse braces, and increasing screw spacing between composite studs and sheathing significantly improved their behaviour. The strength of corrugated steel sheathing after plastic buckling should be taken into consideration for the lateral design of the CCSS-CFS shear wall. A calculation method was also proposed in order to determine the elastic global buckling shear strength of the CCSS-CFS shear wall - which exhibited high accuracy. Finally, nominal shear strength, a resistance factor, and a safety factor were recommended.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Seismic performance of cold-formed steel framed shear walls with steel sheathing and gypsum board
    Feng, Ruo-qiang
    Zhu, Baochen
    Xu, PengHui
    Qiu, Yun
    THIN-WALLED STRUCTURES, 2019, 143
  • [22] Detailing recommendations for 1.83 m wide cold-formed steel shear walls with steel sheathing
    Yu, Cheng
    Chen, Yujie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (01) : 93 - 101
  • [23] Optimization of Cold-Formed Steel Framed Shear Wall Sheathed with Corrugated Steel Sheets: Experiments and Dynamic Analysis
    Yu, Cheng
    Yu, Guowang
    Wang, Jie
    Structures Congress 2015, 2015, : 1008 - 1020
  • [24] Sheathing Bracing Requirements for Cold-formed Steel Wall Panels: Experimental Investigation
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    STRUCTURES, 2019, 19 : 258 - 276
  • [25] Lateral behaviour of steel plate shear wall with cold-formed steel strips reinforcing door opening
    Wang, Kang
    Wang, Yu-Hang
    Gao, Yuan
    Zhou, Xu-Hong
    Tan, Ji-Ke
    Qi, Hao
    THIN-WALLED STRUCTURES, 2023, 190
  • [26] Experimental study on cold-formed steel shear walls with different corrugated steel sheathings
    Liu, Xiyu
    Zhang, Wenying
    Yu, Cheng
    Li, Yi
    Jiang, Ziqin
    Yu, Shaole
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [27] Shape optimisation of cold-formed steel framed wall studs with sheathing restraints
    Dias, Yomal
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2021, 158
  • [28] Behavior of cold-formed steel wall panels under monotonic horizontal loading
    Baran, Eray
    Alica, Cagatay
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 : 1 - 8
  • [29] Behaviour of cold-formed steel hollow beam with perforation under flexural loading
    Sangeetha, P.
    Revathi, S. M.
    Sudhakar, V
    Swarnavarshini, D.
    Sweatha, S.
    MATERIALS TODAY-PROCEEDINGS, 2021, 38 : 3103 - 3109
  • [30] Behaviour of wrapped cold-formed steel columns under different loading conditions
    Baabu, B. Hari
    Sreenath, S.
    INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND INFRASTRUCTURAL ISSUES IN EMERGING ECONOMIES (ICCIEE 2017), 2017, 80