New insight for simultaneous detection of methocarbamol and paracetamol in human serum samples based on poly(L-methionine)/graphene-graphene oxide nanocomposite

被引:2
|
作者
Ahmed, Yousef M. [1 ]
El-Zanaty, Mohamed R. [1 ]
Galal, Ahmed [1 ]
Atta, Nada F. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
关键词
Methocarbamol; Paracetamol; Poly (L-methionine); Graphene oxide; Reduced graphene oxide; Serum samples; CARBON-PASTE ELECTRODE; SKELETAL-MUSCLE RELAXANTS; HUMAN PLASMA; GRAPHENE OXIDE; SPECTROFLUOROMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; ACETAMINOPHEN; TABLETS; HPLC;
D O I
10.1016/j.microc.2024.111370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new insight is presented for simultaneous detection of methocarbamol (MET), and paracetamol (PAR), in human serum samples. The design of an electrochemical sensor is achieved by modifying the surface of a glassy carbon electrode (GCE) with two successive thin films from conductive poly(L-methionine) (PMT) and a mixture of reduced graphene oxide and graphene oxide (RGO-GO). The composite is characterized by scanning electron microscopy (SEM), atomic force microscope (AFM), and Fourier transform infrared spectroscopy (FT-IR). The sensor creates a powerful sensing platform for MET and PAR detection with kinetically enhanced oxidation process. An increase in the anodic current responses for MET and PAR is obtained with 10.1 and 5.9 times higher compared to bare GC electrode, respectively. Mixing GO with RGO increases the surface area, and the reactive sites due to presence of oxygen-functional groups at its surface. The sensor has good stability, repeatability, reproducibility, and anti-interference capability. The detection limits are 5.2 nM and 1.2 nM for the determination of MET and PAR simultaneously in serum sample in the concentration range (0.04 -> 100 mu M). Large peak potential separation between the MET and PAR about 822 mV is attained. The assay of drugs in serum samples and pharmaceutical formulations is successfully achieved with good recovery values.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Electrochemical sensor based on reduced graphene oxide/carbon black/chitosan composite for the simultaneous determination of dopamine and paracetamol concentrations in urine samples
    Baccarin, Marina
    Santos, Fabricio A.
    Vicentini, Fernando C.
    Zucolotto, Valtencir
    Janegitz, Bruno C.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 436 - 443
  • [22] Versatile electrode platform for determination of hydrogen peroxide in serum samples based on hemoglobin embedded in iron oxide/reduced graphene oxide nanocomposite
    Kalaiselvi, Subburayan
    Kumar, Deivasigamani Ranjith
    Hasan, Mahmudul
    Santhanalakshmi, Jayadevan
    Manoj, Devaraj
    Khalid, Mohammad
    Shim, Jae-Jin
    ELECTROCHIMICA ACTA, 2023, 471
  • [23] Anti-Biofouling Electrochemical Sensor Based on the Binary Nanocomposite of Silica Nanochannel Array and Graphene for Doxorubicin Detection in Human Serum and Urine Samples
    Lv, Ning
    Qiu, Xun
    Han, Qianqian
    Xi, Fengna
    Wang, Yina
    Chen, Jun
    MOLECULES, 2022, 27 (24):
  • [24] Simultaneous detection of telomerase and miRNA with graphene oxide-based fluorescent aptasensor in living cells and tissue samples
    Ou, Xiaowen
    Zhan, Shenshan
    Sun, Chunli
    Cheng, Yong
    Wang, Xudong
    Liu, Bifeng
    Zhai, Tianyou
    Lou, Xiaoding
    Xia, Fan
    BIOSENSORS & BIOELECTRONICS, 2019, 124 : 199 - 204
  • [25] Co3O4/reduced Graphene Oxide Composite as An Enhanced Material for Electrochemical Detection of Paracetamol in Human Serum
    陈华林
    黄启同
    胡世荣
    唐淑丽
    杨浩
    李占明
    ChineseJournalofStructuralChemistry, 2020, 39 (06) : 1035 - 1043
  • [26] Co3O4/reduced Graphene Oxide Composite as An Enhanced Material for Electrochemical Detection of Paracetamol in Human Serum
    Chen Hua-Lin
    Huang Qi-Tong
    Hu Shi-Rong
    Tang Shu-Li
    Yang Hao
    Li Zhan-Ming
    CHINESE JOURNAL OF STRUCTURAL CHEMISTRY, 2020, 39 (06) : 1035 - 1043
  • [27] Simultaneous Electrochemical Analysis of Uric Acid and Xanthine in Human Saliva and Serum Samples Using a 3D Reduced Graphene Oxide Nanocomposite-Modified Electrode
    Han, Seong-Hyun
    Moon, Ki Won
    Lee, Yun Jong
    Lee, Gi-Ja
    CHEMOSENSORS, 2023, 11 (03)
  • [28] Reduced Graphene Oxide Non-covalent Functionalized with Zinc Tetra Phenyl Porphyrin Nanocomposite for Electrochemical Detection of Dopamine in Human Serum and Rat Brain Samples
    Sakthinathan, Subramanian
    Kubendhiran, Subbiramaniyan
    Chen, Shen Ming
    Manibalan, Kesavan
    Govindasamy, Mani
    Tamizhdurai, P.
    Huang, Sheng Tung
    ELECTROANALYSIS, 2016, 28 (09) : 2126 - 2135
  • [29] SENSITIVE SIMULTANEOUS DETERMINATION OF PARACETAMOL AND DICLOFENAC BASED ON Au NANOPARTICLES - FUNCTIONALIZED GRAPHENE/POLY (L-ARGININE) GLASSY CARBON ELECTRODE
    Afshar, Esmail
    Jalali, Fahimeh
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2016, 61 (01): : 2846 - 2851
  • [30] A highly sensitive electrochemical sensor for simultaneous detection of uric acid, xanthine and hypoxanthine based on poly(L-methionine) modified glassy carbon electrode
    Ojani, Reza
    Alinezhad, Ali
    Abedi, Zahra
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 621 - 630