Serial kinematic analysis using inertial measurement units in growing dogs at risk of hip dysplasia

被引:0
|
作者
Blattler, P. [1 ]
Altermatt, M. [2 ]
Rohrich, M. [3 ]
Grutter, N. [2 ]
机构
[1] Orthovet, Fasanenstr 13, CH-4402 Frenkendorf, Switzerland
[2] Univ Appl Sci Northwestern Switzerland, Inst Med Engn & Med Informat, Sch Life Sci, Hofackerstr 30, CH-4132 Muttenz, Switzerland
[3] HSEF Sro, Druzstevni 84, Brezi 69181, Czech Republic
来源
关键词
Inertial measurement unit; Canine gait; Movement analysis; Gait characteristics;
D O I
10.1016/j.vas.2024.100385
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
In this study, 54 dogs were examined at regular intervals from 12 weeks to 15 months of age using a gait analysis system based on inertial measurement sensors. At the end of the study, the dogs were examined for hip dysplasia (HD) and elbow dysplasia (ED) under sedation and officially classified at the Dysplasia Commission in Zurich. Gait parameters which are characteristic for the gait pattern of dogs, were calculated according to recent publications. These parameters were analysed for variance throughout the entire study period and assigned to healthy dogs and those suffering from HD. The findings of the study show that dogs suffering from HD exhibit a more unsteady gait pattern, e.g. higher variance, as they grow.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] External Load Analysis in Beach Handball Using a Local Positioning System and Inertial Measurement Units
    Mueller, Carsten
    Willberg, Christina
    Reichert, Lukas
    Zentgraf, Karen
    SENSORS, 2022, 22 (08)
  • [42] A Clinical Study on Total Hip Replacement using Cemented Prosthetics for Management of Hip Dysplasia in Dogs
    Venkatesh, N.
    Reddy, K. Jagan Mohan
    Sekhar, E. L. Chandra
    Rajendranath, N.
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2024, 58 (08) : 1283 - 1293
  • [43] Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty
    Zugner, Roland
    Tranberg, Roy
    Timperley, John
    Hodgins, Diana
    Mohaddes, Maziar
    Karrholm, Johan
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [44] CLINICAL HIP-DYSPLASIA IN GROWING-DOGS - THE LONG-TERM RESULTS OF CONSERVATIVE MANAGEMENT
    BARR, ARS
    DENNY, HR
    GIBBS, C
    JOURNAL OF SMALL ANIMAL PRACTICE, 1987, 28 (04) : 243 - 252
  • [45] SERUM CONCENTRATIONS OF PROCOLLAGEN TYPE-III AMINOTERMINAL PEPTIDE IN GROWING DOGS WITH HIP-DYSPLASIA
    MADSEN, JS
    SVALASTOGA, E
    JENSEN, LT
    ACTA VETERINARIA SCANDINAVICA, 1995, 36 (01) : 157 - 160
  • [46] Repeatability of Inertial Measurement Units for Measuring Pelvic Mobility in Patients Undergoing Total Hip Arthroplasty
    Vayalapra, Sushanth
    Wang, Xueyang
    Qureshi, Arham
    Vepa, Abhinav
    Rahman, Usama
    Palit, Arnab
    Williams, Mark A. A.
    King, Richard
    Elliott, Mark T. T.
    SENSORS, 2023, 23 (01)
  • [47] Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty
    Roland Zügner
    Roy Tranberg
    John Timperley
    Diana Hodgins
    Maziar Mohaddes
    Johan Kärrholm
    BMC Musculoskeletal Disorders, 20
  • [48] Inertial Measurement Units and Application for Remote Health Care in Hip and Knee Osteoarthritis: Narrative Review
    Rose, Michael J.
    Costello, Kerry E.
    Eigenbrot, Samantha
    Torabian, Kaveh
    Kumar, Deepak
    JMIR REHABILITATION AND ASSISTIVE TECHNOLOGIES, 2022, 9 (02)
  • [49] Quantitative Shape Measurement of an Inflatable Rubber Dam Using an Array of Inertial Measurement Units
    Hu, Yonghui
    Yan, Yong
    Efstratiou, Christos
    Vela-Orte, David
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [50] Human Activity Recognition Using Inertial Measurement Units and Smart Shoes
    Chinimilli, Prudhvi Tej
    Redkar, Sangram
    Zhang, Wenlong
    2017 AMERICAN CONTROL CONFERENCE (ACC), 2017, : 1462 - 1467