The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes

被引:1
|
作者
Huang, Zhang-Wei [1 ]
Yang, Gui-Lin [1 ]
Li, Qing [2 ]
Tang, Bo [1 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 2, Dept Vasc Abdominal & Hernia Surg, 76 Linjiang Rd, Chongqing, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 2, Dept Hematol, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
PREVENTION; EXPERIENCE; OBESITY;
D O I
10.1016/j.avsg.2024.06.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We aimed to investigate the potential correlation between the placement factors of various retrievable inferior vena cava filters and retrieval outcomes. Additionally, we aimed to identify the factors affecting the placement tilt of the filter. Methods: This retrospective study was conducted at a tertiary care center to investigate patients who had previously undergone retrievable filter placement at our center and who subsequently had their filters removed between January 2020 and December 2021. Patient characteristics and filter-related factors were recorded. Complex filter retrieval was defined as cases that required a minimum of 8 minutes of fluoroscopy or that involved advanced techniques. Regression models were used to explore patient- and placement procedure-related factors that could influence retrieval outcomes and the placement tilt angle. Results: The study included 163 patients, and all filters were successfully retrieved. Thirtyseven (22.7%) retrievals were classified as complex retrievals. The mean diameter of the inferior vena cava in the preplacement position for the entire cohort was 16 +/- 1.8 mm. The median filter tilt angles at placement and retrieval were 5.0 degrees (IQR, 1.8 degrees-9 degrees) and 4.6 degrees (IQR, 2.1 degrees-8.0 degrees), respectively. The placement tilt angle was not significantly associated with complex retrieval (P - 0.59). The filter hook abutment to the vena cava wall (OR, 10.76, P - 0.003), dwell time (OR, 1.02, P - 0.029), and diameter of the vena cava (OR, 10.21, P < 0.001) were associated with complex retrieval. The diameter (P - 0.049), age (P - 0.049), and filter brand (P - 0.001) were found to be significantly associated with placement tilt. Conclusions: The inferior vena cava diameter at the time of placement predicts difficulty in filter retrieval. In addition, the filter hook abutting the inferior vena cava wall and long indwelling time may complicate retrieval. The vena cava diameter is also closely related to the degree of filter tilt.
引用
收藏
页码:564 / 571
页数:8
相关论文
共 50 条
  • [41] Costs and complications of endovascular inferior vena cava filter retrieval
    Brahmandam, Anand
    Skrip, Laura
    Mojibian, Hamid
    Aruny, John
    Sumpio, Bauer
    Dardik, Alan
    Sarac, Timur
    Chaar, Cassius Iyad Ochoa
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2019, 7 (05) : 653 - +
  • [42] Endovascular Retrieval of Inferior Vena Cava Filter Penetrating Duodenum
    Shafique, Shoaib
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (04) : 1114 - 1115
  • [43] Factors Affecting Inferior Vena Cava Filter Retrieval: A Review
    Crumley, Kristen D.
    Hyatt, Eddie
    Kalva, Sanjeeva P.
    Shah, Hriday
    VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (03) : 224 - 229
  • [44] Assessing the rate of inferior vena cava filter use and retrieval
    Osinbowale, Olusegun
    Ahsan, Syed
    VASCULAR MEDICINE, 2014, 19 (03) : 232 - 232
  • [45] Successful retrieval of a Ionglasting temporary inferior vena cava filter
    Couturier, M.
    Annweiler, T.
    Bertoletti, L.
    Barral, F. -G.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 481 - 482
  • [46] Cardiac tamponade: A complication of inferior vena cava filter retrieval
    Liang, Jackson J.
    Mankad, Sunil V.
    Johnson, C. Michael
    Cooper, Leslie T.
    VASCULAR MEDICINE, 2014, 19 (03) : 241 - 242
  • [47] Complex Hybrid Suprarenal Inferior Vena Cava Filter Retrieval
    Chou, Elizabeth L.
    Sgroi, Michael D.
    Fujitani, Roy M.
    Kabutey, Nii-Kabu
    ANNALS OF VASCULAR SURGERY, 2015, 29 (01)
  • [48] Percutaneous Retrieval of an Inferior Vena Cava Filter Penetrating Into the Duodenum
    Gibo, Hiroyuki
    Saito, Shota
    Koya, Jiro
    Yasui, Yutaro
    Tokuda, Yusuke
    Sugitatsu, Kazuya
    Makita, Yasuhiro
    Suzuki, Kazuharu
    Miyamoto, Shuichi
    Shoda, Morio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (12) : E131 - E133
  • [49] Is a Venacavogram Necessary after Inferior Vena Cava Filter Retrieval?
    Mintz, Joseph D.
    Stavropoulos, S. William
    Trerotola, Scott O.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (12) : 1857 - 1864
  • [50] Iatrogenic injury following retrieval of an inferior vena cava filter
    Eckersley, Martyn
    Balmforth, Damian
    Hambly, James John
    Aktuerk, Dincer
    ANZ JOURNAL OF SURGERY, 2022, 92 (7-8) : 1891 - 1892