OptiBreathe: An Earable-based PPG System for Continuous Respiration Rate, Breathing Phase, and Tidal Volume Monitoring

被引:3
|
作者
Romero, Julia [1 ,2 ]
Ferlini, Andrea [1 ]
Spathis, Dimitris [1 ]
Dang, Ting [1 ]
Farrahi, Katayoun [1 ,3 ]
Kawsar, Fahim [1 ]
Montanari, Alessandro [1 ]
机构
[1] Nokia Bell Labs, Cambridge, England
[2] Univ Colorado, Boulder, CO 80309 USA
[3] Univ Southampton, Southampton, Hants, England
来源
PROCEEDINGS OF THE 2024 THE 25TH INTERNATIONAL WORKSHOP ON MOBILE COMPUTING SYSTEMS AND APPLICATIONS, HOTMOBILE 2024 | 2024年
关键词
PPG; Earables; Breathing Phases; Tidal Volume; BIOACOUSTIC METHOD; AWAKE;
D O I
10.1145/3638550.3641136
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In the continuous quest to push the boundaries of mobile healthcare and fitness tracking, monitoring respiratory biomarkers emerges as a pivotal frontier. In this paper, we present OptiBreathe, a light-weight on-device earable system designed to decode the respiratory modulations within photoplethysmography (PPG) signals. OptiBreathe computes three clinical respiratory biomarkers towards enabling continuous respiratory health monitoring with wearable devices. In our effort to bridge respiratory research and earable computing, we collected a first-of-its-kind dataset that empowers researchers to explore in-ear PPG alongside gold-standard spirometry-based ground truth in order to measure respiration rate, breathing phases, and tidal volume. OptiBreathe employs multiple algorithms to measure each respiratory parameter, achieving a best mean absolute error (MAE) of 1.96 breaths per minute on respiratory rate. When estimating breathing phases and tidal volume, OptiBreathe attains an MAE of 0.48 seconds on inspiratory time, 0.14 on inhalation-exhalation ratio (inhalation duration divided by exhalation duration), and a best mean absolute percentage error (MAPE) of 17% on tidal volume (averaged across subjects). This work shows that the best performing algorithm depends on individuals' unique physiology, and that future research should investigate the relationship between physiological factors and algorithm performances. As we look forward, we highlight the challenges and nuances in harnessing PPG sensors for respiratory monitoring, inviting researchers to build upon our work.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 37 条
  • [21] System for Continuous Monitoring of the Corrosion Rate in Concrete Reinforcement based on Bimetallic Batch Sensors
    D. S. Shevtsov
    I. D. Zartsyn
    E. S. Komarova
    Protection of Metals and Physical Chemistry of Surfaces, 2021, 57 : 1388 - 1394
  • [22] Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System
    Mack, David C.
    Patrie, James T.
    Suratt, Paul M.
    Felder, Robin A.
    Alwan, Majd
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (01): : 111 - 120
  • [23] Effects Of A High-Flow Nasal Cannula System (HFNC) On Tidal Volume, Breathing Rate And I/E-Ratio In Healthy Volunteers And Patients With COPD
    Braeunlich, J.
    Koehler, M.
    Seyfarth, H-J.
    Hammerschmidt, S.
    Wirtz, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [24] Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source
    Dent, Paul
    Tun, Sai Han
    Fillioe, Seth
    Deng, Bin
    Satalin, Josh
    Nieman, Gary
    Wilcox, Kailyn
    Searles, Quinn
    Narsipur, Sri
    Peterson, Charles M.
    Goodisman, Jerry
    Mostrom, James
    Steinmann, Richard
    Chaiken, J.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XVI, 2018, 10484
  • [25] Internet of Things (IoT) Based Continuous Growth275 Rate Monitoring System of Plant Stem
    Nayak, Shikha
    Das, Subir
    Chakraborty, Badal
    Chakraborty, Tanmoy
    Roy, Kishor
    PROCEEDINGS OF 3RD IEEE CONFERENCE ON VLSI DEVICE, CIRCUIT AND SYSTEM (IEEE VLSI DCS 2022), 2022, : 275 - 279
  • [26] Continuous Respiratory Rate Estimation Approach Based on Phase Features Using Array Radar in Home Sleeping Monitoring
    Zheng, Yuxizi
    Yang, Zhaocheng
    Luo, Bing
    Chu, Ping
    Zhou, Jianhua
    IEEE SENSORS JOURNAL, 2024, 24 (12) : 19352 - 19363
  • [27] A system for monitoring and measuring the volume flow rate of a liquid based on the M1821BM85A microprocessor
    Sukhomlinov, GL
    Chernyshev, VA
    Sevost'yanov, SS
    MEASUREMENT TECHNIQUES, 2004, 47 (04) : 359 - 362
  • [28] A System for Monitoring and Measuring the Volume Flow Rate of a Liquid Based on the M1821BM85A Microprocessor
    G. L. Sukhomlinov
    V. A. Chernyshev
    S. S. Sevost'yanov
    Measurement Techniques, 2004, 47 : 359 - 362
  • [29] Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system
    McGrath, Susan P.
    Pyke, Joshua
    Taenzer, Andreas H.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (03) : 561 - 569
  • [30] Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system
    Susan P. McGrath
    Joshua Pyke
    Andreas H. Taenzer
    Journal of Clinical Monitoring and Computing, 2017, 31 : 561 - 569