Performance analysis of double-stage heat pump and refrigeration cycles

被引:1
|
作者
Morisaki, Takafumi [1 ]
Ohara, Junichi [2 ]
Yasunaga, Takeshi [1 ]
Ikegami, Yasuyuki [1 ]
机构
[1] Saga Univ, Inst Ocean Energy, 1-48 Hirao,Yamashiro Cho, Imari, Saga, Japan
[2] Natl Fisheries Univ, 2-7-1 Nagata Honmachi, Shimonoseki, Yamaguchi, Japan
关键词
Double -stage cycle; Heat pump; Multistage cycle; Refrigeration cycle; RANKINE-CYCLE; ENERGY; POWER; EXERGY; SYSTEM; MIXTURES; WORKING; R513A;
D O I
10.1016/j.applthermaleng.2024.123732
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multistage refrigeration systems are investigated to/enhance the performance of vapor compression refrigeration cycles based on our previous work on multistage low-grade thermal energy conversion. A double-stage heat pump and refrigeration cycles (D-S) is expected to reduce the irreversible loss in the heat exchange process. However, certain characteristics of independently configured systems, namely, compressor power and coefficients of performance (COPs), have not been sufficiently clarified. This study aims to elucidate highly advanced heat pump and refrigeration systems by comparing D-S, a basic single-stage heat pump and refrigeration cycles, and a two-stage compression cycle. D-S shows higher COPs for both the refrigeration and heat pump cycles compared with the other cycles, especially at high thermal conductances. The reduction of the irreversible loss in the heat exchange process is confirmed via the entropy generation rate; in particular, the COP increases with a decrease in the entropy generation rate. The evaporation and condensation temperatures of the refrigerant approach the temperature of the heat source when the thermal conductance exceeds 150 kW/K for the refrigeration cycle. The heat exchangers exergy destruction of D-S is 169 kW, S-S is 189 kW, the two-stage cycle is 184 kW/K when the thermal conductance is 100 kW/K.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Adsorption behaviors and analysis of refrigeration/heat pump performance for zeolite-water
    Zhu, Ruiqi
    Han, Baoqi
    Ouyang, Yide
    Lin, Meizhen
    Journal of Xi'an Jiaotong University, 1991, 25 (04) : 9 - 16
  • [32] A NEW DOUBLE-STAGE CENTRIFUGAL
    TROJAN, G
    ZUCKERINDUSTRIE, 1993, 118 (06): : 456 - 457
  • [33] Sewage Anti-blocking Machine Principle and Double-stage Pump Technology
    Zhang, Chenghu
    Meng, Na
    Sun, Dexing
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 751 - 755
  • [34] DOUBLE-STAGE SHRUNKEN ESTIMATORS
    ALBAYYAT.H
    ARNOLD, JC
    BIOMETRICS, 1970, 26 (03) : 598 - &
  • [35] Entransy analysis on optimization of a double-stage latent heat storage unit with the consideration of an unequal separation
    Wang, C.
    Zhu, Y.
    ENERGY, 2018, 148 : 386 - 396
  • [36] Performance analysis for endoreversible closed regenerated Brayton heat pump cycles
    Ni, N
    Chen, LG
    Wu, C
    Sun, FR
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (04) : 393 - 406
  • [38] On the performance of irreversible combined heat pump cycles
    Chen, JC
    Yan, ZJ
    Chen, LX
    Andresen, B
    OCOS 2000: FROM THERMO-ECONOMICS TO SUSTAINABILITY, PTS 1-4, 2000, : 269 - 277
  • [39] Performance Analysis of Brine Chiller Refrigeration Cycles
    Yoon, Jung-In
    Son, Chang-Hyo
    Choi, Kwang-Hwan
    Kim, Young-Bok
    Jung, Suk-Ho
    Moon, Changuk
    AETA 2016: RECENT ADVANCES IN ELECTRICAL ENGINEERING AND RELATED SCIENCES: THEORY AND APPLICATION, 2017, 415 : 184 - 194
  • [40] Simulation of Double-Stage Absorption Heat Pumps for Low Grade Waste Heat Recovery
    Yang Xiaojing
    You Shijun
    Zhang Huan
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,