Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study

被引:1
|
作者
Guo, Houzuo [1 ]
Jiang, Xi [1 ]
Lin, Ye [1 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 22 Zhongguancun South St, Beijing 10081, Peoples R China
关键词
Zygomatic implant; Robotic system; Dynamic navigation system; Surgical accuracy; In vitro study; Maxillary atrophy rehabilitation; ACCURACY; MANAGEMENT; BONE; REHABILITATION; SURGERY; MAXILLA; ATROPHY;
D O I
10.1016/j.jdent.2024.105329
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of robotic and dynamic navigation systems in assisting zygomatic implant (ZI) using an in vitro model experiment. Methods: Preoperative cone-beam computed tomography (CBCT) images of patients who underwent ZI treatment between 2011 and 2023 were collected from local databases. Corresponding three-dimensional resin models were printed and assigned to two groups: the robotic and dynamic navigation system groups. Following preoperative plans, ZIs were placed in the models with the assistance of either a robotic or dynamic navigation system. Deviations in the in vitro navigation surgery were measured and compared between the groups. Results: A total of 110 ZIs were placed in 56 models, with 55 ZIs in each group. No significant differences were observed in entry and angle deviations between the groups (p>0.05). However, the exit deviation in the robotic system group (2.39+1.24 mm) was larger than that in the dynamic navigation group (1.83+1.25 mm) (p<0.05). On the exit side, the Z-axis deviation in the robotic group (left: -0.28+1.43 mm, right: -0.21+1.30 mm) was smaller than that in the dynamic navigation group (left: 0.76+1.11 mm, right: 0.85+1.52 mm) (p<0.05), while no significant differences were found in X- and Y-axis deviations (p>0.05). Conclusions: Compared with the dynamic navigation system, the robotic system can effectively prevent ZI overextension. However, its accuracy on the exit side is slightly lower than that of the dynamic navigation system. Clinical Significance: This preliminary in vitro study showed that the accuracy of the robotic system was slightly inferior to that of the dynamic navigation system in terms of exit deviation when used in ZI placement. Further clinical studies are required to confirm these findings.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Navigation System Approach in Zygomatic Implant Technique
    Gasparini, Giulio
    Boniello, Roberto
    Lafori, Andreina
    De Angelis, Paolo
    Del Deo, Vito
    Moro, Alessandro
    Saponaro, Gianmarco
    Pelo, Sandro
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (01) : 250 - 251
  • [22] Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Zhuang, Minjie
    Chen, Xiaojun
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF DENTISTRY, 2022, 123
  • [23] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [24] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Jianping Chen
    Xiaolei Bai
    Yude Ding
    Liheng Shen
    Xin Sun
    Ruijue Cao
    Fan Yang
    Linhong Wang
    BMC Oral Health, 23
  • [25] Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study
    Ma, Feifei
    Sun, Feng
    Wei, Tai
    Ma, Yu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (03) : 352 - 360
  • [26] Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
    Shen, Yihan
    Dai, Qinggang
    Tao, Baoxin
    Huang, Wei
    Wang, Feng
    Lan, Kengliang
    Sun, Yuanyuan
    Ling, Xiaowan
    Yan, Lijun
    Wang, Yueping
    Wu, Yiqun
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (176):
  • [27] Dynamic Navigation for Dental Implant Placement
    Pinter, Gabor Tamas
    Decker, Roland
    Szenasi, Gabor
    Barabas, Peter
    Huszar, Tamas
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (187):
  • [28] Influence of experience on dental implant placement: an in vitro comparison of freehand, static guided and dynamic navigation approaches
    Wang, Xiaotong
    Shaheen, Eman
    Shujaat, Sohaib
    Meeus, Jan
    Legrand, Paul
    Lahoud, Pierre
    do Nascimento Gerhardt, Mauricio
    Politis, Constantinus
    Jacobs, Reinhilde
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [29] Influence of experience on dental implant placement: an in vitro comparison of freehand, static guided and dynamic navigation approaches
    Xiaotong Wang
    Eman Shaheen
    Sohaib Shujaat
    Jan Meeus
    Paul Legrand
    Pierre Lahoud
    Maurício do Nascimento Gerhardt
    Constantinus Politis
    Reinhilde Jacobs
    International Journal of Implant Dentistry, 8
  • [30] Effect of a dynamic navigation device on the accuracy of implant placement in the completely edentulous mandible: An in vitro study
    Feng, Yuzhang
    Yao, Yufei
    Yang, Xingmei
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 731 - 737