PID Control for Building with an Active Mass Damper

被引:0
|
作者
Saidi, Abdelkrim [1 ]
Zizouni, Khaled [1 ]
Fali, Leyla [2 ]
Bousserhane, Ismail Khalil [1 ]
机构
[1] TAHRI Mohamed Univ Bechar, ArchiPEL Lab, Bechar, Algeria
[2] TAHRI Mohamed Univ Bechar, FIMAS Lab, Bechar, Algeria
关键词
Structural control; Vibration suppress; PID controller; Aseismic systems; Active mass;
D O I
10.1007/978-981-99-5922-8_25
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the civil engineering area, structural control technology takes real consideration, especially in recent works and research. However, the active mass damper is a control device used in several cases to suppress undesired structural vibrations caused by winds or earthquakes. Thus, the active device offers the real-time adjustment possibility of structural responses. This paper proposes an active mass damper to mitigate structural vibration caused by ground acceleration. The tested structure is a three-scaled structure excited using the 2003 Boumerdes earthquake excitation. To calculate the desired force of control, a proportional integral derivative algorithm is proposed in a closed loop. The active control is evaluated via numerical simulation results of compared displacement responses of the uncontrolled structure to those of the active-controlled structure. The carried-out results proved the active control strategy's effectiveness in suppressing the excited structures' vibration.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 50 条
  • [1] Adaptive Vibration Control for an Active Mass Damper of a High-Rise Building
    Feng, Jiali
    Liu, Zhijie
    He, Xiuyu
    Fu, Qiang
    Li, Guang
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2022, 52 (03): : 1970 - 1983
  • [2] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Shin, Ji-Hwan
    Kwak, Moon K.
    Kim, Soo-Min
    Baek, Kwang-Hyun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 5005 - 5015
  • [3] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Ji-Hwan Shin
    Moon K. Kwak
    Soo-Min Kim
    Kwang-Hyun Baek
    Journal of Mechanical Science and Technology, 2020, 34 : 5005 - 5015
  • [4] Seismic adaptive control of building structures using active friction tuned mass damper
    Saadatfar, Saman
    Emami, Fereshteh
    Khatibinia, Mohsen
    Eliasi, Hussein
    STRUCTURES, 2024, 70
  • [5] Joint Optimization Approach to Building Vibration Control via Active Tuned Mass Damper
    Zhan, Wei
    Cui, Yukang
    Feng, Zhiguang
    Lam, James
    Gao, Huijun
    DYNAMICS FOR SUSTAINABLE ENGINEERING, VOL 1, 2011, : 482 - 491
  • [6] Adaptive control for an active mass damper of a high-rise building with input backlash
    Zhao, Zhijia
    Chen, Yihang
    Zou, Tao
    Teng, Xiaofei
    Ma, Yuhong
    CONTROL ENGINEERING PRACTICE, 2024, 150
  • [7] Active Control for a Distributed Mass Damper System
    Fu, Tat S.
    Johnson, Erik A.
    JOURNAL OF ENGINEERING MECHANICS, 2014, 140 (02) : 426 - 429
  • [8] Fuzzy neural network control algorithm for asymmetric building structure with active tuned mass damper
    Yan, Xiao
    Xu, Zhao-Dong
    Shi, Qing-Xuan
    JOURNAL OF VIBRATION AND CONTROL, 2020, 26 (21-22) : 2037 - 2049
  • [9] Analytical and experimental studies on building mass damper system with semi-active control device
    Liu, Yu-Fang
    Lin, Tzu-Kang
    Chang, Kuo-Chun
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (06):
  • [10] Vibration Control for an Active Mass Damper of a High-Rise Building With Input and Output Constraints
    Zhang, Shuang
    Li, Qian
    Zhao, Xuena
    Liu, Zhijie
    Li, Guang
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2023, 28 (01) : 186 - 196