The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes

被引:1
|
作者
Huang, Zhang-Wei [1 ]
Yang, Gui-Lin [1 ]
Li, Qing [2 ]
Tang, Bo [1 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 2, Dept Vasc Abdominal & Hernia Surg, 76 Linjiang Rd, Chongqing, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 2, Dept Hematol, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
PREVENTION; EXPERIENCE; OBESITY;
D O I
10.1016/j.avsg.2024.06.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We aimed to investigate the potential correlation between the placement factors of various retrievable inferior vena cava filters and retrieval outcomes. Additionally, we aimed to identify the factors affecting the placement tilt of the filter. Methods: This retrospective study was conducted at a tertiary care center to investigate patients who had previously undergone retrievable filter placement at our center and who subsequently had their filters removed between January 2020 and December 2021. Patient characteristics and filter-related factors were recorded. Complex filter retrieval was defined as cases that required a minimum of 8 minutes of fluoroscopy or that involved advanced techniques. Regression models were used to explore patient- and placement procedure-related factors that could influence retrieval outcomes and the placement tilt angle. Results: The study included 163 patients, and all filters were successfully retrieved. Thirtyseven (22.7%) retrievals were classified as complex retrievals. The mean diameter of the inferior vena cava in the preplacement position for the entire cohort was 16 +/- 1.8 mm. The median filter tilt angles at placement and retrieval were 5.0 degrees (IQR, 1.8 degrees-9 degrees) and 4.6 degrees (IQR, 2.1 degrees-8.0 degrees), respectively. The placement tilt angle was not significantly associated with complex retrieval (P - 0.59). The filter hook abutment to the vena cava wall (OR, 10.76, P - 0.003), dwell time (OR, 1.02, P - 0.029), and diameter of the vena cava (OR, 10.21, P < 0.001) were associated with complex retrieval. The diameter (P - 0.049), age (P - 0.049), and filter brand (P - 0.001) were found to be significantly associated with placement tilt. Conclusions: The inferior vena cava diameter at the time of placement predicts difficulty in filter retrieval. In addition, the filter hook abutting the inferior vena cava wall and long indwelling time may complicate retrieval. The vena cava diameter is also closely related to the degree of filter tilt.
引用
收藏
页码:564 / 571
页数:8
相关论文
共 50 条
  • [1] Suprarenal Inferior Vena Cava Filter Placement and Retrieval: Safety Analysis
    Baheti, Aparna
    Sheeran, Daniel
    Patrie, James
    Sabri, Saher S.
    Angle, John F.
    Wilkins, Luke R.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (02) : 231 - 235
  • [2] Inferior vena cava filter placement: Preinsertion inferior vena cava imaging
    Matthews, BD
    Joels, CS
    LeQuire, MH
    AMERICAN SURGEON, 2003, 69 (08) : 649 - 653
  • [3] Challenging Inferior Vena Cava Filter Retrieval
    Foley, Paul J.
    Wang, Grace J.
    Herdrich, Benjamin J.
    Murphy, Erin H.
    Landau, Bruce P.
    Woo, Edward Y.
    Fairman, Ronald M.
    Jackson, Benjamin M.
    JOURNAL OF VASCULAR SURGERY, 2012, 55 (06) : 25 - 26
  • [4] Improving Inferior Vena Cava Filter Retrieval Rates: Impact of a Dedicated Inferior Vena Cava Filter Clinic
    Minocha, Jeet
    Idakoji, Ibrahim
    Riaz, Ahsun
    Karp, Jennifer
    Gupta, Ramona
    Chrisman, Howard B.
    Salem, Riad
    Ryu, Robert K.
    Lewandowski, Robert J.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (12) : 1847 - 1851
  • [5] National Trends in Inferior Vena Cava Filter Placement and Retrieval Reflect a Significant Increase in Filter Retrieval Rates
    Belkin, Nathan
    Damrauer, Scott M.
    Jackson, Benjamin M.
    Foley, Paul
    Golden, Michael A.
    Fairman, Ronald M.
    Wang, Grace J.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E254 - E254
  • [6] Reply to: Inferior Vena Cava Filter Placement and Retrieval in a Patient with Dual IVC
    Ziv Haskal
    Bogdan Iliescu
    CardioVascular and Interventional Radiology, 2013, 36 : 1718 - 1718
  • [7] Letter: Inferior Vena Cava Filter Placement and Retrieval in a Patient with Dual IVC
    G. Collin
    J. S. Freedman
    CardioVascular and Interventional Radiology, 2013, 36 : 1714 - 1717
  • [8] Letter: Inferior Vena Cava Filter Placement and Retrieval in a Patient with Dual IVC
    Collin, G.
    Freedman, J. S.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (06) : 1714 - 1717
  • [9] Reply to: Inferior Vena Cava Filter Placement and Retrieval in a Patient with Dual IVC
    Haskal, Ziv
    Iliescu, Bogdan
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (06) : 1718 - 1718
  • [10] Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists
    Guez, David
    Hansberry, David R.
    Eschelman, David J.
    Gonsalves, Carin F.
    Parker, Laurence
    Rao, Vijay M.
    Levin, David C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (04) : 482 - 485