Primary Frequency Reserve Providing Strategy of Doubly-Fed Induction Generator Wind Generation Using Rotor Inertia Characteristics

被引:0
|
作者
Hwang, Min [1 ,2 ]
Kook, Kyung-Soo [2 ]
机构
[1] Korea Elect Safety Corp, Elect Safety Res Inst, Wonju 55365, South Korea
[2] Jeonbuk Natl Univ, Dept Elect Engn, Jeonju 54896, South Korea
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Wind speed; Frequency control; Rotors; Power grids; Voltage control; Reliability; Wind energy; Wind power generation; primary frequency reserve; de-loaded control; doubly-fed induction generator; wind power; ENERGY; SYSTEM; SUPPORT; SPEED;
D O I
10.1109/ACCESS.2024.3432829
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For power grids with a high penetration level of wind power generation, stochastic wind speed variation adversely affects the frequency stability. A variable-speed wind turbine generator would deloads its output by shifting the power operating point to provide frequency response. Because the wind speed variation directly affects the calculation of the operating point, difficulties arise in securing a reliable amount of the frequency response. This paper proposes a control scheme of a doubly fed induction generator (DFIG)-based wind generation providing the primary frequency reserve (PFR), which can improve its reliability and flexibility even with a continuously varying wind speed. To achieve these objectives, the proposed scheme employs a de-loaded operation control loop associated with the rotational inertia characteristics of the DFIG. In addition, a static gain-based droop control loop is employed to release the required amount of active power from the system operator. In the proposed scheme, the optimal operating point for de-loaded operation varies more smoothly than it does in a conventional scheme by using the rotor inertia characteristics. The performance of the proposed control scheme is demonstrated using an EMTP-RV simulator under various wind speeds. The simulation results indicate that the proposed scheme significantly improves the frequency support capability of the DFIG in both the process of securing and providing the PFR.
引用
收藏
页码:124128 / 124140
页数:13
相关论文
共 50 条
  • [21] A frequency control scheme of a doubly-fed induction generator considering random wind speeds
    Zhao, Teyang
    Liu, Hui
    Luo, Zhiqiang
    Su, Yi
    Huang, Lidong
    Li, Huijie
    Sun, Zhiyuan
    ENERGY REPORTS, 2023, 9 : 235 - 244
  • [22] Wind Turbine using Doubly-Fed Induction Generator Protection during Fault
    Ibrahima, Kone
    Zhao, Chengyong
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON INFORMATION, BUSINESS AND EDUCATION TECHNOLOGY (ICIBET 2013), 2013, 26 : 1330 - 1336
  • [23] Wind power system using doubly-fed induction generator and matrix converter
    Lee, Dong-Geun
    Kwon, Gi-Hyun
    Han, Byung-Moon
    Li, Yu-Long
    Choi, Nam-Sup
    Choy, Young-Do
    Transactions of the Korean Institute of Electrical Engineers, 2008, 57 (06): : 985 - 993
  • [24] The Control Strategy of The Rotor-Side PWM Converter Based on Doubly-Fed Induction Generator
    Zhao, Meihua
    Fan, Min
    Wu, Xiaoxin
    AUTOMATIC MANUFACTURING SYSTEMS II, PTS 1 AND 2, 2012, 542-543 : 204 - +
  • [25] Decoupling Control Strategy for Doubly-fed Induction Generator the Rotor Cross-Coupling Voltage
    Zhou Yuanshen
    PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 5, 2008, : 174 - 179
  • [26] Improved Control Strategy for Inertia and Primary Frequency Regulation of Doubly Fed Induction Generator Based on Rotor Kinetic Energy and Supercapacitor Energy Storage
    Yan X.
    Sun X.
    Cui S.
    Li X.
    Li T.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 : 179 - 190
  • [27] Research on doubly-fed induction generator with adaptive rotor flux observer
    Xu, Xiang-Hong
    Yin, Ming
    MECHANICS AND ARCHITECTURAL DESIGN, 2017, : 644 - 649
  • [28] Unbalanced fault diagnosis of rotor winding in doubly-fed induction generator
    Ma H.-Z.
    Li S.-Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (02): : 138 - 143
  • [29] Frequency dependent strategy for mitigating wind power fluctuations of a doubly-fed induction generator wind turbine based on virtual inertia control and blade pitch angle regulation
    Ochoa, Danny
    Martinez, Sergio
    RENEWABLE ENERGY, 2018, 128 : 108 - 124
  • [30] Theoretical and Experimental Research on Vibration Characteristics of the Doubly-Fed Induction Generator for Wind Turbine
    Zhao, Ping
    Li, Xiaoguang
    Yang, Jun
    Yang, Liu
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON CYBERNETICS, ROBOTICS AND CONTROL (CRC), 2016, : 60 - 64