Development of ceramic layer on magnesium and its alloys for bone implant applications using plasma electrolytic oxidation (PEO)

被引:1
|
作者
Asad, Rabiya [1 ]
Uzair, S. Ahmed [2 ,3 ]
Mirza, Eraj Humayun [1 ]
Rizwan, M. [4 ]
Alias, Rodianah [5 ,6 ]
Chandio, Ali Dad [4 ]
Hussain, Fayaz [2 ]
机构
[1] NED Univ Engn & Technol, Dept Biomed Engn, Karachi 75270, Pakistan
[2] NED Univ Engn & Technol, Dept Mat Engn, Karachi 75270, Pakistan
[3] Karachi Inst Power Engn KINPOE, Coll Pakistan Inst Engn & Appl Sci PIEAS, Nilore, Pakistan
[4] NED Univ Engn & Technol, Dept Met Engn, Karachi 75270, Pakistan
[5] Univ Sultan Zainal Abidin, Fac Innovat Design & Technol, Campus Gong Badak, Kuala Nerus 21300, Terengganu Daru, Malaysia
[6] Univ Sultan Zainal Abidin, Fac Innovat Design & Technol, Biomat & Nanomat Res Grp, Smart Technol Cluster, Campus Gong Badak, Kuala Nerus 21300, Terengganu Daru, Malaysia
关键词
Plasma Electrolytic Oxidation (PEO); Bone implant; Biocompatibility; Bioactivity; Magnesium; VITRO CORROSION-RESISTANCE; BIOACTIVE GLASS COATINGS; MICRO-ARC OXIDATION; MG ALLOY; ORTHOPEDIC BIOMATERIALS; ELECTRICAL PARAMETERS; AZ31; BEHAVIOR; BIOCOMPATIBILITY; MICROSTRUCTURE;
D O I
10.1007/s41779-024-01045-3
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The use of magnesium (Mg) and its alloys as potential materials for bone implants is gaining attention of researchers. This is due to their biocompatibility, mechanical properties, and ability to degrade in the body. Plasma Electrolytic Oxidation (PEO) is a promising surface modification technique for enhancing the performance of magnesium and its alloys in orthopedic and dental implants. It helps develop an oxide ceramic layer on the surface. This article provides an in-depth analysis of the recent advancements in PEO of magnesium and related alloys for use in bone implants. It begins by explaining the fundamental principles of PEO, including the electrochemical and plasma processes involved in forming ceramic coatings on magnesium substrates. It then describes how various factors affect the oxide layers. These include the electrolyte mixture, voltage, current density, and treatment length. It focuses on the microstructure, biocompatibility, and corrosion resistance of PEO-treated magnesium alloys. Additionally, it explains the biocompatibility and bioactivity performance of the PEO-coated magnesium alloys. This involves their interactions with biological systems, cell adhesion, proliferation, and osseointegration. The review also covers challenges and limitations of PEO. Its comprehensive analysis of PEO technique, surface characteristics, mechanical properties, corrosion behavior, and biocompatibility aspects is valuable. It's a resource for researchers, clinicians, and materials scientists creating novel, biocompatible magnesium-based materials. These materials are suitable for dental and orthopedic implants. As the field continues to evolve, further research directions and potential breakthroughs are outlined to propel the application of PEO-treated magnesium alloys in the realm of bone implants, offering patients improved medical outcomes and enhanced quality of life.
引用
收藏
页码:1361 / 1380
页数:20
相关论文
共 50 条
  • [41] Research Progress on the Wear and Corrosion Resistant Plasma Electrolytic Oxidation Composite Coatings on Magnesium and Its Alloys
    Zhao, Chen
    Wang, Xingwei
    Yu, Bo
    Cai, Meirong
    Yu, Qiangliang
    Zhou, Feng
    COATINGS, 2023, 13 (07)
  • [42] The influence of metallurgical state of substrate on the efficiency of plasma electrolytic oxidation (PEO) process on magnesium alloy
    Martin, J.
    Nomine, A. V.
    Stef, J.
    Nomine, A.
    Zou, J. X.
    Henrion, G.
    Grosdidier, T.
    MATERIALS & DESIGN, 2019, 178
  • [43] Anticorrosive lanthanum embedded PEO/GPTMS coating on magnesium alloy by plasma electrolytic oxidation with silanization
    Telmenbayar, Lkhagvaa
    Ramu, Adam Gopal
    Erdenebat, Tumur-Ochir
    Choi, Dongjin
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [44] A comprehensive review of plasma electrolytic oxidation (PEO) of tantalum (Ta): Mechanisms, properties, and applications
    Fattah-alhosseini, Arash
    Chaharmahali, Razieh
    Dikici, Burak
    Kaseem, Mosab
    INTERNATIONAL JOURNAL OF REFRACTORY METALS & HARD MATERIALS, 2025, 128
  • [45] Thermal Conductivities of Nanostructured Magnesium Oxide Coatings Deposited on Magnesium Alloys by Plasma Electrolytic Oxidation
    Shen, Xinwei
    Nie, Xueyuan
    Hu, Henry
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (10) : 7933 - 7937
  • [46] Phase formation in ceramic coatings during plasma electrolytic oxidation of aluminium alloys
    Yerokhin, AL
    Lyubimov, VV
    Ashitkov, RV
    CERAMICS INTERNATIONAL, 1998, 24 (01) : 1 - 6
  • [47] Preparation of a novel yellow ceramic coating on Ti alloys by plasma electrolytic oxidation
    Jiang, Yanli
    Wang, Jiankang
    Hu, Bing
    Yao, Zhongping
    Xia, Qixing
    Jiang, Zhaohua
    SURFACE & COATINGS TECHNOLOGY, 2016, 307 : 1297 - 1302
  • [48] Doping and defects: The coloring mechanism of black plasma electrolytic oxidation (PEO) films on aluminum alloys
    Pan, Jinlong
    Wen, Yanwei
    Wang, Lili
    Wu, Zhiyong
    Dong, Hui
    Ye, Zuoyan
    SURFACE & COATINGS TECHNOLOGY, 2022, 431
  • [49] Modification of titanium alloys surface properties by plasma electrolytic oxidation (PEO) and influence on biological response
    Mónica Echeverry-Rendón
    Oscar Galvis
    Robinson Aguirre
    Sara Robledo
    Juan Guillermo Castaño
    Félix Echeverría
    Journal of Materials Science: Materials in Medicine, 2017, 28
  • [50] Modification of titanium alloys surface properties by plasma electrolytic oxidation (PEO) and influence on biological response
    Echeverry-Rendon, Monica
    Galvis, Oscar
    Aguirre, Robinson
    Robledo, Sara
    Guillermo Castano, Juan
    Echeverria, Felix
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2017, 28 (11)