Electrochemical Properties of Nickel-Titanium Rotary Endodontic Instruments

被引:2
|
作者
Subramanian, Vidyalakshmi [1 ]
Roberts, Howard W. [1 ,2 ]
Han, Shengtong [3 ]
Sidow, Stephanie J. [4 ]
Berzins, David W. [1 ]
机构
[1] Marquette Univ, Sch Dent, Dept Gen Dent Sci Dent Biomat, Milwaukee, WI USA
[2] Univ Kentucky, Coll Dent, Lexington, KY USA
[3] Marquette Univ, Sch Dent, Dept Gen Dent Sci Biostat, Milwaukee, WI USA
[4] Marquette Univ, Sch Dent, Dept Surg & Diagnost Sci Endodont, Milwaukee, WI USA
关键词
Corrosion current; endodontic rotary files; nickel-titanium; saline; sodium hypochlorite; LOW-CYCLE FATIGUE; SODIUM-HYPOCHLORITE; MECHANICAL-PROPERTIES; CORROSION-RESISTANCE; CLEANING PROCEDURES; FRACTURE PROPERTIES; FILES; IMMERSION; BEHAVIOR; CHLORIDE;
D O I
10.1016/j.joen.2024.05.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Nickel-titanium rotary endodontic files have been commercially available for decades, but more recent innovations have introduced heat-treated and surface-treated files. This study investigated the corrosion properties of various nickel-titanium files in normal saline and sodium hypochlorite (NaOCl). Methods: Ten different file brands of size 40 with a 0.04 taper were subjected to electrochemical testing in 0.9% NaCl (saline) and 5.25% NaOCl at room temperature. The Open Circuit Potential (OCP) was observed for 1 hour followed by a cyclic polarization test from- 300 to 700 mV and back to- 300 mV (vs OCP). Nonparametric ANOVA and a pairwise comparison (P P < .05) were used for statistical analysis of the OCP at 1 hour and the corrosion current (Icorr) obtained via the cyclic polarization test. Results: Significant differences (P P < .05) were found between files with respect to OCP and Icorr in both solutions. Nine files exhibited significantly greater (P P < .05) Icorrs in NaOCl than in saline. Conversely, pitting corrosion was observed in the saline solution but not NaOCl. Weak and/or moderate correlations existed between OCP and Icorr measures in the 2 solutions. Conclusion: Significant differences in electrochemical properties were observed among the 10 brands of files. Overall, there was not a clear trend between conventional, heat-treated, or surface-treated files among OCP or Icorr in either solution.
引用
收藏
页码:1143 / 1150
页数:8
相关论文
共 50 条
  • [41] Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    Haïkel, Y
    Serfaty, R
    Bateman, G
    Senger, B
    Allemann, C
    JOURNAL OF ENDODONTICS, 1999, 25 (06) : 434 - 440
  • [42] Influence of Different Manufacturing Methods on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Rodrigues, Renata C. V.
    Lopes, Helio P.
    Elias, Carlos N.
    Amaral, Georgiana
    Vieira, Victor T. L.
    De Martin, Alexandre S.
    JOURNAL OF ENDODONTICS, 2011, 37 (11) : 1553 - 1557
  • [43] SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    Alapati, SB
    Brantley, WA
    Svec, TA
    Powers, JM
    Nusstein, JM
    Daehn, GS
    JOURNAL OF ENDODONTICS, 2005, 31 (01) : 40 - 43
  • [44] Factors influencina defects of rotary nickel-titanium endodontic instruments after clinical use
    Parashos, P
    Gordon, I
    Messer, HH
    JOURNAL OF ENDODONTICS, 2004, 30 (10) : 722 - 725
  • [45] Effects of sodium hypochlorite on corrosion of the rotary nickel-titanium endodontic instruments - SEM analysis
    Jovanovic-Medojevic, Milica
    Neskovic, Jelena
    Popovic-Bajic, Marijana
    Stratimirovic, Dorde
    Zivkovic, Slavoljub
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2022, 150 (5-6) : 254 - 260
  • [46] Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments
    Bahia, MGA
    Melo, MCC
    Buono, VTL
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 101 (05): : 675 - 680
  • [47] Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue
    Stojanac, Igor
    Drobac, Milan
    Petrovic, Ljubomir
    Atanackovic, Teodor
    DENTAL MATERIALS JOURNAL, 2012, 31 (04) : 650 - 655
  • [48] Electrochemical-induced dissolution of nickel-titanium endodontic instruments with different designs
    Ormiga, F.
    Aboud, L. R. L.
    Gomes, J. A. C. P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (04) : 342 - 350
  • [49] Influence of Electrochemical Polishing on the Mechanical Properties of K3 Nickel-Titanium Rotary Instruments
    Galvao Barbosa, Fabiola Ormiga
    da Cunha Ponciano Gomes, Jose Antonio
    Pimenta de Araujo, Marcos Cesar
    JOURNAL OF ENDODONTICS, 2008, 34 (12) : 1533 - 1536
  • [50] Influence of structure on nickel-titanium endodontic instruments failure
    Kuhn, G
    Tavernier, B
    Jordan, L
    JOURNAL OF ENDODONTICS, 2001, 27 (08) : 516 - 520