Fast voltage recovery method based on DC bus voltage change after LVRT

被引:0
|
作者
Yang, Ruojia [1 ]
Yan, Xiangwu [1 ]
Jia, Jiaoxin [1 ]
Shen, Zhongyu [2 ]
机构
[1] North China Elect Power Univ, Baoding 071000, Hebei, Peoples R China
[2] State Grid Tianjin Elect Power Co, Construct Branch, Tianjin 300143, Peoples R China
关键词
Inverter; Low voltage ride-through; DC bus voltage control; Inverter control; STRATEGY;
D O I
10.1016/j.epsr.2024.110481
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At present, the researches on abnormal voltage ride-through of photovoltaic power mainly focus on the control method during voltage fault, and few researchers pay attention to whether the transition stage after voltage fault meets the requirements. Aiming at the phenomenon that after the photovoltaic power has successfully ridded through the low or high voltage faults the recovery speed of DC bus voltage is slower than that when the fault occurs, the operation state change process of the photovoltaic power encountering abnormal voltage faults is analyzed from the electrical level in this paper firstly. And based on this, the necessity and working principle of abnormal voltage ride-through control strategy are introduced. Then, according to the P-U U curve of the photovoltaic array and the change principle of the inverter DC bus voltage, the reasons for this phenomenon are analyzed from two angles. Finally, a method that can effectively improve the recovery speed of the DC bus voltage is proposed. The method is verified by simulation under various working conditions, which provides a new method for improving the abnormal voltage ride-through performance of photovoltaic power.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A Fast Assessment Method for Voltage Stability in Multi-Bus Power System
    Nagendra, P.
    Sunita, H.
    Paul, Subrata
    Datta, Tanaya
    Chennaiah, P. B.
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 2890 - 2895
  • [42] DC Bus Voltage Sliding-mode Control for a DC Microgrid Based on Linearized Feedback
    Liang, Chunhui
    Zhang, Yunbo
    Ji, Xiu
    Meng, Xiangping
    An, Yinping
    Yao, Qi
    2019 CHINESE AUTOMATION CONGRESS (CAC2019), 2019, : 5380 - 5384
  • [43] Effect of voltage-loop controllers on bus voltage fluctuation and recovery time in voltage source converters
    Gitau, MN
    Enslin, JHR
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 98) - PROCEEDINGS, VOLS 1 AND 2, 1998, : 208 - 213
  • [44] A New DC Decoupling-based DC Bus Voltage Optimisation Strategy for Energy Routers
    Chen, Shiwei
    Jiang, Lujun
    Tu, Huajun
    2024 9TH INTERNATIONAL CONFERENCE ON ELECTRONIC TECHNOLOGY AND INFORMATION SCIENCE, ICETIS 2024, 2024, : 160 - 165
  • [45] A Fast and Simple Fault Diagnosis Method for Interleaved DC-DC Converters Based on Output Voltage Analysis
    Li, Po
    Li, Xiang
    Zeng, Tao
    ELECTRONICS, 2021, 10 (12)
  • [46] Efficiency Optimization of a Variable Bus Voltage DC Microgrid
    Garcia Elvira, David
    Valderrama Blavi, Hugo
    Cid Pastor, Angel
    Martinez Salamero, Luis
    ENERGIES, 2018, 11 (11)
  • [47] Control of DC bus voltage with a Modular Multilevel Converter
    Samimi, S.
    Gruson, F.
    Guillaud, X.
    Delarue, P.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [48] Nonliear-Disturbance-Observer Based DC-Bus Voltage Control for DC Microgrid
    Hong, Zhu
    Yu, Dongsheng
    Chen, Hao
    Cheng, He
    Zan, Xiaoshu
    2016 14TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION (ICARCV), 2016,
  • [49] Drive DC bus voltage control during power interruptions using kinetic energy recovery
    Terbörde, G
    Driesen, J
    Belmans, R
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 243 - 247
  • [50] A Nonlinear Disturbance Observer Based DC Bus Voltage Control for a Hybrid AC/DC Microgrid
    Li, Xialin
    Wang, Chengshan
    Guo, Li
    Li, Yunwei
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 1655 - 1662