Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position

被引:1
|
作者
Okamoto, Masanori [1 ]
Takegami, Yasuhiko [2 ]
Osawa, Yusuke [2 ]
Tanaka, Shinya [2 ]
Nobori, Tatsuya [1 ]
Imagama, Shiro [2 ]
机构
[1] Yokkaichi Municipal Hosp, Dept Orthopaed Surg, 11 2-2-37,Shibata, Yokaichi, Mie 5108567, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Orthopaed Surg, 65 Tsurumai Cho,Showa Ku, Nagoya, 4668550, Japan
关键词
Hip; Total hip arthroplasty; Computer-assisted surgery; Portable navigation systems; Alignment guide; IMPROVE; THA; REGISTRATION; DYSPLASIA; OSTEOTOMY;
D O I
10.1007/s00402-024-05571-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) using a portable navigation system (PNS) incurs costs per procedure. However, it does not require a large console. This study aimed to compare the accuracy of acetabular cup placement using a pelvic alignment guide (PAG) attached to the pelvis and an accelerometer-based PNS in THA performed in the lateral decubitus position. Methods We retrospectively analyzed 100 hips that underwent primary THA in the lateral decubitus position between July 2018 and January 2021. The PAG was used in 50 hips, whereas the PNS was used in the other 50. Cup placement accuracy was measured using postoperative computed tomography scans, comparing errors in inclination and anteversion angles. The surgical time, blood loss, and complications were recorded. The follow-up period was at least 2 years in all cases. Results The mean absolute error of the inclination angle was similar between the groups (the PAG group: 3.7 degrees +/- 2.3 degrees [range, 0.0-9.0]; the PNS group: 3.7 degrees +/- 2.3 degrees [range, 0.2-10.5], p = 0.705). The mean absolute error of the anteversion angle was significantly smaller in the PAG group than in the PNS group (3.0 degrees +/- 2.4 degrees [range, 0.0-9.7] vs. 6.5 degrees +/- 4.8 degrees [range, 0.3-17.3], p < 0.001). The PAG group had a higher proportion of hips within 5 degrees and 10 degrees of the target angle (64 vs. 42%, P = 0.028, and 100 vs. 74%, p < 0.001, respectively). The PNS group had six hips with anteversion errors of 15 degrees or more. Surgical time and blood loss were lower in the PAG group. The PNS group had one dislocation, whereas the PAG group did not. Conclusion The accelerometer-based PNS did not demonstrate superior cup alignment accuracy compared to the PAG in THA performed in the lateral decubitus position. This finding informs surgeons that computer-assisted surgery is not necessarily superior to conventional THA using a PAG.
引用
收藏
页码:4849 / 4856
页数:8
相关论文
共 50 条
  • [1] A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position
    Ohyama, Yohei
    Minoda, Yukihide
    Sugama, Ryo
    Masuda, Sho
    Ohta, Yoichi
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2865 - 2872
  • [2] Augmented Reality- vs Accelerometer-Based Portable Navigation System to Improve the Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in the Lateral Decubitus Position
    Tsukada, Sachiyuki
    Ogawa, Hiroyuki
    Hirasawa, Naoyuki
    Nishino, Masahiro
    Aoyama, Hiromichi
    Kurosaka, Kenji
    JOURNAL OF ARTHROPLASTY, 2022, 37 (03): : 488 - 494
  • [3] A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions
    Ohyama, Yohei
    Sugama, Ryo
    Kim, Yuha
    Ohta, Yoichi
    Minoda, Yukihide
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4473 - 4480
  • [4] A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions
    Yohei Ohyama
    Ryo Sugama
    Yuha Kim
    Yoichi Ohta
    Yukihide Minoda
    Hiroaki Nakamura
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4473 - 4480
  • [5] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [6] Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position
    Kamenaga, Tomoyuki
    Hayashi, Shinya
    Hashimoto, Shingo
    Matsumoto, Tomoyuki
    Takayama, Koji
    Fujishiro, Takaaki
    Hiranaka, Takafumi
    Niikura, Takahiro
    Kuroda, Ryosuke
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [7] Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Matsumoto, Tomoyuki
    Kamenaga, Tomoyuki
    Maeda, Toshihisa
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 3759 - 3766
  • [8] Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Tomoyuki Matsumoto
    Tomoyuki Kamenaga
    Toshihisa Maeda
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3759 - 3766
  • [9] Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Mitsutake, Ryo
    Ito, Hiroshi
    JOURNAL OF ARTHROPLASTY, 2020, 35 (01): : 172 - 177
  • [10] Measurement accuracy of the acetabular cup position using an inertial portable hip navigation system with patients in the lateral decubitus position
    Hiromasa Tanino
    Ryo Mitsutake
    Hiroshi Ito
    Scientific Reports, 14