Point-of-Care Testing of Whole Blood for Liver Injury Auxiliary Diagnosis with Biothiols Activable Chemiluminescent Probe

被引:5
|
作者
Zhu, Jingxuan [2 ]
Xu, Shuai [1 ,3 ]
Zhou, Lei [2 ]
Zeng, Qin [2 ]
Wang, Yuhan [4 ]
Yan, Mei [1 ]
Liu, Hongwen [2 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Hunan Normal Univ, Affiliated Hosp 1, Coll Chem & Chem Engn, Changsha 410081, Peoples R China
[3] Qingdao Univ Sci & Technol, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Shandong Key Lab Biochem Anal, Coll Chem & Mol Engn,MOE, Qingdao 266042, Peoples R China
[4] Shandong Normal Univ, High Sch Attached, Jinan 250014, Peoples R China
基金
中国国家自然科学基金;
关键词
FLUORESCENT-PROBE; DISCRIMINATION; CHEMISTRY; CYSTEINE; COMPLEX;
D O I
10.1021/acs.analchem.4c02831
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liver injury significantly affects a patient's health and quality of life. However, timely and convenient diagnosis of this disease via whole blood detection remains challenging due to the lack of user-friendly and fast readout blood test methods. Herein, we developed such a method for the swift auxiliary diagnosis of liver injury via whole blood detection using a customed point-of-care testing (POCT) system consisting of a biothiols-activatable chemiluminescent probe and a hand-held POCT device. Biothiols served as the target to build the activable chemiluminescence probe due to their abnormal level in liver injury. Compared with fluorescent and electrical POCTs, this method is more convenient and has strong universality. By incorporating cyclodextrin via host-guest chemistry, we intensified chemiluminescence while mitigating chemical hemolysis caused by the dissolution of organic molecules, making this system suitable for whole blood analysis. Preliminary assessments in aqueous solutions, living cells, and mouse models confirmed its sensitivity, reliability, and feasibility. Simply mixing blood with the probe for 30 min yielded a clear signal readout within 15 s on the POCT device. Utilizing this portable detector, the reduced biothiol level was tested in 18 liver injury patient blood samples, and the results were similar to those measured by a commercial kit and in vivo imaging system. Thus, this work provides a universal platform for the fast and convenient detection of other biomarkers in whole blood samples and opens up possibilities for the rapid clinical diagnosis of diseases, enabling patients to conduct home self-examinations with ease.
引用
收藏
页码:12584 / 12592
页数:9
相关论文
共 50 条
  • [31] Clinical evaluation of the first medical whole blood, point-of-care testing device for detection of myocardial infarction
    Apple, FS
    Anderson, FP
    Collinson, P
    Jesse, RL
    Kontos, MC
    Levitt, MA
    Miller, EA
    Murakami, MM
    CLINICAL CHEMISTRY, 2000, 46 (10) : 1604 - 1609
  • [32] GLUCOTROL-WB: A HIGHLY COMMUTABLE WHOLE BLOOD QUALITY CONTROL FOR GLUCOSE POINT-OF-CARE TESTING
    Huizing, C. J.
    Jungerius, B. J.
    Phaup, D.
    Maas, B. H. A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S680 - S680
  • [33] Point-of-Care i-STAT Testing for the Diagnosis of Meliodosis
    Sfeir, Maroun M.
    CLINICAL INFECTIOUS DISEASES, 2020, 70 (11) : 2455 - 2456
  • [34] Point-of-Care Testing in the Diagnosis of Deep Vein Thrombosis: A Review
    Zhang, Zejun
    Wu, Junding
    Cheng, Wanjun
    Zhang, Xia
    Xu, Lisheng
    Yao, Yudong
    IEEE SYSTEMS MAN AND CYBERNETICS MAGAZINE, 2023, 9 (02): : 49 - 56
  • [35] Advanced point-of-care biomarker testing for the diagnosis of cardiovascular diseases
    Ming, Wenjun
    Zhu, Yidan
    Jiang, Wenjun
    Zhang, Jing
    Liu, Jinxia
    Wu, Li
    Qin, Yuling
    SENSING AND BIO-SENSING RESEARCH, 2025, 47
  • [36] Evaluation of immunochromatographic point-of-care testing in diagnosis of pulmonary tuberculosis
    El Hadidy H.F.
    Raafat D.
    El-Emshaty W.M.
    Mahmoud L.A.
    Comparative Clinical Pathology, 2017, 26 (4) : 741 - 747
  • [37] An anti-interference fluorescent probe for point-of-care diagnosis of albuminuria
    Zhao, Xiongfei
    Zheng, Weidong
    Qin, Tianyi
    Du, Xinfeng
    Lei, Yanmei
    Lv, Taoyuze
    Zhou, Mei
    Xu, Zhongyong
    Wang, Lei
    Liu, Bin
    Peng, Xiaojun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 351
  • [38] Value of point-of-care blood testing in emergent trauma management
    Asimos, AW
    Gibbs, MA
    Marx, JA
    Jacobs, DG
    Erwin, RJ
    Norton, HJ
    Thomason, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (06): : 1101 - 1108
  • [39] White blood cell counting at point-of-care testing: A review
    Luo, Jianke
    Chen, Chunmei
    Li, Qing
    ELECTROPHORESIS, 2020, 41 (16-17) : 1450 - 1468
  • [40] MicroRNA-122 can be measured in capillary blood which facilitates point-of-care testing for drug-induced liver injury
    Vliegenthart, A. D. Bastiaan
    Berends, Cecile
    Potter, Carmelita M. J.
    Kersaudy-Kerhoas, Maiwenn
    Dear, James W.
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2017, 83 (09) : 2027 - 2033