Privacy-Protected Contactless Sleep Parameters Measurement Using a Defocused Camera

被引:1
|
作者
Zhu, Yingen [1 ]
Hong, Hong [2 ]
Wang, Wenjin [1 ]
机构
[1] Southern Univ Sci & Technol, Dept Biomed Engn, Shenzhen 518055, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Nanjing 210094, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Sleep apnea; Cameras; Monitoring; Optical variables measurement; Biomedical measurement; Biomedical monitoring; Privacy; Contactless sensing; defocused camera; privacy protection; sleep monitoring;
D O I
10.1109/JBHI.2024.3396397
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Sleep monitoring plays a vital role in various scenarios such as hospitals and living-assisted homes, contributing to the prevention of sleep accidents as well as the assessment of sleep health. Contactless camera-based sleep monitoring is promising due to its user-friendly nature and rich visual semantics. However, the privacy concern of video cameras limits their applications in sleep monitoring. In this paper, we explored the opportunity of using a defocused camera that does not allow identification of the monitored subject when measuring sleep-related parameters, as face detection and recognition are impossible on optically blurred images. We proposed a novel privacy-protected sleep parameters measurement framework, including a physiological measurement branch and a semantic analysis branch based on ResNet-18. Four important sleep parameters are measured: heart rate (HR), respiration rate (RR), sleep posture, and movement. The results of HR, RR, and movement have strong correlations with the reference (HR: R = 0.9076; RR: R = 0.9734; Movement: R = 0.9946). The overall mean absolute errors (MAE) for HR and RR are 5.2 bpm and 1.5 bpm respectively. The measurement of HR and RR achieve reliable estimation coverage of 72.1% and 93.6%, respectively. The sleep posture detection achieves an overall accuracy of 94.5%. Experimental results show that the defocused camera is promising for sleep monitoring as it fundamentally eliminates the privacy issue while still allowing the measurement of multiple parameters that are essential for sleep health informatics.
引用
收藏
页码:4660 / 4673
页数:14
相关论文
共 31 条
  • [21] A Privacy Protected Sleep Quality Prediction Approach Using Ultrawideband Ambient Sensor, Synthetic Data, and Deep Learning
    Uddin, Md Zia
    PROCEEDINGS OF THE 2024 9TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING TECHNOLOGIES, ICMLT 2024, 2024, : 58 - 63
  • [22] Contactless Body Measurement System Using Single Fixed-Point RGBD Camera Based on Pose Graph Reconstruction
    Cherdchusakulchai, Riu
    Thoumrungroje, Sucharn
    Tungpanjasil, Thanyaporn
    Pimpin, Alongkorn
    Srituravanich, Werayut
    Damrongplasit, Nattapol
    IEEE ACCESS, 2024, 12 : 84363 - 84373
  • [23] Joint calibration of an inertial measurement unit and coordinate transformation parameters using a monocular camera
    Zachariah, Dave
    Jansson, Magnus
    2010 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION, 2010,
  • [24] PD-Gait: Contactless and privacy-preserving gait measurement of Parkinson's disease patients using acoustic signals
    Li, Zeshui
    Pan, Yang
    Dai, Haipeng
    Zhang, Wenhao
    Li, Zhen
    Wang, Wei
    Chen, Guihai
    SOFTWARE-PRACTICE & EXPERIENCE, 2024, 54 (09): : 1733 - 1753
  • [25] Key Parameters for Maize Leaf Moisture Measurement Using NIR Camera With Filters Based on Hyperspectral Data
    Li Peng-cheng
    Liu Han
    Zhao Long-lian
    Li Jun-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (10) : 3184 - 3188
  • [26] Measurement of the movement parameters of saltating sand over a flat sand bed using a high-speed digital camera
    Jiang, Chanwen
    Dong, Zhibao
    Zhang, Zhengcai
    ENVIRONMENTAL EARTH SCIENCES, 2015, 74 (06) : 4865 - 4874
  • [27] Measurement of the movement parameters of saltating sand over a flat sand bed using a high-speed digital camera
    Chanwen Jiang
    Zhibao Dong
    Zhengcai Zhang
    Environmental Earth Sciences, 2015, 74 : 4865 - 4874
  • [29] Contactless measurement of electrical parameters and estimation of current-voltage characteristics of Si solar cells using the illumination intensity dependence of lock-in carrierography (photoluminescence) images
    Liu, Junyan
    Melnikov, Alexander
    Mandelis, Andreas
    JOURNAL OF APPLIED PHYSICS, 2013, 114 (10)
  • [30] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY FOR MEASUREMENT OF PARAMETERS OF RESPIRATORY-FUNCTION DURING SLEEP IN LAMBS USING THE SINGLE POSITION GRAPHIC TECHNIQUE
    WARREN, RH
    ALDERSON, SH
    FEWELL, JE
    CLINICAL RESEARCH, 1986, 34 (01): : A263 - A263