The use of Fibrin Sealants in Reducing Drain Output in Abdominoplasty: Is it Useful?

被引:0
|
作者
Pieretti, G. [1 ]
Gubitosi, A. [1 ]
Mazzarella, V. [1 ]
Cimmino, M. [1 ]
Lanzano, G. [1 ]
Grella, R. [1 ]
Ferraro, G. A. [1 ]
Grella, E. [1 ]
机构
[1] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Specialties, Plast Surg Unit, Piazza Luigi Miraglia, I-80138 Naples, Italy
来源
JPRAS OPEN | 2024年 / 41卷
关键词
abdominoplasty; postbariatric surgery; fibrin sealant; fibrin glue; drain output; bleeding; exudation; BODY CONTOURING SURGERY; MASSIVE WEIGHT-LOSS; SEROMA FORMATION; BARIATRIC SURGERY; COMPLICATIONS; GLUE; EXPERIENCE; METAANALYSIS; OBESE;
D O I
10.1016/j.jpra.2024.06.001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background:<bold> </bold>Abdominoplasty is a common surgical procedure in which excess abdominal skin and fat are reduced to improve body contouring. Fibrin sealant has been proposed to reduce postsurgical bleeding and exudation. In this study, we evaluated whether there was a significant statistical difference in surgical output between the use of fibrin glue and its nonuse in abdominoplasty surgery, specifically in reducing bleeding and exudation. Material and methods:<bold> </bold>A retrospective chart review of 68 postbariatric abdominoplasty patients (58 females, 10 males) was performed. We divided the patients into Group A (30 cases, 44%), in which we used fibrin sealant, and Group B (38 cases, 56%), in which we did not use fibrin glue. We calculated the total amount of liquid in suction drainages until the day of their removal. Statistical analysis included the independent t-test with a significance level of 0.05. Results:<bold> </bold>The average drainage output in Group A was 620.0 +/- 375.0 mL, whereas in Group B, it was 500.0 +/- 290.0 mL. Results indicate an insignificant correlation between the use of fibrin glue and the amount of liquid in the surgical drains (t = 1.52, p = 0.13). The result is not significant at p <.05 according to the independent t-test. Conclusion:<bold> </bold>The use of fibrin sealant surely has a high value in all surgical branches to reduce postoperative complications, but in our study, we did not find any advantages in its use for reducing surgical drain output in abdominoplasty patients.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 47 条
  • [21] The Use of a Fibrin Glue with a Low Concentration of Thrombin Decreases Seroma Formation in Postbariatric Patients Undergoing Circular Abdominoplasty
    Pilone, Vincenzo
    Vitiello, Antonio
    Borriello, Ciro
    Gargiulo, Stefano
    Forestieri, Pietro
    OBESITY SURGERY, 2015, 25 (02) : 354 - 359
  • [22] The Use of a Fibrin Glue with a Low Concentration of Thrombin Decreases Seroma Formation in Postbariatric Patients Undergoing Circular Abdominoplasty
    Vincenzo Pilone
    Antonio Vitiello
    Ciro Borriello
    Stefano Gargiulo
    Pietro Forestieri
    Obesity Surgery, 2015, 25 : 354 - 359
  • [23] Determining the Effectiveness of Fibrin Sealants in Reducing Complications in Patients Undergoing Lateral Neck Dissection (DEFeND): A Randomised External Pilot Trial
    Bajwa, Mandeep S.
    Jackson, Richard
    Dhanda, Jagtar
    Smith, Catrin Tudur
    Shaw, Richard J.
    Schache, Andrew G.
    CANCERS, 2023, 15 (20)
  • [24] Effectiveness of Fibrin Sealant Patch in Reducing Drain Volume after Pelvic Lymph Node Dissection in Women with Gynecologic Malignancy
    Kim, Hwa Cheong
    Choi, Chahien
    Kim, Woo Young
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [25] A Carrier Drain Structure for Reducing the Output Noise of Sillicon Photomultipliers after Exposure to Strong Incident Light
    Okamoto, Kazuaki
    Fujiwara, Ikuo
    Shimizu, Mariko
    Kwon, Honam
    Sasaki, Keita
    Suzuki, Kazuhiro
    2021 ANNUAL CONFERENCE OF THE IEEE PHOTONICS SOCIETY (IPC), 2021,
  • [26] The Use of ARTISS (Fibrin Sealant Spray) to Facilitate a Day-case Drain-less Mastectomy
    Cullen, J.
    Razi, K.
    Arbis, A.
    Shah, E.
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 26 - 26
  • [27] Effect of fibrin sealant on drain output and duration of hospitalization after multilevel anterior cervical fusion - A retrospective matched pair analysis
    Yeom, Jin S.
    Buchowski, Jacob M.
    Shen, Hong Xing
    Liu, Gabriel
    Bunmaprasert, Torphong
    Riew, K. Daniel
    SPINE, 2008, 33 (16) : E543 - E547
  • [28] Does fibrin sealant reduce drain output and allow earlier removal of drainage catheters in women undergoing operation for breast cancer?
    Langer, S
    Guenther, JM
    DiFronzo, LA
    AMERICAN SURGEON, 2003, 69 (01) : 77 - 81
  • [29] Determining the effectiveness of fibrin sealants in reducing complications in patients undergoing lateral neck dissection (DEFeND): study protocol for a randomised external pilot trial
    Mandeep S. Bajwa
    Stacey Carruthers
    Rob Hanson
    Richard Jackson
    Chris Braithwaite
    Mike Edwards
    Seema Chauhan
    Catrin Tudur Smith
    Richard J. Shaw
    Andrew G. Schache
    Pilot and Feasibility Studies, 6
  • [30] Determining the effectiveness of fibrin sealants in reducing complications in patients undergoing lateral neck dissection (DEFeND): study protocol for a randomised external pilot trial
    Bajwa, Mandeep S.
    Carruthers, Stacey
    Hanson, Rob
    Jackson, Richard
    Braithwaite, Chris
    Edwards, Mike
    Chauhan, Seema
    Smith, Catrin Tudur
    Shaw, Richard J.
    Schache, Andrew G.