摘要
Operating a chemical detector system at a stand-off distance from a hazard is advantageous. By increasing the distance between the detector and the hazard, the risk of contamination decreases, whilst increasing personnel safety. The aim of this work is to develop an optical bench mounted system for presumptive identification of toxic chemical simulants at a stand-off distance. Unlike commercially available instruments, the Dstl system is not a light tight unit, but instead offers a platform in which different optical sub-components can be tested in an attempt to optimise the overall sensitivity of the system. By operating in a pulsed mode, not only is detector noise reduced but also the background radiation due to laboratory light. To test its performance, the Dstl Raman system was assessed at a stand-off distance of 2 m and collected spectra from Raman standard materials. Additional work was conducted with the Dstl Raman system to collect spectra from toxic chemicals associated with chemical warfare agents (CWAs). Indicative comparisons were made against data collected on commercially available systems, in order to identify future development for the Dstl system. Overall, this research piece aimed to exploit the powerful discriminatory nature of the Raman technique whilst demonstrating it under room lights and at useful stand-off distances. The Dstl stand-off Raman system performed well and provided clean spectra for the CWA simulant study. However all the tests reported here were measured on bulk samples and further work is needed to determine how the system performs against samples deposited as thin layers on realistic substrates
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Research focuses on 'stand-off' bomb detection
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (08) : VI - VI
  • [42] Stand-off and up-close Raman detection of nitrates buried in sand and soils
    Farley, Carlton, III
    Sadate, Sandra
    Kassu, Aschalew
    Monono, Belther
    Witt, William
    Bibb, Jonathan
    Sharma, Anup
    INFRARED REMOTE SENSING AND INSTRUMENTATION XXII, 2014, 9219
  • [43] Portable Stand-Off Time-Gated Raman Spectroscopy for Detection of Explosive Precursor
    Ren, Wenzhen
    Wang, Hui
    Xie, Zhengmao
    Zhu, Xiangping
    Zhang, Pu
    Wang, Bo
    Huang, Cheng
    Xu, Dandan
    Zhao, Wei
    JOURNAL OF APPLIED SPECTROSCOPY, 2024, 91 (04) : 953 - 960
  • [44] Portable Raman device for detection of chemical and biological warfare agents
    Wabuyele, MB
    Martin, ME
    Yan, F
    Stokes, DL
    Mobley, J
    Cullum, BM
    Wintenberg, A
    Lenarduzzi, R
    Vo-Dinh, T
    Advanced Biomedical and Clinical Diagnostic Systems III, 2005, 5692 : 330 - 336
  • [45] MAGNETIC FIELD EFFECTS ON BOW SHOCK STAND-OFF DISTANCE
    ZIEMER, RW
    BUSH, WB
    PHYSICAL REVIEW LETTERS, 1958, 1 (02) : 58 - 59
  • [46] Multispectral analysis of biological agents to implement a quick tool for stand-off biological detection
    Carestia, M.
    Pizzoferrato, R.
    Lungaroni, M.
    Gabriele, J.
    Ludovici, G. M.
    Cenciarelli, O.
    Gelfusa, M.
    Murari, A.
    Malizia, A.
    Gaudio, P.
    OPTICS AND PHOTONICS FOR COUNTERTERRORISM, CRIME FIGHTING, AND DEFENCE XI; AND OPTICAL MATERIALS AND BIOMATERIALS IN SECURITY AND DEFENCE SYSTEMS TECHNOLOGY XII, 2015, 9652
  • [47] Bow shock stand-off distance for subsonic decelerating bodies
    H. Roohani
    I. M. A. Gledhill
    I. Mahomed
    B. W. Skews
    Shock Waves, 2020, 30 : 115 - 129
  • [48] Effect of Conical Free Stream on Shock Stand-Off Distance
    Hornung, H. G.
    AIAA JOURNAL, 2019, 57 (09) : 4115 - 4116
  • [49] Fluorescence/depolarization lidar for mid-range stand-off detection of biological agents
    Mierczyk, Z.
    Kopczynski, K.
    Zygmunt, M.
    Wojtanowski, J.
    Mlynczak, J.
    Gawlikowski, A.
    Mlodzianko, A.
    Piotrowski, W.
    Gietka, A.
    Knysak, P.
    Drozd, T.
    Muzal, M.
    Kaszczuk, M.
    Ostrowski, R.
    Jakubaszek, M.
    LASER RADAR TECHNOLOGY AND APPLICATIONS XVI, 2011, 8037
  • [50] Effect of conical free stream on shock stand-off distance
    Hornung, H.G.
    AIAA Journal, 2019, 57 (09): : 4115 - 4116