Patient-specific mechanical analysis of pedicle screw insertion in simulated osteoporotic spinal bone models derived from medical images

被引:0
|
作者
Nishida, Norihiro [1 ]
Suzuki, Hidenori [1 ]
Tetsu, Hanvey [2 ]
Morishita, Yuki [2 ]
Kumaran, Yogesh [3 ,4 ]
Jiang, Fei [2 ]
Funaba, Masahiro [1 ]
Fujimoto, Kazuhiro [1 ]
Ichihara, Yusuke [1 ]
Sakai, Takashi [1 ]
Ohgi, Junji [2 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Dept Orthopaed Surg, 1-1-1 Minami Kogushi, Ube, Yamaguchi 7558505, Japan
[2] Yamaguchi Univ, Fac Engn, Ube, Japan
[3] Univ Toledo, Engn Ctr Orthopaed Res Excellence, Dept Bioengn, Toledo, OH USA
[4] Univ Toledo, Dept Orthopaed, Toledo, OH USA
关键词
Printing; Three-dimensional; Pedicle screw; Mechanical tests; Spine; Torque; FIXATION; SURGERY; TORQUE;
D O I
10.31616/asj.2024.0121
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Biomechanical study. Purpose: To investigate the mechanical characteristics of bone models created from medical images. Overview of Literature: Recent advancements in three-dimensional (3D) printing technology have affected its application in surgery. However, a notable gap exists in the analyses of how patient's dimorphism and variations in vertebral body anatomy influence the maximum insertional torque (MIT) and pullout strength (POS) of pedicle screws (PS) in osteoporotic vertebral bone models derived from medical images. Methods: Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine's crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure. Results: The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes. Conclusions: The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] CT-based Patient-specific Simulation Software for Pedicle Screw Insertion
    Klein, Shawn
    Whyne, Cari M.
    Rush, Raphael
    Ginsberg, Howard J.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (07): : 502 - 506
  • [2] Safe and Accurate Midcervical Pedicle Screw Insertion Procedure With the Patient-Specific Screw Guide Template System
    Kaneyama, Shuichi
    Sugawara, Taku
    Sumi, Masatoshi
    SPINE, 2015, 40 (06) : E341 - E348
  • [3] Patient-Specific Finite Element Models of Posterior Pedicle Screw Fixation: Effect of Screw's Size and Geometry
    Sensale, Marco
    Vendeuvre, Tanguy
    Schilling, Christoph
    Grupp, Thomas
    Rochette, Michel
    Dall'Ara, Enrico
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [4] Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion An Analysis of 76 Cervical and Thoracic Screw Trajectories
    Pijpker, Peter A. J.
    Kraeima, Joep
    Witjes, Max J. H.
    Oterdoom, D. L. Marinus
    Vergeer, Rob A.
    Coppes, Maarten H.
    Groen, Rob J. M.
    Kuijlen, Jos M. A.
    SPINE, 2021, 46 (03) : 160 - 168
  • [5] Symbolic regression metamodel-based optimal design of patient-specific spinal implant (pedicle screw fixation)
    Biswas, Jayanta Kumar
    Kalita, Kanak
    Roychowdhury, Amit
    ENGINEERING WITH COMPUTERS, 2022, 38 (02) : 999 - 1014
  • [6] Symbolic regression metamodel-based optimal design of patient-specific spinal implant (pedicle screw fixation)
    Jayanta Kumar Biswas
    Kanak Kalita
    Amit Roychowdhury
    Engineering with Computers, 2022, 38 : 999 - 1014
  • [7] Outcome and safety analysis of 3D-printed patient-specific pedicle screw jigs for complex spinal deformities: a comparative study
    Garg, Bhavuk
    Gupta, Manish
    Singh, Menaka
    Kalyanasundaram, Dinesh
    SPINE JOURNAL, 2019, 19 (01): : 56 - 64
  • [8] Accuracy of a patient-specific template for pedicle screw placement compared with a conventional method: a meta-analysis
    Yong Fan
    Jin-Peng Du
    Qi-Ning Wu
    Jia-Nan Zhang
    Ding-Jun Hao
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1641 - 1649
  • [9] Accuracy of a patient-specific template for pedicle screw placement compared with a conventional method: a meta-analysis
    Fan, Yong
    Du, Jin-Peng
    Wu, Qi-Ning
    Zhang, Jia-Nan
    Hao, Ding-Jun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1641 - 1649
  • [10] Multistep pedicle screw insertion procedure with patient-specific lamina fit-and-lock templates for the thoracic spine Clinical article
    Sugawara, Taku
    Higashiyama, Naoki
    Kaneyama, Shuichi
    Takabatake, Masato
    Watanabe, Naoko
    Uchida, Fujio
    Sumi, Masatoshi
    Mizoi, Kazuo
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (02) : 185 - 190