Analysis of the assembly pressure of a high-power molten carbonate fuel cell stack during initial roasting

被引:0
|
作者
Zhang, Ruiyun [1 ,2 ]
Han, Minfang [2 ]
Xu, Shisen [3 ]
Lu, Chengzhuang [1 ]
Zhang, Hanfei [4 ]
Wang, Jinyi [1 ]
机构
[1] Huaneng Clean Energy Res Inst Co Ltd, State Key Lab Efficient & Flexible Coal Elect & Ca, Beijing 102209, Peoples R China
[2] Tsinghua Univ, Dept Energy & Power Engn, Beijing 100084, Peoples R China
[3] China Huaneng Grp Co Ltd, Beijing 100031, Peoples R China
[4] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
关键词
Molten carbonate fuel cell; Stack; Roasting; Assembly pressure; CO2; CAPTURE; SYSTEM; PLANT; SEPARATION;
D O I
10.1016/j.fuel.2024.132895
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study investigated the effect of the assembly pressure during the initial roasting of a 15 kW molten carbonate fuel cell (MCFC) stack on its performance, with the aim of enhancing the success rate of large-area, highpower stacks. The corresponding assembly scheme was designed to possess an intermediate intake structure for ensuring a uniform intake distribution along the vertical axis of the MCFC stack. Monitoring the correlation between the settling distance of the MCFC stack and roasting temperature revealed the crucial stage of diaphragm roasting and identified the appropriate compensation period for pressure loss, thereby enhancing the success rate of the initial roasting process. At an assembly pressure of 4.35 MPa, the MCFC stack exhibited a constant voltage of 84 V, achieving a maximum output power of 16.51 kW and discharge current density exceeding 95 mA/cm2, thereby confirming the effectiveness of the assembly scheme and initial roasting process.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Dairy biogas as fuel for a molten carbonate fuel cell-initial study
    Milewski, J. (milewski@itc.pw.edu.pl), 1600, Warsaw University of Technology (93):
  • [32] Dairy biogas as fuel for a Molten Carbonate Fuel Cell-initial study
    Milewski, Jaroslaw
    Michalska, Karina
    Kacprzak, Anna
    JOURNAL OF POWER TECHNOLOGIES, 2013, 93 (03): : 161 - 168
  • [33] Performance of miniature single molten carbonate fuel cell (MCFC) and MCFC stack
    Li, Fei
    Chen, Gang
    Liu, Yu
    Wang, Chun-Ming
    Hu, Ke-Ao
    Dianyuan Jishu/Chinese Journal of Power Sources, 2002, 26 (01):
  • [34] Fabrication and operational experiences of a 6 kW molten carbonate fuel cell stack
    Seong-Ahn Hong
    Tae-Hoon Lim
    Suk-Woo Nam
    In-Hwan Oh
    Hee Chun Lim
    Korean Journal of Chemical Engineering, 2000, 17 : 193 - 197
  • [35] Hybrid Dynamic Modeling and Control of Molten Carbonate Fuel Cell Stack Shutdown
    李勇
    曹广益
    朱新坚
    Journal of Donghua University, 2007, (01) : 35 - 38
  • [36] Numerical studies of a separator for stack temperature control in a molten carbonate fuel cell
    Kim, Do Hyung
    Kim, Beom Joo
    Lim, Hee Chun
    Lee, Choong Gon
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (14) : 8499 - 8507
  • [37] Hybrid dynamic modeling and control of molten carbonate fuel cell stack shutdown
    Li, Yong
    Cao, Guang-Yi
    Zhu, Xin-Jian
    Journal of Donghua University (English Edition), 2007, 24 (01) : 35 - 38
  • [38] Economic analysis of a combined heat and power molten carbonate fuel cell system
    Hengeveld, Derek W.
    Revankar, Shripad T.
    JOURNAL OF POWER SOURCES, 2007, 165 (01) : 300 - 306
  • [39] MOLTEN-CARBONATE FUEL-CELL STACK PERFORMANCE WITH GAS RECYCLING
    WATANABE, T
    IZAKI, Y
    MUGIKURA, Y
    ABE, T
    SAITO, H
    MATSUYAMA, T
    SHIMIZU, T
    SATO, S
    OGOSHI, M
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (06) : 35 - 47
  • [40] Improvements of a molten carbonate fuel cell power plant via exergy analysis
    Braun, RJ
    Gaggioli, RA
    Dunbar, WR
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1999, 121 (04): : 277 - 285