Vibration Control for an Active Mass Damper of a High-Rise Building With Input and Output Constraints

被引:11
|
作者
Zhang, Shuang [1 ,2 ]
Li, Qian [1 ,2 ]
Zhao, Xuena [1 ,2 ]
Liu, Zhijie [1 ,2 ]
Li, Guang [3 ]
机构
[1] Univ Sci & Technol Beijing, Sch Intelligence Sci & Technol, Beijing 100083, Peoples R China
[2] Univ Sci & Technol Beijing, Inst Artificial Intelligence, Beijing 100083, Peoples R China
[3] Queen Mary Univ London, Sch Engn & Mat Sci, London E1 4NS, England
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Buildings; Vibrations; Force; Mathematical models; Shock absorbers; Vibration control; Lyapunov methods; Active mass damper (AMD); high-rise buildings; input constraints; output constraints; vibration control; NONLINEAR-SYSTEMS; TRACKING CONTROL; BOUNDARY CONTROL; STABILIZATION; DISTURBANCE;
D O I
10.1109/TMECH.2022.3201261
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Aiming at the windproof and seismic problems of a high-rise building with large flexible structures, this article introduces a boundary control technology for a high-rise building with active mass damper (AMD) under input and output constraints. Hamilton's principle is used to establish an infinite-dimensional distributed parameter system model of a high-rise building with AMD. Based on the partial differential equations model, a boundary control law with input and output constraints is proposed, where the bounded input constraints are handled by a smooth hyperbolic tangent function and the output constraints are dealt with by a barrier Lyapunov function. It is proved that the vibration is well suppressed by the controller, and the input and output constraints are not violated. Numerical simulations and experiments are used to verify the effectiveness of the control performance.
引用
收藏
页码:186 / 196
页数:11
相关论文
共 50 条
  • [1] Adaptive Vibration Control for an Active Mass Damper of a High-Rise Building
    Feng, Jiali
    Liu, Zhijie
    He, Xiuyu
    Fu, Qiang
    Li, Guang
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2022, 52 (03): : 1970 - 1983
  • [2] Adaptive control for an active mass damper of a high-rise building with input backlash
    Zhao, Zhijia
    Chen, Yihang
    Zou, Tao
    Teng, Xiaofei
    Ma, Yuhong
    CONTROL ENGINEERING PRACTICE, 2024, 150
  • [3] Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper
    Aly, Aly Mousaad
    SMART STRUCTURES AND SYSTEMS, 2014, 13 (03) : 473 - 500
  • [4] Torsional Vibration Control of High-rise Building with Large Local Space by Using Tuned Mass Damper
    Zhao, Bin
    Gao, Hui
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 3066 - +
  • [5] Numerical and experimental investigation of control performance of active mass damper system to high-rise building in use
    Park, S. J.
    Lee, J.
    Jung, H. J.
    Jang, D. D.
    Kim, S. D.
    WIND AND STRUCTURES, 2009, 12 (04) : 313 - 332
  • [6] Numerical and experimental investigation of control performance of active mass damper system to high-rise building in use
    R and D Technique Institute, Lotte Engineering and Construction Co. Ltd., Seoul 140-1ll, Korea, Republic of
    不详
    不详
    Wind Struct Int J, 2009, 4 (313-332): : 313 - 332
  • [8] High-Rise Building Seismic Vibration Control Using Large Tuned Top-Floor Mass Damper
    Makino, Akifumi
    JOURNAL OF DISASTER RESEARCH, 2009, 4 (03) : 246 - 252
  • [9] Vibration mitigation performance of active tuned mass damper in a super high-rise building during multiple tropical storms
    Zhou, Kang
    Li, Qiu-Sheng
    ENGINEERING STRUCTURES, 2022, 269
  • [10] Analysis and design of active mass damper (AMD) control against wind and earthquake for a high-rise building in Dalian
    Ou, Jinping
    Zhang, Chunwei
    Li, Hui
    Peng, Junyi
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2004, 25 (03):