Reduction with zinc - Impact on the determination of nitrite and nitrate ions using microfluidic paper-based analytical devices

被引:2
|
作者
Umeda, Mika I. [1 ,2 ]
Danchana, Kaewta [2 ]
Fujii, Takatoshi [1 ]
Hino, Eiichi [1 ]
Date, Yusuke [1 ]
Aoki, Kaoru [1 ]
Kaneta, Takashi [2 ]
机构
[1] Yonago Coll, Natl Inst Technol, 4448 Hikona Cho, Yonago, Tottori 6838502, Japan
[2] Okayama Univ, 3-1-1 Tsushimanaka,Kita ku, Okayama 7008530, Japan
来源
TALANTA OPEN | 2024年 / 10卷
关键词
Microfluidic paper-based analytical device; Nitrite ion; Nitrate ion; On-site analysis; Environmental analysis; SPECTROPHOTOMETRIC METHOD; PLATFORM; SAMPLES; SALIVA; WATER; FOOD;
D O I
10.1016/j.talo.2024.100347
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We used a microfluidic paper-based analytical device (mu PAD) to investigate the influence that zinc reduction exerts on the determination of nitrite and nitrate ions in natural water samples. The mu PAD consists of layered channels for the reduction of nitrate to nitrite with zinc powder and the subsequent detection of nitrite with Griess reagent. The amount of zinc, number of layers, and reaction time for the reduction were optimized to obtain an intense signal for nitrate. Initially, the sensitivity to nitrate corresponded to 55% that of nitrite, which implied an incomplete reduction. We found, however, that zinc decreased the sensitivity to nitrite in both the mu PAD and spectrophotometry. The sensitivity to nitrite was decreased by 48% in spectrophotometry and 68% in the mu PAD following the reaction with zinc. One of the reasons for the decreased sensitivity is attributed to the production of ammonia, as we elucidated that both nitrite and nitrate produced ammonia via the reaction with zinc. The results suggest that the total concentration of nitrite and nitrate must be corrected by constructing a calibration curve for nitrite with zinc, in addition to developing curves for nitrate with zinc and for nitrite without zinc. Using these calibration curves, the absorbance at different concentration ratios of nitrite and nitrate ions could be reproduced via calculation using the calibration curves with zinc for nitrite and nitrate. Eventually, the developed mu PAD was applied to the determination of nitrite and nitrate ions in natural water samples, and the results were compared with those using a conventional spectrophotometric method. The results of the mu PAD are in good agreement with those of conventional spectrophotometry, which suggests that the mu PAD is reliable for the measurement of nitrite and nitrate ions in natural water samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Kazuma Ogawa
    Takashi Kaneta
    Analytical Sciences, 2016, 32 : 31 - 34
  • [22] Microfluidic Paper-Based Analytical Device for Histidine Determination
    Akimitsu Kugimiya
    Akane Fujikawa
    Xiao Jiang
    Z. Hugh Fan
    Toshikazu Nishida
    Jiro Kohda
    Yasuhisa Nakano
    Yu Takano
    Applied Biochemistry and Biotechnology, 2020, 192 : 812 - 821
  • [23] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Ogawa, Kazuma
    Kaneta, Takashi
    ANALYTICAL SCIENCES, 2016, 32 (01) : 31 - 34
  • [24] Microfluidic Paper-Based Analytical Device for Histidine Determination
    Kugimiya, Akimitsu
    Fujikawa, Akane
    Jiang, Xiao
    Fan, Z. Hugh
    Nishida, Toshikazu
    Kohda, Jiro
    Nakano, Yasuhisa
    Takano, Yu
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 192 (03) : 812 - 821
  • [25] Paper-based microfluidic sampling for potentiometric determination of ions
    Lisak, Grzegorz
    Cui, Jingwen
    Bobacka, Johan
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 933 - 939
  • [26] A colorimetric assay system for dopamine using microfluidic paper-based analytical devices
    Liu, Chunye
    Gomez, Frank A.
    Miao, Yanqing
    Cui, Ping
    Lee, Wilson
    TALANTA, 2019, 194 : 171 - 176
  • [27] Strategies for the detection of target analytes using microfluidic paper-based analytical devices
    Wei Zheng
    Kan Wang
    Hao Xu
    Chujun Zheng
    Bo Cao
    Qi Qin
    Qinghui Jin
    Daxiang Cui
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2429 - 2445
  • [28] DEVELOPMENT OF AN ELECTRONIC EXPLOSIVE DETECTOR USING MICROFLUIDIC PAPER-BASED ANALYTICAL DEVICES
    Blanes, Lucas
    Dos Santos, Robson O.
    Diplock, Matthew
    Benson, Natasha
    Doble, Philip
    Roux, Claude
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 199 - 200
  • [29] Acid-Base Titrations Using Microfluidic Paper-Based Analytical Devices
    Karita, Shingo
    Kaneta, Takashi
    ANALYTICAL CHEMISTRY, 2014, 86 (24) : 12108 - 12114
  • [30] Strategies for the detection of target analytes using microfluidic paper-based analytical devices
    Zheng, Wei
    Wang, Kan
    Xu, Hao
    Zheng, Chujun
    Cao, Bo
    Qin, Qi
    Jin, Qinghui
    Cui, Daxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2429 - 2445