Intial Developmental Testing of High Voltage Insulation for Rotating Machines

被引:0
|
作者
Thatcher, Kyle [1 ]
George, Brian [2 ]
机构
[1] Von Roll USA, Applicat Tech Support, Schenectady, NY 12306 USA
[2] Von Roll USA, Tech Sales Support, Schenectady, NY USA
关键词
High Voltage; Dissipation Factor; Voltage Endurance; Mica System;
D O I
10.1109/EIC58847.2024.10579378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Insulation systems are a necessary component in the motor design world. While development can typically run smoothly from start to finish, there are often setbacks and struggles that can delay the creation of an insulation system. Various components which may seem ideal for pairing may not work in a practical or testing environment. Typical industry tests used to evaluate insulation systems include voltage endurance, dissipation factor and processing tap test. A novel, environmentally friendly, low VOC resin system designed for medium voltage (up to 7.2 kV) was investigated and compared with a classical system. Further testing was performed for high voltage applications (13.8 kV) as well. This paper explores the different aspects of medium and high voltage insulation systems development. For example, while we achieved much greater voltage endurance results than that of existing, proven high voltage systems; mixed dissipation factor tests and visible puffing of the main wall insulation suggested limitations of the system for high voltage applications.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 50 条
  • [41] Voltage Endurance Testing Stator insulation systems for inverter-fed machines
    Stranges, Meredith K. W.
    Stone, Greg C.
    Bogh, Dennis L.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2009, 15 (06) : 12 - 18
  • [42] A HIGH-VOLTAGE TEST GENERATOR FOR INSULATION TESTING
    ELLISON, DH
    EXON, JLT
    BRYAN, AB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (11): : 1046 - 1051
  • [43] DIAGNOSTIC TESTING OF HIGH-VOLTAGE MACHIEN INSULATION
    MILLER, R
    BLACK, IA
    HOGG, WK
    WOOD, JW
    MASON, JH
    SIMONS, JS
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1980, 127 (06): : 386 - 388
  • [44] MECHANICAL TESTING OF HIGH VOLTAGE STATOR INSULATION SYSTEMS
    MAUGHAN, CV
    GIBBS, EE
    GIAQUINT.EV
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (08): : 1946 - &
  • [45] Development and Validation of Reliability Testing Methods for Insulation Systems in High-Voltage Rotating Electrical Machinery on Ships
    Kim, Hyeun-Chul
    Kim, Jong-Su
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2025, 13 (02)
  • [46] Investigation of Mica Based Insulation for High Voltage Machines Subjected to Repetitive Pulsed Voltage
    Sahlen, Fredrik
    Ming, Li
    Johansson, Kenneth
    Martensson, Eva
    Koponen, Osmo
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [47] Suppression of Partial Discharges in High-Voltage Rotating Machines
    Chapman, M.
    Bruetsch, R.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 338 - +
  • [48] Insulating Systems for High Voltage Rotating Machines and Reliability Considerations
    Bruetsch, Rudolf
    Chapman, Michael
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [49] Tool to design the primary electrical insulation system of low voltage rotating machines fed by inverters
    Collin Philippe
    Malec David
    Lefevre Yvan
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 8 - 13
  • [50] Online Insulation Monitoring System for Rotating Machines
    Ohki, Yoshimichi
    IEEE ELECTRICAL INSULATION MAGAZINE, 2019, 35 (05) : 47 - 49