Highly Sensitive and Flexible Copper Oxide/Graphene Non-Enzymatic Glucose Sensor by Laser Direct Writing

被引:1
|
作者
Li, Qi [1 ]
Yang, Dasheng [1 ]
Gao, Yang [1 ,2 ]
Wang, Ziyang [1 ]
Yin, Ruixue [1 ]
Xuan, Fuzhen [1 ,3 ]
机构
[1] East China Univ Sci & Technol, Sch Mech & Power Engn, Shanghai 200237, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan 430074, Hubei, Peoples R China
[3] East China Univ Sci & Technol, Shanghai Collabrat Ctr High end Equipment Reliabil, Shanghai 200237, Peoples R China
来源
ADVANCED SENSOR RESEARCH | 2023年 / 2卷 / 06期
关键词
copper oxide; flexible sensors; glucose detection; graphene; laser direct writing; CU NANOPARTICLES; EFFICIENT; NI; PERFORMANCE; FABRICATION; DEPOSITION; FILMS; OXIDE;
D O I
10.1002/adsr.202200067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and convenient detection of human blood glucose levels is an effective method for early diagnosis of diabetes and prevention of complications. The flexible and wearable electrochemical glucose sensor with low cost, fast responsiveness, good stability, reliability, and high sensitivity has attracted much attention in monitoring glucose concentration. The preparation of a conductive layer with catalytic activity on a flexible substrate is the key to making a wearable glucose sensor. Here, graphene composite materials sintered with copper oxide (CuO) nanoparticles are successfully prepared on a polyimide film by laser direct writing method and fabricated a flexible non-enzymatic glucose sensor using laser-engraved graphene (LEG) as a conductive electrode. The CuO/LEG sensor exhibits a high sensitivity of 619.43 mu A mm-1 cm-2 in 0-3 mm glucose and 462.96 mu A mm-1 cm-2 in 0-8 mm glucose. In addition, the CuO/LEG sensor shows good reproducibility, high anti-interference capability, and long-term stability. It also presents good bending stability, which can maintain 82.40% initial current after 100 times bending. Moreover, the CuO/LEG sensor has an obvious step-ampere response in the detection of sweat samples, indicating the great potential of wearable sweat sensors. A high-performance copper oxide (CuO)/laser-engraved graphene (LEG) based non-enzymatic glucose sensor is prepared by laser direct writing method. The CuO/LEG sensor exhibits a high sensitivity of 619.43 mu A mm-1 cm-2 in 0-3 mm glucose and 462.96 mu A mm-1 cm-2 in 0-8 mm glucose. Moreover, the CuO/LEG sensor also shows good selectivity, reproducibility, long-term stability, and bending stability. image
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor
    Li, Longxiao
    Han, Yufei
    Zhang, Yuzhe
    Wu, Weijia
    Du, Wei
    Wen, Guojun
    Cheng, Siyi
    MOLECULES, 2024, 29 (23):
  • [22] Copper oxide nanocolumns for high-sensitive non-enzymatic glucose sensing
    Amirsoleimani, Amir R.
    Siampour, Hossein
    Abbasian, Sara
    Rad, Garshasb Behmaneshi
    Moshaii, Ahmad
    Zaradshan, Zahra
    SENSING AND BIO-SENSING RESEARCH, 2023, 42
  • [23] Salivary Glucose Detection with Laser Induced Graphene/AgNPs Non-Enzymatic Sensor
    Aparicio-Martinez, Eider Pedro
    Vega-Rios, Alejandro
    Osuna, Velia
    Dominguez, Rocio Berenice
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [24] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Anand, Vijay Kumar
    Bukke, Archana
    Bhatt, Kapil
    Kumar, Sandeep
    Sharma, Sandeep
    Goyal, Rakesh
    Virdi, G. S.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (07):
  • [25] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Vijay Kumar Anand
    Archana Bukke
    Kapil Bhatt
    Sandeep Kumar
    Sandeep Sharma
    Rakesh Goyal
    G. S. Virdi
    Applied Physics A, 2020, 126
  • [26] Highly sensitive non-enzymatic glucose sensor based on carbon nanotube microelectrode set
    Gupta, Pankaj
    Gupta, Vandna K.
    Huseinov, Artur
    Rahm, Connor E.
    Gazica, Kiera
    Alvarez, Noe T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [27] Highly sensitive non-enzymatic electrochemical glucose sensor surpassing water oxidation interference
    Thakur, Neha
    Mandal, Debaprasad
    Nagaiah, Tharamani C.
    JOURNAL OF MATERIALS CHEMISTRY B, 2021, 9 (40) : 8399 - 8405
  • [28] Highly exposed copper oxide supported on three-dimensional porous reduced graphene oxide for non-enzymatic detection of glucose
    Zhao, Yue
    Bo, Xiangjie
    Guo, Liping
    ELECTROCHIMICA ACTA, 2015, 176 : 1272 - 1279
  • [29] Highly sensitive non-enzymatic MP sensor based on electrospun copper oxide-doped zirconium oxide composite microfibers
    Li, Ling
    Wang, Zhihui
    Wang, Tingting
    Gong, Jian
    Qi, Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 846
  • [30] Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide
    Wu, Geng-huang
    Song, Xin-hong
    Wu, Yan-fan
    Chen, Xiao-mei
    Luo, Feng
    Chen, Xi
    TALANTA, 2013, 105 : 379 - 385