Impact of scattering phase function and polarization on the accuracy of diffuse and sub-diffuse spatial frequency domain imaging

被引:1
|
作者
Walter, Alec B. [1 ,2 ]
Jansen, E. Duco [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Biophoton Ctr, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Med Ctr, Dept Neurosurg, Nashville, TN 37235 USA
关键词
optical properties; scattering; spatial frequencies; backscattering; absorption; polarization; TURBID MEDIA;
D O I
10.1117/1.JBO.29.9.095001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance Although spatial frequency domain imaging (SFDI) has been well characterized under diffuse optical conditions, tissue measurements made outside the diffuse regime can provide new diagnostic information. Before such measurements can become clinically relevant, however, the behavior of sub-diffuse SFDI and its effect on the accuracy of derived tissue parameters must be assessed. Aim We aim to characterize the impact that both the assumed scattering phase function (SPF) and the polarization state of the illumination light source have on the accuracy of SFDI-derived optical properties when operating under diffuse or sub-diffuse conditions, respectively. Approach Through the use of a set of well-characterized optical phantoms, SFDI accuracy was assessed at four wavelengths (395, 545, 625, and 850 nm) and two different spatial frequencies (0.3 and 1.0 mm-1), which provided a broad range of diffuse and sub-diffuse conditions, using three different SPFs. To determine the effects of polarization, the SFDI accuracy was assessed using both unpolarized and cross-polarized illumination. Results It was found that the assumed SPF has a direct and significant impact on the accuracy of the SFDI-derived optical properties, with the best choice of SPF being dictated by the polarization state. As unpolarized SFDI retains the sub-diffuse portion of the signal, optical properties were found to be more accurate when using the full SPF that includes forward and backscattering components. By contrast, cross-polarized SFDI yielded accurate optical properties when using a forward-scattering SPF, matching the behavior of cross-polarization to attenuate the immediate backscattering of sub-diffuse reflectance. Using the correct pairings of SPF and polarization enabled using a reflectance standard, instead of a more subjective phantom, as the reference measurement. Conclusions These results provide the foundation for a more thorough understanding of SFDI and enable new applications of this technology in which sub-diffuse conditions dominate (e.g., mu a not less than mu s ') or high spatial frequencies are required.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging
    Yang, Bo
    Meng, Haoran
    Gu, Ning
    Liu, Xin
    Chen, Xiaofei
    Ben-Zion, Yehuda
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2024, 129 (05)
  • [22] Sources of errors in spatial frequency domain imaging of scattering media
    Bodenschatz, Nico
    Brandes, Arnd
    Liemert, Andre
    Kienle, Alwin
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
  • [23] Single-Fiber Diffuse Reflectance Spectroscopy and Spatial Frequency Domain Imaging in Surgery Guidance: A Study on Optical Phantoms
    Tseregorodtseva, Polina S.
    Buiankin, Kirill E.
    Yakimov, Boris P.
    Kamalov, Armais A.
    Budylin, Gleb S.
    Shirshin, Evgeny A.
    MATERIALS, 2021, 14 (24)
  • [24] Study of the Accuracy of Apple Internal Lesion Detection Based on Frequency Domain Diffuse Optical Tomography
    Li Jiang-tao
    Hu Wen-yan
    Zhao Long-lian
    Li Jun-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (09) : 2836 - 2841
  • [25] Profile-based diffuse reflectance corrections for improved optical property measurement of spherical fruit with spatial frequency domain imaging
    Yu, Shengqi
    Hu, Dong
    Qiu, Dekai
    Jia, Tianze
    Zhou, Tongtong
    Sun, Xiaolin
    Sun, Zhizhong
    Yan, Xiaojie
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2023, 204
  • [26] Wide-field illumination diffuse optical tomography within a framework of single-pixel time-domain spatial frequency domain imaging
    Bai, Wenxing
    Dong, Yihan
    Zhang, Yaru
    Wu, Ye
    Dan, Mai
    Liu, Dongyuan
    Gao, Feng
    OPTICS EXPRESS, 2024, 32 (04) : 6104 - 6120
  • [27] Modulation frequency improves imaging hemoglobin fluctuation in frequency domain high-density diffuse optical tomography
    Fan, Weihao
    Dehghani, Hamid
    Eggebrecht, Adam T.
    CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2022, 2022, 11945
  • [28] Next-generation frequency domain diffuse optical imaging systems using silicon photomultipliers
    Kitsmiller, Vincent J.
    O'Sullivan, Thomas D.
    OPTICS LETTERS, 2019, 44 (03) : 562 - 565
  • [29] Frequency-domain diffuse optical tomography of breast tissue: detector size and imaging geometry
    Pogue, BW
    Jiang, HB
    Paulsen, KD
    Osterberg, UL
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2745 - 2749
  • [30] Stroke core revealed by tissue scattering using spatial frequency domain imaging
    Sunil, Smrithi
    Erdener, Sefik Evren
    Cheng, Xiaojun
    Kura, Sreekanth
    Tang, Jianbo
    Jiang, John
    Karrobi, Kavon
    Kilic, Kivilcim
    Roblyer, Darren
    Boas, David A.
    NEUROIMAGE-CLINICAL, 2021, 29