Exploring the relationship between 24-2 visual field and widefield optical coherence tomography data across healthy, glaucoma suspect and glaucoma eyes

被引:1
|
作者
Tong, Janelle [1 ,2 ,3 ]
Phu, Jack [1 ,2 ,3 ,4 ,5 ]
Alonso-Caneiro, David [6 ,7 ]
Kugelman, Jason [7 ]
Khuu, Sieu [2 ]
Agar, Ashish [8 ]
Coroneo, Minas [8 ]
Kalloniatis, Michael [2 ,3 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Deakin Univ, Sch Med Optometry, Waurn Ponds, Vic 3216, Australia
[4] Univ Sydney, Fac Med, Sydney, NSW, Australia
[5] Concord Repatriat Gen Hosp, Concord Clin Sch, Sydney, NSW, Australia
[6] Univ Sunshine Coast, Sch Sci Technol & Engn, Sunshine Coast, Qld, Australia
[7] Queensland Univ Technol, Ctr Vis & Eye Res, Sch Optometry & Vis Sci, Kelvin Grove, Qld, Australia
[8] Univ New South Wales, Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
glaucoma; optical coherence tomography; visual fields; STANDARD AUTOMATED PERIMETRY; FIBER BUNDLE TRAJECTORIES; FULL THRESHOLD; SPATIAL SUMMATION; GANGLION-CELLS; OCULAR SHAPE; MODEL; SENSITIVITY; VARIABILITY; DEFECTS;
D O I
10.1111/opo.13368
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To utilise ganglion cell-inner plexiform layer (GCIPL) measurements acquired using widefield optical coherence tomography (OCT) scans spanning 55 degrees x 45 degrees to explore the link between co-localised structural parameters and clinical visual field (VF) data. Methods: Widefield OCT scans acquired from 311 healthy, 268 glaucoma suspect and 269 glaucoma eyes were segmented to generate GCIPL thickness measurements. Estimated ganglion cell (GC) counts, calculated from GCIPL measurements, were plotted against 24-2 SITA Faster visual field (VF) thresholds, and regression models were computed with data categorised by diagnosis and VF status. Classification of locations as VF defective or non-defective using GCIPL parameters computed across eccentricity- and hemifield-dependent clusters was assessed by analysing areas under receiver operating characteristic curves (AUROCCs). Sensitivities and specificities were calculated per diagnostic category. Results: Segmented linear regression models between GC counts and VF thresholds demonstrated higher variability in VF defective locations relative to non-defective locations (mean absolute error 6.10-9.93 dB and 1.43-1.91 dB, respectively). AUROCCs from cluster-wide GCIPL parameters were similar across methods centrally (p = 0.06-0.84) but significantly greater peripherally, especially when considering classification of more central locations (p < 0.0001). Across diagnoses, cluster-wide GCIPL parameters demonstrated variable sensitivities and specificities (0.36-0.93 and 0.65-0.98, respectively), with the highest specificities observed across healthy eyes (0.73-0.98). Conclusions: Quantitative prediction of VF thresholds from widefield OCT is affected by high variability at VF defective locations. Prediction of VF status based on cluster-wide GCIPL parameters from widefield OCT could become useful to aid clinical decision-making in appropriately targeting VF assessments.
引用
收藏
页码:1484 / 1499
页数:16
相关论文
共 50 条
  • [1] Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes
    Belbase, Umesh
    Maharjan, Indra Man
    Subedi, Anup
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2024, 36 (01): : 31 - 36
  • [2] Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes
    Yarmohammadi, Adeleh
    Zangwill, Linda M.
    Diniz-Filho, Alberto
    Suh, Min Hee
    Manalastas, Patricia Isabel
    Fatehee, Naeem
    Yousefi, Siamak
    Belghith, Akram
    Saunders, Luke J.
    Medeiros, Felipe A.
    Huang, David
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT451 - OCT459
  • [3] Application of optical coherence tomography in glaucoma suspect eyes
    Pomorska, Maria
    Krzyzanowska-Berkowska, Patrycja
    Misiuk-Hojlo, Marta
    Zajac-Pytrus, Hanna
    Grzybowski, Andrzej
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (01) : 78 - 88
  • [4] Optical Coherence Tomography Analysis Based Prediction of Humphrey 24-2 Visual Field Thresholds in Patients With Glaucoma
    Guo, Zhihui
    Kwon, Young H.
    Lee, Kyungmoo
    Wang, Kai
    Wahle, Andreas
    Alward, Wallace L. M.
    Fingert, John H.
    Bettis, Daniel I.
    Johnson, Chris A.
    Garvin, Mona K.
    Sonka, Milan
    Abramoff, Michael D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (10) : 3975 - 3985
  • [5] Optical Coherence Tomography analysis based prediction of Humphrey 24-2 visual field thresholds in patients with glaucoma
    Guo, Zhihui
    Kwon, Young H.
    Lee, Kyungmoo
    Wang, Kai
    Johnson, Chris A.
    Garvin, Mona K.
    Sonka, Milan
    Abramoff, Michael David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Glaucoma Specialist Detection of Optical Coherence Tomography Suspicious Rim Tissue in Glaucoma and Glaucoma Suspect Eyes
    Hong, Seung Woo
    Koenigsman, Helen
    Yang, Hongli
    Ren, Ruojin
    Reynaud, Juan
    Kinast, Robert M.
    Mansberger, Steven L.
    Fortune, Brad
    Demirel, Shaban
    Gardiner, Stuart K.
    Burgoyne, Claude F.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 199 : 28 - 43
  • [7] The Association Between Macula and ONH Optical Coherence Tomography Angiography (OCT-A) Vessel Densities in Glaucoma, Glaucoma Suspect, and Healthy Eyes
    Manalastas, Patricia I. C.
    Zangwill, Linda M.
    Daga, Fabio B.
    Christopher, Mark A.
    Saunders, Luke J.
    Shoji, Takuhei
    Akagi, Tadamichi
    Penteado, Rafaella C.
    Yarmohammadi, Adeleh
    Suh, Min H.
    Medeiros, Felipe A.
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2018, 27 (03) : 227 - 232
  • [8] Inter-eye Asymmetry of Optical Coherence Tomography Angiography Vessel Density in Bilateral Glaucoma, Glaucoma Suspect, and Healthy Eyes
    Hou, Huiyuan
    Moghimi, Sasan
    Zangwill, Linda M.
    Shoji, Takuhei
    Ghahari, Elham
    Manalastas, Patricia Isabel C.
    Penteado, Rafaella C.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 190 : 69 - 77
  • [9] Comparison between 24-2 and 10-2 visual fields and optical coherence tomography measurements in open-angle glaucoma
    Ancona, Chiara
    Ci, Paola Cira
    Telani, Serena
    Masala, Alessandro
    Traverso, Carlo Enrico
    Iester, Michele M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] Quantitative Optical Coherence Tomography Angiography of Radial Peripapillary Capillaries in Glaucoma, Glaucoma Suspect, and Normal Eyes
    Mammo, Zaid
    Heisler, Morgan
    Balaratnasingam, Chandrakumar
    Lee, Sieun
    Yu, Dao-Yi
    Mackenzie, Paul
    Schendel, Steven
    Merkur, Andrew
    Kirker, Andrew
    Albiani, David
    Navajas, Eduardo
    Beg, Mirza Faisal
    Morgan, William
    Sarunic, Marinko V.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 170 : 41 - 49