Exploring the relationship between 24-2 visual field and widefield optical coherence tomography data across healthy, glaucoma suspect and glaucoma eyes

被引:1
|
作者
Tong, Janelle [1 ,2 ,3 ]
Phu, Jack [1 ,2 ,3 ,4 ,5 ]
Alonso-Caneiro, David [6 ,7 ]
Kugelman, Jason [7 ]
Khuu, Sieu [2 ]
Agar, Ashish [8 ]
Coroneo, Minas [8 ]
Kalloniatis, Michael [2 ,3 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Deakin Univ, Sch Med Optometry, Waurn Ponds, Vic 3216, Australia
[4] Univ Sydney, Fac Med, Sydney, NSW, Australia
[5] Concord Repatriat Gen Hosp, Concord Clin Sch, Sydney, NSW, Australia
[6] Univ Sunshine Coast, Sch Sci Technol & Engn, Sunshine Coast, Qld, Australia
[7] Queensland Univ Technol, Ctr Vis & Eye Res, Sch Optometry & Vis Sci, Kelvin Grove, Qld, Australia
[8] Univ New South Wales, Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
glaucoma; optical coherence tomography; visual fields; STANDARD AUTOMATED PERIMETRY; FIBER BUNDLE TRAJECTORIES; FULL THRESHOLD; SPATIAL SUMMATION; GANGLION-CELLS; OCULAR SHAPE; MODEL; SENSITIVITY; VARIABILITY; DEFECTS;
D O I
10.1111/opo.13368
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To utilise ganglion cell-inner plexiform layer (GCIPL) measurements acquired using widefield optical coherence tomography (OCT) scans spanning 55 degrees x 45 degrees to explore the link between co-localised structural parameters and clinical visual field (VF) data. Methods: Widefield OCT scans acquired from 311 healthy, 268 glaucoma suspect and 269 glaucoma eyes were segmented to generate GCIPL thickness measurements. Estimated ganglion cell (GC) counts, calculated from GCIPL measurements, were plotted against 24-2 SITA Faster visual field (VF) thresholds, and regression models were computed with data categorised by diagnosis and VF status. Classification of locations as VF defective or non-defective using GCIPL parameters computed across eccentricity- and hemifield-dependent clusters was assessed by analysing areas under receiver operating characteristic curves (AUROCCs). Sensitivities and specificities were calculated per diagnostic category. Results: Segmented linear regression models between GC counts and VF thresholds demonstrated higher variability in VF defective locations relative to non-defective locations (mean absolute error 6.10-9.93 dB and 1.43-1.91 dB, respectively). AUROCCs from cluster-wide GCIPL parameters were similar across methods centrally (p = 0.06-0.84) but significantly greater peripherally, especially when considering classification of more central locations (p < 0.0001). Across diagnoses, cluster-wide GCIPL parameters demonstrated variable sensitivities and specificities (0.36-0.93 and 0.65-0.98, respectively), with the highest specificities observed across healthy eyes (0.73-0.98). Conclusions: Quantitative prediction of VF thresholds from widefield OCT is affected by high variability at VF defective locations. Prediction of VF status based on cluster-wide GCIPL parameters from widefield OCT could become useful to aid clinical decision-making in appropriately targeting VF assessments.
引用
收藏
页码:1484 / 1499
页数:16
相关论文
共 50 条
  • [31] Simultaneously performed combined 24-2 and 10-2 visual field tests in glaucoma
    Jung, Kyoung In
    Ryu, Hee Kyung
    Hong, Ki Hoon
    Kim, Yong Chan
    Park, Chan Kee
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [32] Optical coherence tomography angiography in glaucoma: analysis of the vessel density-visual field sensitivity relationship
    Hollo, Gabor
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (18)
  • [33] Simultaneously performed combined 24-2 and 10-2 visual field tests in glaucoma
    Kyoung In Jung
    Hee Kyung Ryu
    Ki Hoon Hong
    Yong Chan Kim
    Chan Kee Park
    Scientific Reports, 11
  • [34] Changes in glaucoma management following visual field testing and optical coherence tomography
    Sun, Michelle T.
    Singh, Kuldev
    Wang, Sophia Y.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (08) : 1119 - 1124
  • [35] Comparison of the 24-2 and 24-2C Visual Field Grids in Determining the Macular Structure-Function Relationship in Glaucoma
    Hong, Ji Wook
    Baek, Min Su
    Lee, Jin Yeong
    Song, Min Kyung
    Shin, Joong Won
    Kook, Michael S.
    JOURNAL OF GLAUCOMA, 2021, 30 (10) : 887 - 894
  • [36] Performance of the 10-2 and 24-2 Visual Field Tests for Detecting Central Visual Field Abnormalities in Glaucoma
    Wu, Zhichao
    Medeiros, Felipe A.
    Weinreb, Robert N.
    Zangwill, Linda M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 196 : 10 - 17
  • [37] Value of 10-2 Visual Field Testing in Glaucoma Patients with Early 24-2 Visual Field Loss
    West, Michael E.
    Sharpe, Glen P.
    Hutchison, Donna M.
    Rafuse, Paul E.
    Shuba, Lesya M.
    Nicolela, Marcelo T.
    Vianna, Jayme R.
    Chauhan, Balwantray C.
    OPHTHALMOLOGY, 2021, 128 (04) : 545 - 553
  • [38] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Chingwei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (01) : 80 - 87
  • [39] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Jain, Kanika
    Pegu, Julie
    Bhoot, Madhu
    Dubey, Suneeta
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E131 - E132
  • [40] Foveal Avascular Zone Measurement Via Optical Coherence Tomography Angiography and its Relationship With the Visual Field in Eyes With Open-angle Glaucoma
    Igarashi, Ryoko
    Ochiai, Shun
    Togano, Tetsuya
    Sakaue, Yuta
    Suetake, Aki
    Iikawa, Ryu
    Honma, Yurie
    Miyamoto, Daiki
    Fukuchi, Takeo
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 492 - 497