Exploring The Viability of Variable Speed mSyr Motor for Air-Conditioning Applications

被引:0
|
作者
Mohammed, Mohammed Jabal [1 ]
Tuncay, R. Nejat [1 ]
机构
[1] Istanbul Okan Univ, Dept Elect Engn, Fac Engn, Istanbul, Turkiye
关键词
Reluctance motor; Permanent magnet; Saliency ratio; Insulation ratio; Average torque; Torque ripple; Power factor; SYNCHRONOUS RELUCTANCE MACHINES; DESIGN OPTIMIZATION; PM; PERFORMANCE; FERRITE; ROBUST; SYNRM;
D O I
10.1109/GPECOM61896.2024.10582668
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Previously, air conditioners commonly relied on single-phase induction motors to drive compressors, controlled by a simple on-off mechanism. These motors operated directly from AC mains without an inverter, maintaining a constant rotational speed. However, in recent years, there has been a noticeable shift towards enhancing energy production and consumption due to increasing environmental concerns and a growing carbon dioxide footprint. Part of these improvements focus on energy consumption resampled by induction motors, which often experience relatively high losses. Therefore, enhancing their efficiency or replacing them with more energy-friendly alternatives could significantly reduce overall energy consumption. Potential candidates for this purpose include Synchronous Reluctance (Syr) motors, particularly with the additional improvement of magnet assistance, alongside Permanent Magnet Synchronous Motors (PMSM). This study deals with air-conditioning kind of loads employing a Permanent Magnet-Assisted Synchronous Reluctance (mSyr) motor. The suitability of mSyr motors for constant torque variable speed loads is investigated, along with the evaluation of design parameters and optimization methodologies. Increases in efficiency and power factor (PF), as well as a decrease in torque ripple, are achieved.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
  • [21] Staged variable air volume air-conditioning system and its application in stores
    Zhao, JN
    Guo, J
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1247 - 1253
  • [22] Experimental research of operation performance of the capillary radiant air-conditioning terminal integrated with DC variable speed new air unit
    Chen, Jianbo
    Cheng, Fei
    Li, Fen
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 547 - 552
  • [23] Online optimal allocation scheme on operation number of parallel variable-speed pumps in air-conditioning system
    Zhao, Tian-Yi
    Zhang, Ji-Li
    Sun, De-Xing
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2011, 44 (03): : 221 - 226
  • [24] Speed Ripple Suppression of Reduced DC-link Capacitance IPMSM Drives for Air-Conditioning Applications
    Bai, Yin
    Zhao, Nannan
    Wang, Gaolin
    Zhang, Guoqiang
    Xu, Dianguo
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 3039 - 3044
  • [25] Energy Studies on Central and Variable Refrigerant Flow Air-Conditioning Systems
    Abdullah, H.
    Nitamakwuavan, S.
    Jalaludin, A. F.
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 486 - 490
  • [26] Modeling and simulation of variable air volume air-conditioning system and its control strategy
    Zhao, Zhe Shen
    Wu, Ye
    Lue, Jibin
    PROCEEDINGS OF THE 16TH IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2007, : 376 - 381
  • [27] A review of recent advancements of variable refrigerant flow air-conditioning systems
    Wan, Hanlong
    Cao, Tao
    Hwang, Yunho
    Oh, Saikee
    APPLIED THERMAL ENGINEERING, 2020, 169
  • [28] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT B, 2012, 24 : 1248 - 1254
  • [29] Direct Feedback Linearization Based Control in Variable Air Volume air-conditioning System
    Shi, Zhigang
    Li, Xuquan
    Hu, Songtao
    2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL III, 2010, : 248 - 251
  • [30] Thermoelectric Air-Conditioning System: Building Applications and Enhancement Techniques
    Baheta, Aklilu Tesfamichael
    Looi, Kar Kin
    Oumer, Ahmed Nurye
    Habib, Khairul
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2019, 27 (02)