A novel low-cost sensors system for real-time multipollutant indoor air quality monitoring - Development and performance

被引:0
|
作者
Chojer, H. [1 ,2 ]
Branco, P. T. B. S. [1 ,2 ]
Martins, F. G. [1 ,2 ]
Sousa, S. I. V. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, LEPABE Lab Proc Engn Environment Biotechnol & Ener, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[2] Univ Porto, Fac Engn, ALiCE Associate Lab Chem Engn, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
关键词
Indoor air quality; Air quality monitoring; Calibration; Multipollutant; Low-cost sensors; FIELD CALIBRATION; AVAILABLE SENSORS; EXPOSURE; PLATFORM; CLUSTER; PART; HOME;
D O I
10.1016/j.buildenv.2024.112055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air pollution poses a significant health risk, thus demanding effective indoor air quality (IAQ) monitoring strategies. Low-cost sensors (LCS) have gained attraction for IAQ monitoring, but their data accuracy and robustness remain key challenges. This study addresses gaps in the literature by developing and evaluating a novel low-cost monitor prototype for IAQ monitoring. A detailed design methodology based on requirements analysis was used to create two identical low-cost monitors (LCM) prototypes for multipollutant monitoring, including PM2.5, CO2, CO, O-3, NO2, temperature and relative humidity. The LCM were deployed in an in-field monitoring campaign alongside research-grade instruments. The uncorrected sensor signals showed linear response compared to research-grade instruments with high Pearson Correlation Coefficients for 1-min mean: PM2.5 (0.97), CO2 (0.81-0.89), CO (0.95-0.98), and O-3 (0.80-0.85). The concentration range of pollutants was observed to play a crucial role in the response and accuracy of the LCS. Kalman filter was implemented with optimised parameters to reduce noise from the signal of ozone sensors. Univariate and multivariate linear models were used to field calibrate the sensors. Linear regression models, with high coefficients of determination (>0.8) and low error values, imply that the developed LCM prototypes can be reliably used for indicative monitoring. In most of the cases, univariate linear models using only the sensor response of LCS as explanatory variables showed significant improvement. Future work will involve longer monitoring campaigns in different microenvironments, evaluation of calibration drift and to assess failure episodes in long-term use.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment
    Kim, Jeong Ho
    Park, Ki Hyun
    Joo, Koan Sik
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (05) : 801 - 805
  • [32] Indoor air quality evaluation in oncology units at two European hospitals: Low-cost sensors for TVOCs, PM2.5 and CO2 real-time monitoring
    Palmisani, Jolanda
    Di Gilio, Alessia
    Viana, Mar
    de Gennaro, Gianluigi
    Ferro, Andrea
    BUILDING AND ENVIRONMENT, 2021, 205
  • [33] Low-Cost Hall-Effect Sensors for Real-Time Monitoring Pier Scour
    Chen, Chen-Chia
    Yang, Chih-Chyau
    Chen, Ssu-Ying
    Chen, Wen-Ching
    Sung, Gang-Neng
    Kuo, Chih-Ting
    2015 IEEE TENTH INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS AND INFORMATION PROCESSING (ISSNIP), 2015,
  • [34] Towards Low-Cost Sensors for Real-Time Monitoring of Contaminant Ions in Water Sources
    Gorji, Amin
    Kaleita, Amy
    Bowler, Nicola
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 525 - 528
  • [35] Performance of Dual-Frequencies Low-Cost GNSS Sensors for Real Time Monitoring
    Poluzzi, Luca
    Gandolfi, Stefano
    GEOMATICS AND GEOSPATIAL TECHNOLOGIES, ASITA 2021, 2022, 1507 : 246 - 258
  • [36] Internet questionnaire and real-time indoor air quality monitoring
    Kähkönen, E
    Zitting, A
    Airo, E
    Valkonen, J
    Leikas, M
    INDOOR AND BUILT ENVIRONMENT, 1997, 6 (06) : 331 - 336
  • [37] Performance evaluation of low-cost air quality sensors: A review
    Kang, Ye
    Aye, Lu
    Ngo, Tuan Duc
    Zhou, Jin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 818
  • [38] Evaluation of low-cost sensors to integrate in a water quality monitor for real-time measurements
    Slongo, Juliano
    Lindino, Cleber
    Martins, Leila D.
    Spanhol, Fabio A.
    Carneiro, Edipo
    Camargo, Edson T.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2024, 196 (08)
  • [39] Development of an air quality station using low-cost sensors
    Roncaglio, Mateus Maruzka
    de Camargo, Edson Tavares
    Martins, Leila Droprinchinski
    Oyamada, Marcio Seiji
    2023 XIII BRAZILIAN SYMPOSIUM ON COMPUTING SYSTEMS ENGINEERING, SBESC, 2023,
  • [40] Investigation of indoor air quality in university residences using low-cost sensors
    Afroz, Rowshon
    Guo, Xinyang
    Cheng, Chu-Wen
    Delorme, Ariel
    Duruisseau-Kuntz, Ryan
    Zhao, Ran
    ENVIRONMENTAL SCIENCE-ATMOSPHERES, 2023, 3 (02): : 347 - 362