Prediction of New-Onset Atrial Fibrillation in Transcatheter Aortic Valve Implantation

被引:1
|
作者
Karakulak, Ugur Nadir [1 ]
Sahiner, Levent [1 ]
Kaya, Ergun Baris [1 ]
Sener, Yusuf Ziya [1 ]
Ates, Ahmet Hakan [1 ]
Aytemir, Kudret [1 ]
Ozer, Necla [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Cardiol, TR-06100 Ankara, Turkiye
关键词
Atrial fibrillation; Tissue Doppler imaging; Total atrial conduction time; Transcatheter aortic valve implantation; EUROPEAN ASSOCIATION; STENOSIS; IMPACT; REPLACEMENT; GUIDELINES; FREQUENCY; OUTCOMES; DISEASE; SURGERY;
D O I
10.6515/ACS.202407_40(4).20240201A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study investigates the association between prolonged total atrial conduction time and the development of new-onset atrial fibrillation (AF) following transcatheter aortic valve implantation (TAVI). Methods: We enrolled 307 patients who underwent TAVI. Total atrial conduction time was calculated as the time between the onset of the P wave on the electrocardiography and the peak of the a ' wave velocity (PA-TDI duration) on tissue Doppler imaging echocardiography. Results: A total of 263 patients were analyzed after excluding 44 with pre-existing AF. Of these 263 patients, 47 (17.8%) experienced new-onset AF after the TAVI procedure. The new-onset AF group had an older median age (80.6 vs. 77.5 years) and a higher incidence of paravalvular aortic regurgitation than those without AF (none 29.8%, mild 46.8%, moderate 23.4%). The new-onset AF group had increased end-systolic diameter (35.0 vs. 31.7 mm, p = 0.03), left atrial diameter (44.7 vs. 41.9 mm, p = 0.049), and PA-TDI duration (137.0 vs. 125.4 ms, p = 0.009). Older age, the presence of paravalvular aortic regurgitation, and prolonged PA-TDI duration were independently associated with new-onset AF in multivariate analysis. The optimal cut-off value for PA-TDI duration was 123.5 ms. Conclusions: AF in patients treated with TAVI may pose significant risks for morbidity and mortality. PA-TDI duration, a readily available echocardiographic parameter, can detect patients with a high risk of new-onset AF.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 50 条
  • [41] Incidence, pathophysiology, predictive factors and prognostic implications of new onset atrial fibrillation following transcatheter aortic valve implantation
    Koniari, Ioanna
    Tsigkas, Grigorios
    Kounis, Nikolaos
    Velissaris, Dimitrios
    Chourdakis, Emmanouil
    Davlouros, Periklis
    Hahalis, George
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (01) : 50 - 54
  • [42] Does New Onset Atrial Fibrillation Have a True Impact on the Incidence of Stroke After Transcatheter Aortic Valve Implantation?
    Salinas, Pablo
    Moreno, Raul
    Sanchez-Recalde, Angel
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Calvo, Luis
    Plaza, Ignacio
    Lopez-Sendon, Jose
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (03) : 236 - 237
  • [43] Silent New- Onset Atrial Fibrillation After Transcatheter Aortic Valve Replacement
    Nuche, Jorge
    Soliman, Fady
    Viquez, Jorge Chavarria
    Okoh, Alexis
    Mora, Hugo Alvarado
    Nault, Isabelle
    Philippon, Francois
    Natarajan, Madhu
    Russo, Mark
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B40 - B41
  • [44] Impact of atrial fibrillation between transcatheter aortic valve implantation and surgical aortic valve replacement
    Jeong, Hyung Ki
    Yoon, Namsik
    Kim, Min Chul
    Lee, Ki Hong
    Yoon, Hyun Ju
    Kim, Kye Hun
    Park, Hyung Wook
    Kim, Ju Han
    Ahn, Youngkeun
    Jeong, Myung Ho
    Cho, Jeong Gwan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1494 - 1495
  • [45] New-Onset Atrial Fibrillation After Aortic Valve Replacement: Evaluation of a National Cohort
    Kalra, Rajat
    Patel, Nirav
    Doshi, Rajkumar
    Arora, Garima
    Arora, Pankaj
    CIRCULATION, 2018, 138
  • [46] Postprocedural Atrial Fibrillation After Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement
    Motloch, Lukas J.
    Reda, Sara
    Rottlaender, Dennis
    Khatib, Rosa
    Mueller-Ehmsen, Jochen
    Seck, Catherine
    Strauch, Justus
    Madershahian, Navid
    Erdmann, Erland
    Wahlers, Thorsten
    Hoppe, Uta C.
    ANNALS OF THORACIC SURGERY, 2012, 93 (01): : 124 - 132
  • [47] Preoperative predictors of new-onset prolonged atrial fibrillation after surgical aortic valve replacement
    Axtell, Andrea L.
    Moonsamy, Philicia
    Melnitchouk, Serguei
    Tolis, George
    Jassar, Arminder S.
    D'Alessandro, David A.
    Villavicencio, Mauricio A.
    Cameron, Duke E.
    Sundt, Thoralf M., III
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (04): : 1407 - 1414
  • [48] Rhythm outcomes after aortic valve surgery: Treatment and evolution of new-onset atrial fibrillation
    Xiang, Bitao
    Ma, Wenrui
    Yan, Shixin
    Chen, Jinmiao
    Li, Jun
    Wang, Chunsheng
    CLINICAL CARDIOLOGY, 2021, 44 (10) : 1432 - 1439
  • [49] New-Onset Arrhythmias After Transcatheter Aortic Valve Replacement May Not Always Be New-Onset Arrhythmias
    Toggweiler, Stefan
    Kobza, Richard
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1774 - 1776
  • [50] New-onset arrhythmias following transcatheter aortic valve implantation: a systematic review and meta-analysis
    Siontis, George C. M.
    Praz, Fabien
    Lanz, Jonas
    Vollenbroich, Rene
    Roten, Laurent
    Stortecky, Stefan
    Raber, Lorenz
    Windecker, Stephan
    Pilgrim, Thomas
    HEART, 2018, 104 (14) : 1208 - +