Cerebral Protection With Deep Hypothermic Circulatory Arrest During Total Arch Replacement Using the Arch-First Technique for Acute Aortic Dissection

被引:0
|
作者
Okada, Kimiaki [1 ]
Kotani, Sohsyu [1 ]
Ozawa, Keisuke [1 ]
Kishinami, Goro [1 ]
Yamamoto, Akiyoshi [1 ]
Cho, Yasunori [1 ]
机构
[1] Tokai Univ, Sch Med, Cardiovasc Surg, Tokai, Kanagawa, Japan
关键词
dissection with patent false lumen; stroke due to air embolism; acute type a aortic dissection; deep hypothermic circulatory arrest(dhca); total arch replacement; MORTALITY; PERFUSION; ANEURYSM; SURGERY; REPAIR; MALPERFUSION; STROKE;
D O I
10.7759/cureus.66640
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Stroke remains a serious complication after total arch replacement (TAR). To prevent this, deep hypothermia is commonly employed during TAR. We evaluated the effectiveness of cerebral protection using deep hypothermic circulatory arrest (DHCA) during TAR with the arch-first technique, focusing particularly on patients with acute aortic dissection (AAD). Methods: This retrospective study included 109 consecutive patients with AAD who underwent emergency TAR using the arch-first technique under DHCA, and 147 patients with non-ruptured aneurysm who underwent scheduled TAR using the same technique between October 2009 and July 2022. We reviewed these patients for major adverse events, including stroke and 30-day mortality after surgery. We also analyzed the impact of clinical variables and anatomical features on the occurrence of newly developed stroke after TAR in patients with AAD. Results: A newly developed stroke after TAR occurred in 11 (10.1%) patients with AAD. These were attributed to embolism in eight patients, malperfusion in two patients (including one who had been comatose), and low output syndrome in one patient. A stroke occurred in 3 (2.0%) patients with aneurysm, all due to embolism (P = 0.005). The DHCA time was 37 +/- 7 minutes for patients with AAD and 36 +/- 6 minutes for patients with aneurysm (P = 0.122). The 30-day mortality rate was 10 (9.2%) for patients with AAD and 2 (1.4%) for patients with aneurysm (P = 0.003). In our multivariable analysis, arch vessel dissection with a patent false lumen (double-barreled dissection) was the only significant predictor of newly developed stroke after TAR for AAD (odds ratio, 33.02; P < 0.001). Conclusions: Patients with aneurysm undergoing TAR using the arch-first technique under DHCA experienced significantly better outcomes, in terms of newly developed stroke and 30-day mortality, than those with AAD. Cerebral protection with DHCA during TAR using the arch-first technique continues to be a viable option. Newly developed stroke in patients undergoing TAR for AAD appears to be associated with air emboli deriving from the residual dissection with a patent false lumen in the repaired arch vessels.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A modified total arch replacement combined with a stented elephant trunk implantation for acute type A dissection under deep hypothermic circulatory arrest and selective antegrade cerebral perfusion
    Su-Min Yang
    Ping Xu
    Cheng-Xiang Li
    Qiang Huang
    Hong-Bo Gao
    Zhen-Fu Li
    Qing Chang
    Journal of Cardiothoracic Surgery, 9
  • [42] Acute Kidney Injury After Total Aortic Arch Repair with Moderate Hypothermic Circulatory Arrest
    Hiraoka, Arudo
    Chikazawa, Genta
    Totsugawa, Toshinori
    Sakaguchi, Taichi
    Tamura, Kentaro
    Yoshitaka, Hidenori
    JOURNAL OF CARDIAC SURGERY, 2014, 29 (02) : 218 - 224
  • [43] Safety of Hypothermic Circulatory Arrest During Unilateral Antegrade Cerebral Perfusion for Aortic Arch Surgery
    Wang, Xiaomeng
    Yang, Feng
    Wang, Liangshan
    Hou, Dengbang
    Zhu, Junming
    Liu, Yongmin
    Sun, Lizhong
    Hou, Xiaotong
    CANADIAN JOURNAL OF CARDIOLOGY, 2019, 35 (11) : 1483 - 1490
  • [44] Results of aortic arch repair with hypothermic circulatory arrest and retrograde cerebral perfusion
    Hilgenberg, AD
    Logan, DL
    JOURNAL OF CARDIAC SURGERY, 2001, 16 (03) : 246 - 251
  • [45] Mild Hypothermic Circulatory Arrest with Lower Body Perfusion for Total Arch Replacement Via Upper Hemisternotomy in Acute Type A Dissection
    Jiang, Hui
    Liu, Yu
    Yang, Zhonglu
    Ge, Yuguang
    Du, Yejun
    HEART SURGERY FORUM, 2021, 24 (02): : E345 - E350
  • [46] How to make a total aortic arch replacement without global circulatory arrest. The branch first technique
    Danduch, Gabriel
    Battellini, Roberto
    Domenech, Alberto
    Kotowicz, Vadim
    CIRUGIA CARDIOVASCULAR, 2018, 25 (04): : 204 - 207
  • [47] Hypothermic Circulatory Arrest Using Antegrade Cerebral Perfusion Is Safe for Elective Aortic Arch Surgery
    Matt, Peter
    Albrecht, Franziska
    Rueter, Florian
    Grapow, Martin
    Pargger, Hans
    Fassl, Jens
    Reuthebuch, Oliver
    Eckstein, Friedrich
    THORACIC AND CARDIOVASCULAR SURGEON, 2013, 61 (07): : 553 - 558
  • [48] Less Invasive total arch replacement for acute type A aortic dissection -Total Arch Replacement with Branched Open Stentgrafting Technique
    Takeuchi, Mugho
    Kuratani, Toru
    Sawa, Yoshiki
    CIRCULATION, 2008, 118 (18) : S613 - S613
  • [49] Moderate and deep hypothermic circulatory arrest has a comparable effect on acute kidney injury after total arch replacement with frozen elephant trunk procedure in type A aortic dissection
    Fang, Zhongrong
    Wang, Guyan
    Liu, Qing
    Zhou, Hui
    Zhou, Shan
    Lei, Guiyu
    Zhang, Congya
    Yang, Lijing
    Shi, Sheng
    Li, Jun
    Qian, Xiangyang
    Sun, Xiaogang
    Wei, Bo
    Yu, Cuntao
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (01) : 130 - 136
  • [50] Sedatives during circulatory arrest are not necessary for aortic arch repair in acute type A aortic dissection
    Makkinejad Alexander O.
    Clemence Jeffrey
    Norton Elizabeth L.
    Farhat Linda
    Wu Xiao-Ting
    Ferman Daniel H.
    Yang Bo
    中华医学杂志英文版, 2021, 134 (02) : 219 - 221