Improving Raman stand-off distance for the detection of chemical warfare agents

被引:0
|
作者
Davies, Samantha [1 ]
Curtis, Kelly [2 ]
Mcewan, Ken [2 ]
机构
[1] Dstl Porton Down, Chem Biol & Radiat Div, Salisbury SP4 0JQ, Wilts, England
[2] Dstl Porton Down, Cyber & Informat Syst Div, Salisbury SP4 0JQ, Wilts, England
关键词
Raman spectroscopy; chemical warfare agents; stand-off detection;
D O I
10.1117/12.3014374
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Operating a chemical detector system at a stand-off distance from a hazard is advantageous. By increasing the distance between the detector and the hazard, the risk of contamination decreases, whilst increasing personnel safety. The aim of this work is to develop an optical bench mounted system for presumptive identification of toxic chemical simulants at a stand-off distance. Unlike commercially available instruments, the Dstl system is not a light tight unit, but instead offers a platform in which different optical sub-components can be tested in an attempt to optimise the overall sensitivity of the system. By operating in a pulsed mode, not only is detector noise reduced but also the background radiation due to laboratory light. To test its performance, the Dstl Raman system was assessed at a stand-off distance of 2 m and collected spectra from Raman standard materials. Additional work was conducted with the Dstl Raman system to collect spectra from toxic chemicals associated with chemical warfare agents (CWAs). Indicative comparisons were made against data collected on commercially available systems, in order to identify future development for the Dstl system. Overall, this research piece aimed to exploit the powerful discriminatory nature of the Raman technique whilst demonstrating it under room lights and at useful stand-off distances. The Dstl stand-off Raman system performed well and provided clean spectra for the CWA simulant study. However all the tests reported here were measured on bulk samples and further work is needed to determine how the system performs against samples deposited as thin layers on realistic substrates
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Stand-off Spectroscopy for the Detection of Chemical Warfare Agents
    Clewes, Rhea J.
    Howle, Chris R.
    Stothard, David J. M.
    Dunn, Malcolm H.
    Robertson, Gordon
    Miller, William
    Malcolm, Graeme
    Maker, Gareth
    Cox, Rick
    Williams, Brad
    Russell, Matt
    OPTICS AND PHOTONICS FOR COUNTERTERRORISM, CRIME FIGHTING, AND DEFENCE VIII, 2012, 8546
  • [2] Stand-off tissue-based biosensors for the detection of chemical warfare agents using photosynthetic fluorescence induction
    Sanders, CA
    Rodriguez, M
    Greenbaum, E
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (7-8): : 439 - 446
  • [3] Infrared differential absorption lidar for stand-off detection of chemical agents
    Razdan, A. K.
    Veerabuthiran, S.
    Jindal, M. K.
    Sharma, R. K.
    PRAMANA-JOURNAL OF PHYSICS, 2014, 82 (02): : 385 - 389
  • [4] Infrared differential absorption lidar for stand-off detection of chemical agents
    A K RAZDAN
    S VEERABUTHIRAN
    M K JINDAL
    R K SHARMA
    Pramana, 2014, 82 : 385 - 389
  • [5] Miniaturized spectrometer for stand-off chemical detection
    Henning, PF
    Chadha, S
    Damren, R
    Rowe, R
    Stevenson, C
    Curtiss, LE
    DiGiuseppe, T
    INSTRUMENTATION FOR AIR POLLUTION AND GLOBAL ATMOSPHERIC MONITORING, 2002, 4574 : 37 - 43
  • [6] Stand-off Raman spectroscopy
    Hobro, Alison J.
    Lendl, Bernhard
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (11) : 1235 - 1242
  • [7] Stand-off detection of chemicals by UV Raman spectroscopy
    Wu, M
    Ray, M
    Fung, KH
    Ruckman, MW
    Harder, D
    Sedlacek, AJ
    APPLIED SPECTROSCOPY, 2000, 54 (06) : 800 - 806
  • [8] Characteristics of Raman spectrum from stand-off detection
    Zhang Li
    Zheng Hai-Yang
    Wang Ying-Ping
    Ding Lei
    Fang Li
    ACTA PHYSICA SINICA, 2016, 65 (05)
  • [9] Raman Scattering for explosive traces stand-off detection
    Garibbo, A.
    Palucci, A.
    Chirico, R.
    2014 THIRD MEDITERRANEAN PHOTONICS CONFERENCE, 2014,
  • [10] Differential absorption radiometry for stand-off chemical detection
    Laufer, G
    CHEMICAL AND BIOLOGICAL SENSING II, 2001, 4378 : 60 - 70