Racial Differences in the Diagnostic Accuracy of OCT Angiography Macular Vessel Density for Glaucoma

被引:2
|
作者
Gunasegaran, Gopikasree [1 ]
Moghimi, Sasan [1 ]
Nishida, Takashi [1 ]
Walker, Evan [1 ]
Kamalipour, Alireza [1 ]
Wu, Jo-Hsuan [1 ]
Mahmoudinezhad, Golnoush [1 ]
Zangwill, Linda M. [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, Viterbi Family Dept Ophthalmol, 9415 Campus Point Dr, La Jolla, CA 92093 USA
来源
OPHTHALMOLOGY GLAUCOMA | 2024年 / 7卷 / 02期
关键词
Area under curve; Glaucoma; Macular vessel density; OCTA; Race; COHERENCE TOMOGRAPHY ANGIOGRAPHY; FOVEAL AVASCULAR ZONE; OPEN-ANGLE GLAUCOMA; AFRICAN DESCENT; OPTIC-NERVE; PERFUSION DENSITY; CAPILLARY DENSITY; LAYER THICKNESS; RACE; ASSOCIATION;
D O I
10.1016/j.ogla.2023.09.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the diagnostic accuracy of macular vessel density (VD) measured by OCT angiography (OCTA) in individuals of African descent (AD) and European descent (ED) with open-angle glaucoma. Design: Observational, cross sectional study. Participants: A total of 176 eyes of 123 patients with glaucoma and 140 eyes of 88 healthy participants from the Diagnostic Innovations in Glaucoma Study. Methods: Whole-image ganglion cell complex (wiGCC) thickness and macular VD (parafoveal VD and perifoveal VD) were obtained from 6 x 6 macula scans. Area under the receiver operating characteristic (AUROC) curves were used to evaluate the diagnostic accuracy of macular VD and ganglion cell complex (GCC) thickness in AD and ED participants after adjusting for confounders such as age, visual field mean deviation (VF MD), signal strength index, axial length, self-reported hypertension and diabetes. Main Outcome Measures: Macular VD and wiGCC measurements. Results: Parafoveal and perifoveal VD were significantly lower in ED than AD patients with glaucoma. Parafoveal and perifoveal VD performed significantly worse in AD participants compared with ED participants for detection of glaucoma (adjusted AUROC, 0.75 [95% confidence interval (CI), 0.62, 0.87], 0.85 [95% CI, 0.79, 0.90], P = 0.035; and 0.82 [95% CI, 0.70, 0.92], 0.91 [95% CI, 0.87, 0.94], respectively; P = 0.020). In contrast to VD, diagnostic accuracy of GCC thickness was similar in AD and ED individuals (adjusted AUROC, 0.89 [95% CI, 0.79, 0.96], 0.92 [95% CI, 0.86, 0.96], respectively; P = 0.313). The diagnostic accuracies of both macular VD and GCC thickness for differentiating between glaucoma and healthy eyes increased with increasing VF MD in both AD and ED participants. Conclusions: Diagnostic performance of OCTA macular VD, but not GCC thickness, for glaucoma detection varies by race. Moreover, macular VD parameters had lower accuracy for detecting glaucoma in AD individuals than in ED individuals. The diagnostic performance of macular VD is race-dependent, and, therefore, race should be taken into consideration when interpreting macular OCTA results.
引用
收藏
页码:197 / 205
页数:9
相关论文
共 50 条
  • [41] Swept-source OCT angiography imaging of the macular capillary network in glaucoma
    Akil, Handan
    Chopra, Vikas
    Al-Sheikh, Mayss
    Falavarjani, Khalil Ghasemi
    Huang, Alex S.
    Sadda, SriniVas R.
    Francis, Brian A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (04) : 515 - 519
  • [42] Differences in swept-source OCT angiography of the macular capillary network in high tension and normal tension glaucoma.
    Mursch-Edlmayr, Anna Sophie
    Waser, Klemens
    Podkowinski, Dominika
    Bolz, Matthias
    CURRENT EYE RESEARCH, 2020, 45 (09) : 1168 - 1172
  • [43] Meta-analysis of Stratus OCT Glaucoma Diagnostic Accuracy
    Chen, Hsin-Yi
    Chang, Yue-Cune
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (09) : 1129 - 1139
  • [44] Peripapillary and Macular Vessel Density in Unilateral Early Pseudoexfoliation Glaucoma
    Solmaz, Nilgun
    Oba, Turker
    JOURNAL OF GLAUCOMA, 2024, 33 (12) : 964 - 972
  • [45] Topographic Differences in Superficial Macular Vessel Density in Eyes with Early Primary Open-Angle Glaucoma and Normal Tension Glaucoma
    Huo, Yan-Jiao
    Thomas, Ravi
    Guo, Yan
    Zhang, Wei
    Li, Lei
    Cao, Kai
    Wang, Huai-Zhou
    Wang, Ning-Li
    OPHTHALMIC RESEARCH, 2023, 66 (01) : 465 - 473
  • [46] Macular capillary perfusion density and macular vessel density in open-angle glaucoma and ocular hypertension: a quantitative study using optical coherence tomography angiography
    Schilt-Catafal, Maria del Mar
    Perez-Torregrosa, Vicente T.
    Duch-Samper, Antonio M.
    ACTA OPHTHALMOLOGICA, 2021, 99
  • [47] Diagnostic Accuracy of Spectral-Domain OCT Circumpapillary, Optic Nerve Head, and Macular Parameters in the Detection of Perimetric Glaucoma
    McCann, Paul
    Hogg, Ruth E.
    Wright, David M.
    McGuinness, Bernadette
    Young, Ian S.
    Kee, Frank
    Azuara-Blanco, Augusto
    OPHTHALMOLOGY GLAUCOMA, 2019, 2 (05): : 336 - 345
  • [48] Impact of Directional OCT Angiography on Retinal and Choriocapillaris Vessel Density Measurements
    Shi, Yue
    Borrelli, Enrico
    Sadda, Srinivas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [49] Analysis of peripapillary vessel density and Bruch’s membrane opening-based neuroretinal rim parameters in glaucoma using OCT and OCT-angiography
    Philip Enders
    Valentina Longo
    Werner Adler
    Jens Horstmann
    Friederike Schaub
    Thomas Dietlein
    Claus Cursiefen
    Ludwig M. Heindl
    Eye, 2020, 34 : 1086 - 1093
  • [50] Analysis of peripapillary vessel density and Bruch's membrane opening-based neuroretinal rim parameters in glaucoma using OCT and OCT-angiography
    Enders, Philip
    Longo, Valentina
    Adler, Werner
    Horstmann, Jens
    Schaub, Friederike
    Dietlein, Thomas
    Cursiefen, Claus
    Heindl, Ludwig M.
    EYE, 2020, 34 (06) : 1086 - 1093