Optimum delineation of skin structure for dose calculation with the linear Boltzmann transport equation algorithm in radiotherapy treatment planning

被引:0
|
作者
Hamada, Keisuke [1 ,2 ]
Fujibuchi, Toshioh [3 ]
Arakawa, Hiroyuki [3 ]
机构
[1] Natl Hosp Org Kagoshima Med Ctr, Dept Radiol Technol, 8-1 Shiroyama Cho, Kagoshima 8920853, Japan
[2] Kyushu Univ, Grad Sch Med, Dept Hlth Sci, Fukuoka, Japan
[3] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Fukuoka, Japan
关键词
Skin-surface dose; Skin-ring structure; Volumetric modulated arc therapy; Acuros XB; Head and neck; MODULATED RADIATION-THERAPY; FILM DOSIMETRY; HELICAL TOMOTHERAPY; RADIOCHROMIC FILM; NECK CANCERS; ARC THERAPY; HEAD; SURFACE; PRECISION; ACCURACY;
D O I
10.1007/s12194-024-00840-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigated the effectiveness of placing skin-ring structures to enhance the precision of skin dose calculations in patients who had undergone head and neck volumetric modulated arc therapy using the Acuros XB algorithm. The skin-ring structures in question were positioned 2 mm below the skin surface (skin A) and 1 mm above and below the skin surface (skin B) within the treatment-planning system. These structures were then tested on both acrylic cylindrical and anthropomorphic phantoms and compared with the Gafchromic EBT3 film (EBT3). The results revealed that the maximum dose differences between skins A and B for the cylindrical and anthropomorphic phantoms were approximately 12% and 2%, respectively. In patients 1 and 2, the dose differences between skins A and B were 9.2% and 8.2%, respectively. Ultimately, demonstrated that the skin-dose calculation accuracy of skin B was within 2% and did not impact the deep organs.
引用
收藏
页码:938 / 946
页数:9
相关论文
共 50 条
  • [21] The Impact of Dose Calculation Algorithm for SBRT Lung Cancer Radiotherapy Treatment
    Mostafa A.A.
    Hussein A.E.-A.E.
    Galal M.M.
    El-Shahat K.M.
    Iranian Journal of Medical Physics, 2022, 19 (05) : 290 - 295
  • [22] Dose calculation and reporting with a linear Boltzman transport equation solver in vertebral SABR
    Hardcastle, Nicholas
    Hughes, Jeremy
    Siva, Shankar
    Kron, Tomas
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (01) : 43 - 48
  • [23] Dose calculation and reporting with a linear Boltzman transport equation solver in vertebral SABR
    Nicholas Hardcastle
    Jeremy Hughes
    Shankar Siva
    Tomas Kron
    Physical and Engineering Sciences in Medicine, 2022, 45 : 43 - 48
  • [24] Comparison of selected dose calculation algorithms in radiotherapy treatment planning for tissues with inhomogeneities
    Woon, Y. L.
    Heng, S. P.
    Wong, J. H. D.
    Ung, N. M.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [25] Monte Carlo Evaluation of Superposition-Algorithm Skin Dose Calculation for Brain Radiotherapy
    Li, J.
    Xiao, Y.
    Yu, Y.
    Shi, V.
    MEDICAL PHYSICS, 2011, 38 (06) : 3653 - +
  • [26] Dosimetric impact of a model-based dose calculation algorithm in skin interventional radiotherapy
    Placidi, Elisa
    Fionda, Bruno
    Rosa, Enrico
    Lancellotta, Valentina
    Napolitano, Antonio
    De Angeli, Martina
    Pastore, Francesco
    Gambacorta, Maria Antonietta
    Indovina, Luca
    Tagliaferri, Luca
    De Spirito, Marco
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S378 - S380
  • [27] Experimental Validation of a Linear Boltzmann Transport Equation Solver for Rapid CT Dose Map Generation
    Principi, S.
    Liu, Y.
    Lu, Y.
    Ragan, D. K.
    Wang, A.
    Maslowski, A.
    Wareing, T.
    Schmidt, T. G.
    MEDICAL PHYSICS, 2020, 47 (06) : E263 - E263
  • [28] Commercial IMRT treatment-planning dose-calculation algorithm
    Low, DA
    Mutic, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04): : 933 - 937
  • [29] Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning
    Chamberland, Eve
    Beaulieu, Luc
    Lachance, Bernard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 60 - 79
  • [30] Photon dose calculation analysis of a varian treatment planning system algorithm on a siemens linear accelerator in inhomogeneous media
    Finlay, J.
    Mesina, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2481 - 2481