Effect of Knee Angle, Contractile Activity, and Intensity of Force Production on Vastus Lateralis Stiffness: A Supersonic Shear Wave Elastography Pilot Study

被引:0
|
作者
Santos, Rute [1 ,2 ,3 ,4 ]
Valamatos, Maria Joao [1 ]
Mil-Homens, Pedro [1 ]
Armada-da-Silva, Paulo A. S. [1 ,5 ]
机构
[1] Univ Lisbon, Fac Motricidade Humana, Estr Costa, P-1499002 Lisbon, Portugal
[2] Polytech Univ Coimbra, Coimbra Hlth Sch, Lagar Cort, Rua Misericordia, P-3045093 Coimbra, Portugal
[3] Polytech Univ Coimbra, H&TRC Hlth & Technol Res Ctr, Coimbra Hlth Sch, Rua 5 Outubro, P-3045043 Coimbra, Portugal
[4] Univ Coimbra, CIPER UC Interdisciplinary Ctr Study Human Perform, P-3004531 Coimbra, Portugal
[5] Univ Lisbon, Fac Motricidade Humana, Ctr Interdisciplinar Estudo Performance Humana, Estr Costa, P-1499002 Cruz Quebrada, Portugal
关键词
supersonic shear image ultrasound; vastus lateralis muscle; elasticity; elastography; elasticity imaging techniques; ultrasonography; MUSCLE HARDNESS; ELASTIC-MODULUS; MECHANICAL-PROPERTIES; NECK; SONOELASTOGRAPHY; RANGE; AGE;
D O I
10.3390/sports12080211
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Supersonic shear image (SSI) ultrasound elastography provides a quantitative assessment of tissue stiffness using the velocity of shear waves. SSI's great potential has allowed researchers in fields like biomechanics and muscle physiology to study the function of complex muscle groups in different conditions. The aim of this study is to use SSI to investigate changes in the stiffness of the vastus lateralis (VL) muscle as a consequence of passive elongation, isometric contraction, and repeated muscle activity. In a single session, 15 volunteers performed a series of isometric, concentric, and eccentric contractions. SSI images were collected from the VL to assess its stiffness before and after the contractions and at various knee angles. Two-way within-subjects ANOVA was used to test the effects of muscle contraction type and knee angle on VL stiffness. Linear regression analysis was employed to assess the relationship between muscle stiffness and the intensity of isometric contractions. After maximal contractions, VL stiffness increased by approximately 10% compared to baseline values, and following maximal isometric (p < 0.01) and eccentric contractions (p < 0.05). Yet, there was no change in VL shear modulus at the end of concentric contractions. The relaxed VL shear modulus increased with knee flexion both before and after the knee extensor contractions (p < 0.001). A linear relationship between the shear modulus and the degree of isometric contraction was observed, although with notable individual variation (R-2 = 0.125). Maximal contractile activity produces modest increases in relaxed muscle stiffness. The SSI-measured shear modulus increases linearly with the degree of isometric contraction.
引用
收藏
页数:11
相关论文
共 32 条
  • [31] Point shear wave elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI) imaging: a feasibility study and norm values for renal parenchymal stiffness in healthy children and adolescents
    Grass, Lilian
    Szekely, Nora
    Alrajab, Abdulsattar
    Thi Thanh Tam Bui-Ta
    Hoffmann, Georg F.
    Wuehl, Elke
    Schenk, Jens Peter
    MEDICAL ULTRASONOGRAPHY, 2017, 19 (04) : 366 - 373
  • [32] Quantitative Assessment of Liver Stiffness Using Ultrasound Shear Wave Elastography in Patients With Chronic Graft-Versus-Host Disease After Allogeneic Hematopoietic Stem Cell Transplantation: A Pilot Study
    Zhang, Man
    Mendiratta-Lala, Mishal
    Maturen, Katherine E.
    Wasnik, Ashish P.
    Wang, Sherry S.
    Assad, Hadeel
    Rubin, Jonathan M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 455 - 461