Charge Variants Characterization of Co-Formulated Antibodies by Three-Dimensional Liquid Chromatography-Mass Spectrometry

被引:0
|
作者
Jin, Xiaoqing [1 ]
Chen, Luna [1 ]
Chu, Jianlin [2 ]
He, Bingfang [1 ,2 ]
机构
[1] Nanjing Tech Univ, Coll Biotechnol & Pharmaceut Engn, Nanjing 211816, Peoples R China
[2] Nanjing Tech Univ, Sch Pharmaceut Sci, Nanjing 211816, Peoples R China
关键词
charge variants; co-formulated antibodies; characterization; 3D-LC-MS; PHARMACOKINETICS; COMBINATION; PERTUZUMAB;
D O I
10.3390/biom14080999
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Co-formulated antibodies can bring clinical benefits to patients by combining two or more antibodies in a single dosage form. However, the quality analysis of co-formulated antibodies raises additional challenges, compared to individual antibodies, due to the need for accurate analysis of multiple antibodies in one solution. It is extremely difficult to effectively separate the charge variants of the two co-formulated antibodies using one ion exchange chromatography (IEC) method because of their similar characteristics. In this study, a novel method was developed for the charge variants characterization of co-formulated antibodies using three-dimensional liquid chromatography-mass spectrometry (3D-LC-MS). Hydrophobic interaction chromatography (HIC) was used as the first dimension to separate and collect the two co-formulated antibodies. The two collections were then injected into the second-dimension IEC separately for charge variants separation and analysis. Subsequently, the separated charge variants underwent on-line desalting in the third-dimension reverse-phase chromatography (RPC) and subsequent mass spectroscopy analysis. The novel method could simultaneously provide a charge variants ratio and post-translational modification (PTM) data for the two co-formulated antibodies. Therefore, it could be used for release testing and stability studies of co-formulated antibodies, making up for the shortcomings of the existing approaches. It was the first time that charge variants of co-formulated antibodies were characterized by the 3D-LC-MS method, to the best of our knowledge.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Characterization of Gangliosides in Biological Samples
    Hajek, Roman
    Jirasko, Robert
    Lisa, Miroslav
    Cifkova, Eva
    Holcapek, Michal
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12425 - 12432
  • [32] Liquid chromatography-mass spectrometry hyphenation for exhaustive and unambiguous characterization of polyoxyethylene surfactants
    Cheguillaume, G
    Buchmann, W
    Desmazières, B
    Tortajada, J
    CHROMATOGRAPHIA, 2004, 60 (9-10) : 561 - 566
  • [33] Three-dimensional cell bioreactor coupled with high performance liquid chromatography-mass spectrometry for the affinity screening of bioactive components from herb medicine
    Mou, Zhao-Li
    Qi, Xiao-Ni
    Liu, Rui-Lin
    Zhang, Jing
    Zhang, Zhi-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1243 : 33 - 38
  • [34] Characterization of anthocyanins in grape juices by ion trap liquid chromatography-mass spectrometry
    Wang, HB
    Race, EJ
    Shrikhande, AJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (07) : 1839 - 1844
  • [35] Enrichment and characterization of histones by two-dimensional hydroxyapatite/reversed-phase liquid chromatography-mass spectrometry
    Su, Xiaodan
    Jacob, Naduparambil K.
    Amunugama, Ravindra
    Hsu, Pang-Hung
    Fishel, Richard
    Freitas, Michael A.
    ANALYTICAL BIOCHEMISTRY, 2009, 388 (01) : 47 - 55
  • [36] Comprehensive three-dimensional gas chromatography mass spectrometry separation of diesel
    Wang, Frank Cheng-Yu
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1489 : 126 - 133
  • [37] Characterization of monoclonal antibodies by a fast and easy liquid chromatography-mass spectrometry time-of-flight analysis on culture supernatant
    Henninot, Antoine
    Terrier, Aurelie
    Charton, Julie
    Urbain, Remi
    Fontayne, Alexandre
    Deprez, Benoit
    Beghyn, Terence
    ANALYTICAL BIOCHEMISTRY, 2015, 491 : 52 - 54
  • [38] Non-targeted metabolomics study for the analysis of chemical compositions in three types of tea by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry
    Zhang Lei
    Zeng Zhongda
    Ye Guozhu
    Zhao Chunxia
    Lu Xin
    Xu Guowang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (08) : 804 - 816
  • [39] Two-dimensional method for time aligning liquid chromatography-mass spectrometry data
    Suits, Frank
    Lepre, Jorge
    Du, Peicheng
    Bischoff, Rainer
    Horvatovich, Peter
    ANALYTICAL CHEMISTRY, 2008, 80 (09) : 3095 - 3104
  • [40] Signal and charge enhancement for protein analysis by liquid chromatography-mass spectrometry with desorption electrospray ionization
    Liu, Yan
    Miao, Zhixin
    Lakshmanan, Rajeswari
    Loo, Rachel R. Ogorzalek
    Loo, Joseph A.
    Chen, Hao
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 : 161 - 166