Simultaneous high-pitch multi-energy CT pulmonary angiography using a dual-source photon-counting-detector CT: A phantom experiment

被引:2
|
作者
Mihailovic, Jelena M. [1 ]
Bruesewitz, Michael R. [1 ]
Swicklik, Joseph R. [1 ]
Yalon, Mariana [1 ]
Rajiah, Prabhakar S. [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia H. [1 ]
Yu, Lifeng [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
来源
关键词
dual source computed tomography; photon-counting-detector computed tomography; pulmonary embolism; PERFUSED BLOOD-VOLUME; ENERGY CT; EMBOLISM;
D O I
10.1002/acm2.14496
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A dual-source CT system can be operated in a high-pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi-energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy-integrating detector (EID) CT can perform simultaneous ME and high-pitch acquisition. This phantom study aimed to evaluate the ability of a photon-counting-detector (PCD) CT to perform simultaneous high-pitch and ME imaging for CTPA. Methods: A motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high-pitch and ME EID-CT scans and a single high-pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images. Results: When there was motion, EID-CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD-CT in high-pitch ME were more stable when there was a motion, with a lower standard deviation than EID-CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID-CT, while PCD-CT high-pitch ME mode showed good agreement between measurements on static or moving images. Conclusion: PCD-CT with combined ME and high-pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance
    Tao, Ashley
    Huang, Richard
    Tao, Shengzhen
    Michalak, Gregory J.
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [32] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bernhard Bischoff
    Felix G. Meinel
    Maximilian Reiser
    Hans-Christoph Becker
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1159 - 1165
  • [33] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bischoff, Bernhard
    Meinel, Felix G.
    Reiser, Maximilian
    Becker, Hans-Christoph
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1159 - 1165
  • [34] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [35] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Martin Beeres
    Boris Schell
    Aristidis Mastragelopoulos
    Eva Herrmann
    Josef Matthias Kerl
    Tatjana Gruber-Rouh
    Clara Lee
    Petra Siebenhandl
    Boris Bodelle
    Stephan Zangos
    Thomas J. Vogl
    Volkmar Jacobi
    Ralf W. Bauer
    European Radiology, 2012, 22 : 129 - 137
  • [36] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Yang, Wen Jie
    Chen, Ke Min
    Liu, Bo
    Pang, Li Fang
    Zhang, Huan
    Pan, Zi Lai
    Yan, Fu Hua
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 245 - 252
  • [37] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Wen Jie Yang
    Ke Min Chen
    Bo Liu
    Li Fang Pang
    Huan Zhang
    Zi Lai Pan
    Fu Hua Yan
    The International Journal of Cardiovascular Imaging, 2013, 29 : 245 - 252
  • [38] Classification of Urinary Stone Composition with a Photon-Counting-Detector CT System Used in a Simulated Dual-Source Acquisition Mode
    Michalak, G.
    Ren, L.
    Ferrero, A.
    Leng, S.
    McCollough, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E409 - E410
  • [39] Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study
    Hao, Wanting
    Xu, Zhihan
    Lin, Huimin
    Yan, Fuhua
    ACADEMIC RADIOLOGY, 2024, 31 (10) : 4119 - 4128
  • [40] Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta
    Wielandner, Alice
    Beitzke, Dietrich
    Schernthaner, Ruediger
    Wolf, Florian
    Langenberger, Christina
    Stadler, Alfred
    Loewe, Christian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):