Establishment of institutional Diagnostic Reference Levels for Computed Tomography examination at the University of Ghana Medical Centre

被引:0
|
作者
Issahaku, Shirazu [1 ,2 ]
Amoh, Simon Mensah [3 ]
Acquah, Isaac Kwesi [4 ]
Nunoo, George [3 ]
Sackey, Theophilus A. [1 ,2 ]
机构
[1] Ghana Atom Energy Commiss, Accra, Ghana
[2] Univ Ghana, Dept Med Phys, Legon, Accra, Ghana
[3] Univ Ghana, Med Ctr, Dept Radiol, Accra, Ghana
[4] Univ Educ, Dept Phys Educ, Winneba, Ghana
关键词
Diagnostic reference levels; Computed tomography dose index; Computed tomography; Radiation exposure; Dose-length product; Radiation protection; CT EXAMINATIONS; ADULT; OPTIMIZATION; CHEST; HEAD;
D O I
10.1007/s12553-024-00902-2
中图分类号
R-058 [];
学科分类号
摘要
IntroductionDiagnostic Reference Levels are important indicators for monitoring and optimizing protocol and procedure in medical imaging between facilities and equipment. This helps to evaluate whether, in routine clinical conditions, the median value obtained for a representative group of patients are within an agreed range from a specified procedure is unusually high or low for that procedure. This study aimed to propose Diagnostic Reference Levels for Computed Tomography examination of the most common routine examination of the head, chest and abdominal pelvis regions at the University of Ghana Medical Centre.MethodsThe Diagnostic Reference Levels were determined based on the investigation of the most common routine examinations including head Computed Tomography examination with and without contrast, abdominopelvic Computed Tomography examination with and without contrast, and chest Computed Tomography examination without contrast. The study was based on two dose indicators; the volumetric Computed Tomography Dose Index and Dose-Length Product.ResultsThe estimated median distribution for head Computed Tomography with contrast for volumetric-Computed Tomography dose index and Dose-Length Product were 38.33 mGy and 829.35 mGy.cm, while without contrast, were 38.90 mGy and 860.90 mGy.cm respectively. For an abdominopelvic Computed Tomography examination with contrast, the estimated volumetric-Computed Tomography dose index and Dose-Length Product values were 40.19 mGy and 2096.60 mGy.cm. While without contrast, the estimated values were 14.65 mGy and 800.40 mGy.cm respectively. Additionally, for chest Computed Tomography examination, the estimated values were: 12.75 mGy and 423.95 mGy.cm for volumetric-Computed Tomography dose index and Dose-Length Product respectively. These median values represent the proposed diagnostic reference values of the head, chest and abdominal pelvis regions.ConclusionsThe proposed Diagnostic Reference Level are comparable to recommended International Atomic Energy Agency and International Commission Radiation Protection Publication 135 and other regional published data by European Commission and Regional National Diagnostic Reference Level in Africa. These reference levels will serve as benchmarks to guide clinicians in optimizing radiation dose levels while ensuring accurate diagnostic image quality at the facility.
引用
收藏
页码:1199 / 1207
页数:9
相关论文
共 50 条
  • [31] The establishment of local diagnostic reference levels for computed tomography cerebral angiography in Jeddah city of Saudi Arabia
    Khan, Khadijah
    Al-Harbi, Afnan
    Fallatah, Alaa
    Alasmary, Mohamed
    Bokhary, Younis
    Alhazmi, Marwan
    Al-Qahtani, Saeed
    Ajlouni, Abdulwali
    Alotaibi, Emtenan
    Alomari, Ali
    Althomali, Marwan
    Algethami, Merfat
    Bawazeer, Omemh
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2025, 56 (01):
  • [32] Establishment of Regional Diagnostic Reference Levels in Adult Computed Tomography for Four African Countries: A Preliminary Survey
    Uushona, Vera
    Boadu, Mary
    Nyabanda, Rose
    Diagne, Magatte
    Inkoom, Stephen
    Issahaku, Shiraz
    Hasford, Francis
    Haiduwa, Paulus
    Koteng, Arthur
    Omondi, Bob
    Diop, Adji Yaram
    Gilley, Debbie Bray
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 414 - 422
  • [33] Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 983 - 991
  • [34] Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging
    Steuwe A.
    Thomas C.
    Kraus B.
    Bethge O.T.
    Aissa J.
    Klosterkemper Y.
    Antoch G.
    Boos J.
    Journal of Radiological Protection, 2020, 40 (01) : 68 - 82
  • [35] The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital
    Amalia, T.
    Zulkarnaien, B.
    Anam, C.
    Nurcahyo, K.
    Tussyadiah, H.
    Pradana, D. E.
    ATOM INDONESIA, 2022, 48 (02) : 159 - 167
  • [36] Establishment of an institutional diagnostic reference level for vascular lower extremity computed tomography angiography (vol 217, 111460, 2024)
    Sulieman, Abdelmoneim
    Alkhorayef, Mohammed
    Alkhaybari, Essam
    Jaafar, Rasha
    Elnour, Abdelrahman
    Almujally, Abdullah
    Babikir, Esameldeen
    Abuzaid, Mohamed
    Abuhadi, Nouf
    Salah, Hassan
    Bradley, David A.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [37] Establishment of reference levels of computed tomography doses in a health group in Singapore
    Gabalda-Martinez, Lluis
    Garcia-Gorga, Rodrigo
    IMAGEN DIAGNOSTICA, 2023, 14 (01): : 9 - 15
  • [38] Australian diagnostic reference levels for multi detector computed tomography
    Anna Hayton
    Anthony Wallace
    Paul Marks
    Keith Edmonds
    David Tingey
    Peter Johnston
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 19 - 26
  • [39] Canadian Computed Tomography Survey: National Diagnostic Reference Levels
    Wardlaw, Graeme M.
    Martel, Narine
    MEDICAL PHYSICS, 2016, 43 (08) : 4932 - 4933
  • [40] Australian diagnostic reference levels for multi detector computed tomography
    Hayton, Anna
    Wallace, Anthony
    Marks, Paul
    Edmonds, Keith
    Tingey, David
    Johnston, Peter
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (01) : 19 - 26