Thermal comfort investigation of membrane-assisted radiant cooling in outdoor settings

被引:4
|
作者
Yang, Junran [1 ]
Liang, Yan [1 ]
Zhong, Ziwen [2 ]
Dharmasastha, K. [1 ]
Xie, Yongxin [1 ]
Niu, Jian- Lei [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Kowloon, Hong Kong, Peoples R China
[2] Shenzhen Polytech Univ, Sch Mech & Elect Engn, Shenzhen, Peoples R China
关键词
Local radiant cooling; Outdoor thermal comfort; Thermal sensation votes; Thermal comfort votes; Urban microclimate; URBAN HEAT-ISLAND; ENVIRONMENTAL-CONDITIONS; CLIMATE; IMPACT; SENSATION; SPACES;
D O I
10.1016/j.scs.2024.105634
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The global warming and urban heat island effect call for mitigation strategies for improving thermal environments in open urban spaces. Radiant cooling can remove heat from the human body via direct thermal radiation, thereby creating the possibility to provide active cooling for people in outdoor environments. While using a transparent membrane, convection energy lost to the ambient airflow can be minimized. However, current research on the thermal comfort of radiant cooling systems is restricted to indoor applications, while outdoor applications remain unclear. To address this need, the study investigated the effect of membrane-assisted asymmetric radiant cooling on people's thermal perception in outdoor environments. A radiant cooling facility in an outdoor setting was built, and its cooling effects were assessed by using 248 human subjects across hot and transitional seasons. It is found that the radiant cooling facility can lower the mean thermal sensation vote (MTSV) by 0.6 to 1.5 units. The degree of cooling depends both on the panel temperature and environmental conditions. At the panel surface temperature of 14.3 degrees C, MTSV was at the neutral zone (-0.5 <= MTSV <= 0.5) with the environmental UTCI as high as 38.1 degrees C, whereas the thermal sensation of the group without radiant cooling was rated warm to hot. Under this condition, the ambient UTCI scope of no heat stress can be extended by 10.1 degrees C higher. The strongest local cooling sensation appeared in the back, with an average decrease of 1.33 units in MTSV, contributing to lowering the overall thermal sensation of the body. For the first time, it is demonstrated that membrane-assisted radiant cooling panels can effectively improve thermal comfort in open outdoor settings.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Performance of radiant cooling surfaces with respect to energy consumption and thermal comfort
    Oxizidis, Simos
    Papadopoulos, Agis M.
    ENERGY AND BUILDINGS, 2013, 57 : 199 - 209
  • [22] Investigation into sensitivities of factors in outdoor thermal comfort indices
    Fang, Zhaosong
    Lin, Zhang
    Mak, Cheuk Ming
    Niu, Jianlei
    Tse, Kam-Tim
    BUILDING AND ENVIRONMENT, 2018, 128 : 129 - 142
  • [23] INVESTIGATION OF OUTDOOR THERMAL COMFORT IN HOT AND HUMID ENVIRONMENT
    Cheng, Ming-Jen
    Lo, Jen-Hao
    Hwang, Ruey-Lung
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1086 - 1094
  • [24] Investigation of the outdoor workers' thermal comfort and improving technology
    Yang, Jiahao
    Fan, Yini
    Wu, Zhuotong
    Luo, Xinyi
    Gao, Naipin
    Fang, Zhaosong
    Wu, Peihao
    ENERGY AND BUILDINGS, 2025, 331
  • [25] Investigation of PMV Model for Evaluation of the Outdoor Thermal Comfort
    Fang, Zhaosong
    Feng, Xiwen
    Lin, Zhang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2457 - 2462
  • [26] Comparison of different methods of estimating the mean radiant temperature in outdoor thermal comfort studies
    Krueger, E. L.
    Minella, F. O.
    Matzarakis, A.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2014, 58 (08) : 1727 - 1737
  • [27] Comparison of different methods of estimating the mean radiant temperature in outdoor thermal comfort studies
    E. L. Krüger
    F. O. Minella
    A. Matzarakis
    International Journal of Biometeorology, 2014, 58 : 1727 - 1737
  • [28] Radiant Cooling with Dehumidified Air Ventilation for Thermal Comfort in Buildings in Tropical Climate
    Nutprasert, Nipaporn
    Chaiwiwatworakul, Pipat
    2013 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES (2013 AEDCEE), 2014, 52 : 250 - 259
  • [29] Hydronic flow path analysis on the thermal comfort performance of radiant cooling system
    Dharmasastha, K.
    Nagendra, S. M. Shiva
    Maiya, M. P.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 39
  • [30] Subjective assessment of thermal comfort by radiant cooling in a tropical hot humid climate
    Aryal, Ashmin
    Chaiwiwatworakul, Pipat
    Chirarattananon, Surapong
    Wongsuwan, Wipawadee
    ENERGY AND BUILDINGS, 2022, 254