MR Cranial Bone Imaging: Evaluation of Both Motion-Corrected and Automated Deep Learning Pseudo-CT Estimated MR Images

被引:2
|
作者
Linkugel, Andrew D. [1 ]
Wang, Tongyao [2 ]
Boroojeni, Parna Eshraghi [2 ]
Eldeniz, Cihat [2 ]
Chen, Yasheng [3 ]
Skolnick, Gary B. [1 ]
Commean, Paul K. [2 ]
Merrill, Corinne M. [1 ]
Strahle, Jennifer M. [4 ]
Goyal, Manu S. [2 ]
An, Hongyu [2 ,3 ]
Patel, Kamlesh B. [1 ]
机构
[1] Washington Univ, Div Plast & Reconstruct Surg, 660 South Euclid Ave,Campus Box 8238, St. Louis, MO 63110 USA
[2] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[3] Washington Univ, Dept Neurol, St Louis, MO 63110 USA
[4] Washington Univ, Dept Neurosurg, St Louis, MO 63110 USA
基金
美国国家卫生研究院;
关键词
D O I
10.3174/ajnr.A8335
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT imaging exposes patients to ionizing radiation. MR imaging is radiation free but previously has not been able to produce diagnostic-quality images of bone on a timeline suitable for clinical use. We developed automated motion correction and use deep learning to generate pseudo-CT images from MR images. We aim to evaluate whether motion-corrected pseudo-CT produces cranial images that have potential to be acceptable for clinical use. MATERIALS AND METHODS: Patients younger than age 18 who underwent CT imaging of the head for either trauma or evaluation of cranial suture patency were recruited. Subjects underwent a 5-minute golden-angle stack-of-stars radial volumetric interpolated breath-hold MR image. Motion correction was applied to the MR imaging followed by a deep learning-based method to generate pseudo-CT images. CT and pseudo-CT images were evaluated and, based on indication for imaging, either presence of skull fracture or cranial suture patency was first recorded while viewing the MR imaging-based pseudo-CT and then recorded while viewing the clinical CT. RESULTS: A total of 12 patients underwent CT and MR imaging to evaluate suture patency, and 60 patients underwent CT and MR imaging for evaluation of head trauma. For cranial suture patency, pseudo-CT had 100% specificity and 100% sensitivity for the identification of suture closure. For identification of skull fractures, pseudo-CT had 100% specificity and 90% sensitivity. CONCLUSIONS: Our early results show that automated motion-corrected and deep learning-generated pseudo-CT images of the pediatric skull have potential for clinical use and offer a high level of diagnostic accuracy when compared with standard CT scans.
引用
收藏
页码:1284 / 1290
页数:7
相关论文
共 12 条
  • [1] Deep-learning synthesized pseudo-CT for MR high-resolution pediatric cranial bone imaging (MR-HiPCB)
    Boroojeni, Parna Eshraghi
    Chen, Yasheng
    Commean, Paul K.
    Eldeniz, Cihat
    Skolnick, Gary B.
    Merrill, Corinne
    Patel, Kamlesh B.
    An, Hongyu
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2285 - 2297
  • [2] Automated detection of motion artifacts in brain MR images using deep learning
    Jimeno, Marina Manso
    Ravi, Keerthi Sravan
    Fung, Maggie
    Oyekunle, Dotun
    Ogbole, Godwin
    Vaughan Jr, John Thomas
    Geethanath, Sairam
    NMR IN BIOMEDICINE, 2025, 38 (01)
  • [3] Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction
    Torrado-Carvajal, Angel
    Vera-Olmos, Javier
    Izquierdo-Garcia, David
    Catalano, Onofrio A.
    Morales, Manuel A.
    Margolin, Justin
    Soricelli, Andrea
    Salvatore, Marco
    Malpica, Norberto
    Catana, Ciprian
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) : 429 - 435
  • [4] Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis
    Getzmann, Jonas M.
    Deininger-Czermak, Eva
    Melissanidis, Savvas
    Ensle, Falko
    Kaushik, Sandeep S.
    Wiesinger, Florian
    Cozzini, Cristina
    Sconfienza, Luca M.
    Guggenberger, Roman
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [5] Pseudo-CT Generation from MRI Images for Bone Lesion Detection Using Deep Learning Approach
    Sreeja, S.
    Mubarak, D. Muhammad Noorul
    PERVASIVE COMPUTING AND SOCIAL NETWORKING, ICPCSN 2022, 2023, 475 : 621 - 632
  • [6] Radiotherapy-Specific Imaging Prior Knowledge and Its Impact in Deep Learning Based Cranial Pseudo-CT Generation
    Law, M.
    Yuan, J.
    Lo, G.
    Wong, O.
    Zhou, Y.
    Yu, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E510 - E510
  • [7] Clinical evaluation of self-learning GAN based pseudo-CT generation software for low field pelvic MR
    Fenoglietto, P.
    Gevaert, T.
    Boussaer, M.
    Delasalles, E.
    Ioannidou, D.
    Shreshtha, K.
    Roque, T.
    Paragios, N.
    Azria, D.
    Ozyar, E.
    Gungor, G.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S583 - S584
  • [8] A robust two-step deep learning method for pseudo-CT generation for PET-MR attenuation correction in brain
    Krokos, G.
    Mackewn, J.
    Yakub, S.
    Srinivasan, R.
    Jeljeli, S.
    Kinsella, S.
    Marsden, P. K.
    Hammers, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S131 - S131
  • [9] Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction (vol 60, pg 429, 2019)
    Torrado-Carvajal, Angel
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (01) : 161 - 161
  • [10] Synthetic temporal bone CT generation from UTE-MRI using a cycleGAN-based deep learning model: advancing beyond CT-MR imaging fusion
    You, Sung-Hye
    Cho, Yongwon
    Kim, Byungjun
    Kim, Jeeho
    Im, Gi Jung
    Park, Euyhyun
    Kim, Inseong
    Kim, Kyung Min
    Kim, Bo Kyu
    EUROPEAN RADIOLOGY, 2025, 35 (01) : 38 - 48