Switching Frequency Control Strategy of Inverter for Multifrequency Multiload WPT System Based on Hysteresis Current Control

被引:1
|
作者
Xia, Chenyang [1 ]
Chen, Yuhang [1 ]
Sun, Anran [1 ]
Cao, Yuheng [1 ]
Wang, Xirui [1 ]
Wang, Qi [1 ]
机构
[1] China Univ Min & Technol, Sch Elect Engn, Xuzhou 221116, Peoples R China
基金
中国国家自然科学基金;
关键词
Control systems; Switching frequency; Inverters; Frequency control; Resonant frequency; Delays; Switches; Blocking delay control; fixed switching frequency; hysteresis current control; low switching frequency; multifrequency and multiload (MFML); wireless power transfer (WPT); WIRELESS POWER TRANSFER; DESIGN;
D O I
10.1109/TPEL.2024.3416671
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the complexity of current variation of the multifrequency and multiload (MFML) wireless power transfer (WPT) system based on hysteresis current (HC) control, resulting in a wide range of switching frequency variation, high frequency, and high switching losses of the inverter. This article proposes a blocking delay switching frequency control strategy. Based on the design of blocking delay module, the time division blocking delay and full-time fixed frequency blocking delay control modes are investigated, which can reduce the inverter switching frequency fluctuation range and fix the inverter switching frequency respectively. First, the structure and working principle of the MFML WPT system based on HC control containing passive compensation network are analyzed. Second, the system switching frequency characteristics are analyzed. Third, for different system switching frequency limitation requirements, time division blocking delay control mode and full-time fixed-frequency blocking delay control mode are proposed. Finally, an experimental platform is built to verify the proposed control strategy, the experimental results show that the system switching frequency of different parameters is reduced to within 200 kHz and 180 kHz in the time division blocking delay control, and the system switching frequency is fixed to 150 kHz and 250 kHz in the full-time fixed-frequency blocking delay control.
引用
收藏
页码:13946 / 13961
页数:16
相关论文
共 50 条
  • [21] Constant-frequency hysteresis current control of PV grid-connected inverter
    College of Information Engineering, Xiangtan University, Xiangtan 411105, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2008, 4 (58-62):
  • [22] Torque and current control of induction motor drives for inverter switching frequency reduction
    Huang, CY
    Wei, CP
    Yu, JT
    Hu, YJ
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (05) : 1364 - 1371
  • [23] FPGA based sequential switching control strategy for a three phase inverter
    Polic, Ales
    Jezernik, Karel
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 3013 - 3018
  • [24] Analysis and prediction of inverter switching frequency in direct torque control of induction machine based on hysteresis bands and machine parameters
    Kang, JK
    Sul, SK
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (03) : 545 - 553
  • [25] A Novel DC Loop Current Control Strategy for Paralleled UPS Inverter System Based on Decoupled Control Scheme
    He Guofeng
    Xu, Dehong
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 70 - 75
  • [26] Development of Digital Hysteresis Current Control with PLL Loop Gain Compensation Strategy for PWM Inverters with Constant Switching Frequency
    Belhaouchet, N.
    Rahmani, L.
    Begag, S.
    Hamla, H.
    JOURNAL OF ELECTRICAL SYSTEMS, 2008, 4 (01) : 77 - 90
  • [27] Maximum Efficiency Tracking of WPT System Based on Frequency Tracking Control
    Zheng, Zhongjiu
    Wang, Yunhe
    Zhu, Jingwei
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (10) : 1701 - 1710
  • [28] Hybrid hysteresis current control and low-frequency current harmonics mitigation based on proportional resonant in dc/ac inverter
    Zhang, Haiyu
    Li, Xiao
    Xiao, Shunlong
    Balog, Robert S.
    IET POWER ELECTRONICS, 2018, 11 (13) : 2093 - 2101
  • [29] Research on Current Control Strategy for Grid-Connected Inverter Based on Passivity Based Control
    Chen, Zong-xiang
    Ge, Lu-sheng
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 79 - 83
  • [30] Indirect Current Control Algorithm Implementation for an Active Filtering System Using Constant Switching Frequency Hysteresis Controllers
    Linca, Mihaita
    Suru, Constantin Vlad
    Preda, Cristina Alexandra
    2018 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2018,