Correlating Evans Index, Callosal Angle, and Lateral Ventricle Volume With Gait Response Outcomes in Idiopathic Normal Pressure Hydrocephalus Diagnosis

被引:0
|
作者
Rohatgi, Saurabh [1 ]
Dua, Amol [1 ]
Diociasi, Andrea [1 ]
Buch, Karen [1 ]
Avesta, Arman [1 ]
Ford, Jeremy [1 ]
Gupta, Rajiv [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Div Neuroradiol, 55 Fruit St, Boston, MA 02114 USA
关键词
normal pressure hydrocephalous; callosal index (CI); Evans index (EI); ventricular volume; gait; SHUNT SURGERY; MRI;
D O I
10.1097/RCT.0000000000001602
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Radiological imaging is pivotal in diagnosing idiopathic normal pressure hydrocephalus (iNPH), given the similarity of its symptoms to other neurodegenerative diseases. We aimed to correlate the Evans index (EI), callosal angle (CA), and the volume of the lateral ventricles measured before cerebrospinal fluid removal with the resultant outcomes in gait response. MethodsIn our retrospective study, we identified 42 patients with a diagnosis of iNPH. These patients underwent gait analysis, imaging, and lumbar puncture. Radiological assessments included measurements of CA EI and lateral ventricular volume. Clinically, we assessed the following 4 gait parameters: cadence, gait speed, stride length, and timed up and go. Change in the 4 gait parameters was calculated, normalized, and compiled into a composite score, following which the group was divided into 'responders' and 'nonresponders' based on z score of 0.5. Our dependent variable was clinical improvement in gait, and our independent variables included lateral ventricular volume, EI, and CA. We performed a Wilcoxon rank-sum test to compare significant responder status using CA, EI, and lateral ventricle volume. A receiver operating characteristic analysis was employed to determine which volume measurement exhibited the strongest correlation with responder status. Determining the significant variables, a chi-square analysis was subsequently conducted. A significance threshold was set at P < 0.05. All our statistical evaluations were conducted in the Spyder environment, which is compatible with Python 3.10. Methods In our retrospective study, we identified 42 patients with a diagnosis of iNPH. These patients underwent gait analysis, imaging, and lumbar puncture. Radiological assessments included measurements of CA EI and lateral ventricular volume. Clinically, we assessed the following 4 gait parameters: cadence, gait speed, stride length, and timed up and go. Change in the 4 gait parameters was calculated, normalized, and compiled into a composite score, following which the group was divided into 'responders' and 'nonresponders' based on z score of 0.5. Our dependent variable was clinical improvement in gait, and our independent variables included lateral ventricular volume, EI, and CA. We performed a Wilcoxon rank-sum test to compare significant responder status using CA, EI, and lateral ventricle volume. A receiver operating characteristic analysis was employed to determine which volume measurement exhibited the strongest correlation with responder status. Determining the significant variables, a chi-square analysis was subsequently conducted. A significance threshold was set at P < 0.05. All our statistical evaluations were conducted in the Spyder environment, which is compatible with Python 3.10. Results There was a significant difference for responder status in EI and lateral ventricle volume. Evan index showing a statistic of 2.202 (P value = 0.02) and lateral ventricle volume demonstrating a statistic of 2.086 (P value = 0.03). Subsequent exploration using receiver operating characteristic analysis, with area under the curve of 0.71, identified 105.40 cm3 as the most robustly correlated volume threshold with responder status. Conclusions The lateral ventricular volume demonstrates a stronger correlation with gait improvement compared to the CA or EI. These observations indicate that evaluating the lateral ventricle volume before lumbar puncture could serve as a predictor for gait response after lumbar puncture in individuals with normal pressure hydrocephalus.
引用
收藏
页码:814 / 818
页数:5
相关论文
共 50 条
  • [31] Brain and Ventricle Volume Alterations in Idiopathic Normal Pressure Hydrocephalus Determined by Artificial Intelligence-Based MRI Volumetry
    Bendella, Zeynep
    Purrer, Veronika
    Haase, Robert
    Zuelow, Stefan
    Kindler, Christine
    Borger, Valerie
    Banat, Mohammed
    Dorn, Franziska
    Wuellner, Ullrich
    Radbruch, Alexander
    Schmeel, Frederic Carsten
    DIAGNOSTICS, 2024, 14 (13)
  • [32] The investigation of the gait parameter alterations in response to levodopa therapy and tap test in patients with idiopathic normal pressure hydrocephalus
    Onder, Halil
    Poyraz, Umur
    Comoglu, Selcuk
    NEUROLOGICAL SCIENCES, 2022, 43 (12) : 6813 - 6820
  • [33] The investigation of the gait parameter alterations in response to levodopa therapy and tap test in patients with idiopathic normal pressure hydrocephalus
    Halil Onder
    Umur Poyraz
    Selcuk Comoglu
    Neurological Sciences, 2022, 43 : 6813 - 6820
  • [34] Value of Quantitative MRI Biomarkers (Evans' Index, Aqueductal Flow Rate, and Apparent Diffusion Coefficient) in Idiopathic Normal Pressure Hydrocephalus
    Ng, Samuel E. S.
    Low, Angela M. S.
    Tang, Kok Kee
    Chan, Y. H.
    Kwok, Robert K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) : 708 - 715
  • [35] Use of cortical volume to predict response to temporary CSF drainage in patients with idiopathic normal pressure hydrocephalus
    Lang, Stefan
    Dimond, Dennis
    Isaacs, Albert M.
    Dronyk, Jarred
    Vetkas, Artur
    Conner, Christopher R.
    Germann, Jurgen
    Fasano, Alfonso
    Kalia, Suneil
    Lozano, Andres
    Hamilton, Mark G.
    JOURNAL OF NEUROSURGERY, 2023, 139 (06) : 1776 - 1783
  • [36] Diagnosis, treatment and analysis of long-term outcomes in idiopathic normal-pressure hydrocephalus - Comments
    Chandler, William F.
    McComb, J. Gordon
    Grossman, Robert G.
    NEUROSURGERY, 2008, 62 (02) : 676 - 676
  • [37] Diagnosis, treatment, and analysis of long-term outcomes in idiopathic normal-pressure hydrocephalus - Comments
    Chandler, WF
    McComb, JG
    Grossman, RG
    NEUROSURGERY, 2005, 57 (04) : 705 - 705
  • [38] Diffusion tensor imaging in elderly patients with idiopathic normal pressure hydrocephalus or Parkinson's disease: diagnosis of gait abnormalities
    Marumoto, Kohei
    Koyama, Tetsuo
    Hosomi, Masashi
    Kodama, Norihiko
    Miyake, Hiroji
    Domen, Kazuhisa
    FLUIDS AND BARRIERS OF THE CNS, 2012, 9
  • [39] Diffusion tensor imaging in elderly patients with idiopathic normal pressure hydrocephalus or Parkinson’s disease: diagnosis of gait abnormalities
    Kohei Marumoto
    Tetsuo Koyama
    Masashi Hosomi
    Norihiko Kodama
    Hiroji Miyake
    Kazuhisa Domen
    Fluids and Barriers of the CNS, 9 (1)
  • [40] Letter to the Editor Regarding "The Quest for Predicting Sustained Shunt Response in Normal-Pressure Hydrocephalus: An Analysis of the Callosal Angle's Utility"
    Sun, Tong
    Guan, Junwen
    WORLD NEUROSURGERY, 2018, 119 : 452 - 452