Comparison of two novel geothermal-powered cooling systems based on 4E evaluations

被引:2
|
作者
Akhoundi, Mahla [1 ]
Deymi-Dashtebayaz, Mahdi [1 ]
Asadi, Mostafa [1 ]
Rad, Ehsan Amiri [1 ]
机构
[1] Hakim Sabzevari Univ, Ctr Computat Energy, Dept Mech Engn, Sabzevar, Iran
关键词
Cooling production cycles; Conventional exergy analysis; Exergo-economic analysis; Advanced exergy analysis; Exergy destruction; ADVANCED EXERGY ANALYSIS; KALINA CYCLE; EXERGOECONOMIC ANALYSIS; REFRIGERATION CYCLE; ENERGY; OPTIMIZATION; DRIVEN; HEAT;
D O I
10.1007/s10098-024-03011-w
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this research, two innovative cooling systems are introduced that utilize low-temperature geothermal energy as an alternative to fossil fuels. Systems A and B utilize different subsystems: A uses the organic Rankine cycle (ORC), Kalina cycle (KC), and vapor compression refrigeration cycle (VCRC), while B integrates KC, VCRC, and the absorption refrigeration cycle (ARC). The proposed systems were analyzed using multiple techniques, including energy analysis, conventional exergy analysis (CEA), exergo-economic analysis (EEA), and advanced exergy analysis (AEA). Based on the results obtained, system A shows a modified exergy efficiency of 25.6% and a total cost of 117.9 $/s, while system B demonstrates an efficiency of 36.7% and a total cost of 35.3 $/s. Therefore, the proposed systems perform better thermodynamically and economically when using ARC rather than ORC. CEA states that specific components such as evaporators and generators, undergo significant exergy destruction. On the other hand, the AEA indicates that for both systems A and B, the most significant avoidable endogenous exergy destruction is related to VCRC's condenser (37% for system A, 30.2% for system B), followed by the compressor (21% for system A, 17.2% for system B) and KC's condenser (10.1% for system A, 13.2% for system B). Therefore, CEA and AEA prioritize components improvement differently. Based on the exergy destruction cost rate, the EEA recommends prioritizing the improvement of the VCRC's condenser (29.2% for system A, 23.8% for system B), VCRC's valve (17.39% for system A, 14.19% for system B), and compressor (14.2% for system A, 9.9% for system B). Accordingly, the EEA and AEA have different priorities for improving components, which should be considered based on the goal, whether it's cost-saving or system efficiency. It has also been discovered that a considerable amount of avoidable exergy destruction in system A is exogenous in the ORC (84.4%) and KC (83.4%), while endogenous in the VCRC (61.83%). Consequently, optimizing the VCRC can significantly improve system A's performance. Similarly, the VCRC should be prioritized to enhance system B's performance. The findings of this study can be used to inform decision-making and optimize the design and operation of the proposed systemsQuery.
引用
收藏
页数:31
相关论文
共 50 条
  • [31] Energy, exergy, exergoeconomic, and environmental (4E) analyses of a novel combined cooling and power system with phosphoric acid fuel cell and Kalina cycle
    Einanlou, Mehrdad
    Mehregan, Mahmood
    Hashemian, Seyed Majid
    APPLIED THERMAL ENGINEERING, 2023, 221
  • [32] 4E analyses and multi-objective optimization of a solar-based combined cooling, heating, and power system for residential applications
    Karim, Taher
    Tofiq, Tofiq Ahmed
    Shariati, Mortaza
    Rad, Hima Nikafshan
    Ghasemi, Amir
    ENERGY REPORTS, 2021, 7 : 1780 - 1797
  • [33] 4E analyses and multi-objective optimization of a solar-based combined cooling, heating, and power system for residential applications
    Karim, Sarkhel H. Taher
    Tofiq, Tofiq Ahmed
    Shariati, Mortaza
    Nikafshan Rad, Hima
    Ghasemi, Amir
    Nikafshan Rad, Hima (Hima.Nikafshan@gmail.com), 1780, Elsevier Ltd (07): : 1780 - 1797
  • [34] Robust and efficient zero liquid discharge design strategy using four novel desalination systems: A comprehensive 4E assessment
    Ghofrani, Iraj
    Moosavi, Ali
    JOURNAL OF CLEANER PRODUCTION, 2021, 310
  • [35] System Analysis and Comparison Between a 2 MW Conventional Liquid Cooling System and a Novel Two-Phase Cooling System for Fuel Cell-Powered Aircraft
    van Gerner, Henk Jan
    Luten, Tim
    Resende, William
    Muehlthaler, Georg
    Buntz, Marcus-Benedict
    ENERGIES, 2025, 18 (04)
  • [36] Investigating 4E analyses and multi-objective optimization of a novel data center compression/ejection transcritical CO2 cooling system
    Qin, Xiang
    Shen, Aoqi
    Duan, Hongxin
    Liu, Hongzhi
    Wang, Dingbiao
    Liu, Heyu
    Wang, Guanghui
    APPLIED THERMAL ENGINEERING, 2025, 264
  • [37] 4E analysis and optimization of a novel combined cooling, heating and power system integrating compressed air and chemical energy storage with internal combustion engine
    Yao, Erren
    Zhong, Like
    Li, Ruixiong
    Zhao, Chenxi
    Wang, Huanran
    Xi, Guang
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [38] Modeling and 4E analysis of a new combined cooling, heating, and power energy system based on biogas combustion and hot oil for heat supply
    Tian, Hongjun
    Chen, Xiaowei
    Ahmad, Sayed Fayaz
    Agrawal, Manoj Kumar
    Seikh, Asiful H.
    Shah, Nehad Ali
    Su, Qiaolin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 184 : 1484 - 1501
  • [39] Design and energy, exergy, thermoeconomic, and exergo-environmental (4E) analyses of a novel hybrid geothermal/biogas-powered green multi-generation system using a post-combustion CO2 capture unit
    Liu, Jian
    Hsu, Chou-Yi
    Ahmad, Sayed Fayaz
    Alotaibi, Majed A.
    Allahham, Mahmoud Izzat
    Qin, Muxing
    APPLIED ENERGY, 2025, 377
  • [40] Simulation and 4E analysis of a novel trigeneration process using a gas turbine cycle combined with a geothermal-driven multi-waste heat recovery method
    Chen, Feng
    Zhang, Wei
    Liu, Yi
    Cai, Jie
    Zhang, JinLing
    Wang, XunMing
    Su, Qiaolin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 176 : 1026 - 1047