Research on linear active disturbance rejection control strategy based on grid-forming inverters

被引:0
|
作者
Hu, Meng Jie [1 ]
Tang, Yu [1 ]
机构
[1] Hebei Univ Technol, Sch Elect Engn, State Key Lab Reliabil & Intelligence Elect Equipm, Tianjin 300130, Peoples R China
关键词
anti-interference; grid-forming inverter; harmonic suppression; linear active disturbance rejection control; CONNECTED INVERTER; STABILITY ANALYSIS; IMPEDANCE; SYNCHRONIZATION; FREQUENCY; OPERATION; DESIGN;
D O I
10.1002/cta.4186
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Grid-forming inverters play a vital role in connecting renewable energy sources to the grid, and maintaining stable output voltage is essential for system operation. However, traditional dual-PI voltage-current loop control suffers from slow response and weak disturbance rejection, leading to suboptimal control performance of grid-connected inverter output voltage. Moreover, employing traditional dual-PI control in grid-connected inverters results in low output impedance, making them prone to subsynchronous oscillations and instability under strong grid conditions. To address these challenges, this study introduces a novel dual-loop control strategy based on linear active disturbance rejection control (LADRC), wherein voltage loop is regulated by LADRC while current loop employs PI control. Quantitative analysis and experimental findings demonstrate that compared with traditional dual-PI voltage-current loop control, the LADRC-based dual-loop control strategy offers higher bandwidth and lower steady-state error, thereby enhancing the tracking speed and precision of grid-forming inverter output voltage. The LADRC-based dual-loop control strategy reduces output impedance in grid-forming inverter systems, lowering THD of output voltage and improving harmonic suppression under nonlinear loads. Experimental results show its robustness against strong grid conditions compared with traditional dual-PI control, ensuring stable output voltage. The study introduces a novel dual-loop control strategy for grid-connected inverters, integrating linear active disturbance rejection control (LADRC) for voltage regulation and proportional-integral (PI) control for current regulation. Analysis reveals that the LADRC-based strategy enhances bandwidth, reduces steady-state error, and diminishes the equivalent output impedance of grid-forming inverter systems, thereby improving tracking speed, precision, and harmonic suppression capability under nonlinear loads. Furthermore, the strategy enhances the robustness of grid-forming inverters under strong grid conditions, ensuring stability and dynamic performance of the output voltage. image
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Direct AC voltage control for grid-forming inverters
    Qoria, Taoufik
    Li, Chuanyue
    Oue, Ko
    Gruson, Francois
    Colas, Frederic
    Guillaud, Xavier
    JOURNAL OF POWER ELECTRONICS, 2020, 20 (01) : 198 - 211
  • [22] A Scalable Control Design for Grid-Forming Inverters in Microgrids
    Watson, Jeremy D.
    Ojo, Yemi
    Laib, Khaled
    Lestas, Ioannis
    IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (06) : 4726 - 4739
  • [23] Continuous Abstraction Modelling and Control of Grid-Forming Inverters
    Firouzmand, Elnaz
    Farokhi, Farhad
    Sharifi, Iman
    Talebi, H. A.
    2024 IEEE 9TH SOUTHERN POWER ELECTRONICS CONFERENCE, SPEC, 2024,
  • [24] Grid-Forming Converter with Improved Dynamic and Disturbance Rejection Capability
    dos Santos Serra, Amiron Wolff
    de Souza Ribeiro, Luiz Antonio
    Savaghebi, Mehdi
    IEEE 15TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS, PEDG 2024, 2024,
  • [25] Research on an electronic differential control strategy based on active disturbance rejection control
    Yao F.
    Zhao X.
    Wu Z.
    Lin X.
    Zheng S.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (03): : 177 - 191
  • [26] Improved Active Disturbance Rejection Control Strategy for LCL-Type Grid-Connected Inverters Based on the Backstepping Method
    Zhang, Zhiru
    Ding, Wenfang
    ELECTRONICS, 2022, 11 (14)
  • [27] Disturbance Rejection Control of Grid-Forming Inverter for Line Impedance Parameter Perturbation in Weak Power Grid
    Huang, Mayue
    Li, Hui
    ELECTRONICS, 2024, 13 (10)
  • [28] Multivariable Control Design for Grid-Forming Inverters With Decoupled Active and Reactive Power Loops
    Rathnayake, Dayan Bandara
    Bahrani, Behrooz
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 1635 - 1649
  • [29] Coordinated control of active disturbance rejection and grid voltage feedforward for grid-connected inverters
    Zhong, Guang-Xin
    Wang, Zhiteng
    Zhou, Jiahua
    Li, Jian
    Su, Qingyu
    IET POWER ELECTRONICS, 2022,
  • [30] Islanding Detection of Grid-Forming Inverters
    Liu, Teng
    Wang, Xiongfei
    Liu, Fangcheng
    Xin, Kai
    Liu, Yunfeng
    IEEE ELECTRIFICATION MAGAZINE, 2022, 10 (01): : 30 - 38