Augmented Reality-Guided External Ventricular Drain Placement: A Case Report

被引:0
|
作者
Janssen, Andrew [1 ]
Wang, Arthur [1 ]
Dumont, Aaron S. [2 ]
Delashaw, Johnny [2 ]
机构
[1] Tulane Univ, Sch Med, Dept Neurol Surg, New Orleans, LA 70112 USA
[2] Tulane Univ, Sch Med, Dept Neurosurg, New Orleans, LA USA
关键词
neurotechnology; hydrocephalus; neurosurgery; mixed reality (mr); augmented reality; external ventricular drain (evd); ventriculostomy; neurocritical care unit; ACCURACY;
D O I
10.7759/cureus.64403
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The placement of an external ventricular drain (EVD) is a critical neurosurgical procedure used to relieve intracranial pressure in patients with conditions such as hydrocephalus, traumatic brain injury, and intracranial hemorrhage. Traditional methods rely heavily on anatomical landmarks and the surgeon's experience, which can lead to variability in outcomes and increased risk of complications. Neuronavigation, while available, is infrequently used due to the size, cost, and set-up times associated with these devices. This report explores the use of a headset-based augmented reality (AR) system for guidance during the EVD placement procedure. We describe an AR system that overlays a 3D model of the patient's cranial anatomy, derived from preoperative imaging, onto the patient's head. This system is a head-mounted display and utilizes a rapid fiducial-less registration to provide the surgeon with visualization of 3D anatomy, and targeted trajectories. The system was used with a 32-year-old patient undergoing EVD placement prior to a cranioplasty. Due to the atypical cranial anatomy and due to prior procedures and midline shift, this relatively high-risk catheter placement was an ideal circumstance for the use of AR guidance during the EVD placement. This report described an early use of AR for EVD placement and represents a substantial advancement in neurosurgical practice, offering enhanced precision, efficiency, and safety. Further largescale studies are warranted to validate these findings and explore the broader applicability of AR in other neurosurgical procedures.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] The Enigma of External Ventricular Drain Placement
    Siesjo, Peter
    WORLD NEUROSURGERY, 2014, 82 (05) : 597 - 598
  • [22] Augmented Reality-Guided Artery-First Pancreatico-Duodenectomy
    Ettore Marzano
    Tullio Piardi
    Luc Soler
    Michele Diana
    Didier Mutter
    Jacques Marescaux
    Patrick Pessaux
    Journal of Gastrointestinal Surgery, 2013, 17 : 1980 - 1983
  • [23] Automatic generation of selective disassembly sequences for Augmented Reality-Guided Maintenance
    Zhao, Xin
    Huang, Hao
    Wang, Yue
    Fu, Hongyong
    2024 IEEE 48TH ANNUAL COMPUTERS, SOFTWARE, AND APPLICATIONS CONFERENCE, COMPSAC 2024, 2024, : 719 - 724
  • [24] Automated Procedure Reconfiguration Framework for Augmented Reality-Guided Maintenance Applications
    Young, Crystal
    Rai, Rahul
    JOURNAL OF COMPUTING AND INFORMATION SCIENCE IN ENGINEERING, 2021, 21 (06)
  • [25] Augmented Reality-Guided Artery-First Pancreatico-Duodenectomy
    Marzano, Ettore
    Piardi, Tullio
    Soler, Luc
    Diana, Michele
    Mutter, Didier
    Marescaux, Jacques
    Pessaux, Patrick
    JOURNAL OF GASTROINTESTINAL SURGERY, 2013, 17 (11) : 1980 - 1983
  • [26] Augmented reality-guided localization of a chest wall tumor in a pediatric patient
    Spijkerboer, Koen G. P.
    Fitski, Matthijs
    Siepel, Francoise J.
    Ven, Cornelis P. van de
    Steeg, Alida F. W. van der
    EUROPEAN JOURNAL OF CANCER, 2022, 170 : 103 - 105
  • [27] Device for Catheter Placement of External Ventricular Drain
    Ann, Jae-Min
    Bae, Hack-Gun
    Oh, Jae-Sang
    Yoon, Seok-Mann
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2016, 59 (03) : 322 - 324
  • [28] Percutaneous placement of lumbar pedicle screws via intraoperative CT image-based augmented reality-guided technology
    Liu, Huan
    Wu, Junlong
    Tang, Yu
    Li, Haiyin
    Wang, Wenkai
    Li, Changqing
    Zhou, Yue
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (04) : 542 - 547
  • [29] Accuracy of augmented reality-guided needle placement for pulsed radiofrequency treatment of pudendal neuralgia: a pilot study on a phantom model
    Boogaard, Lars L.
    Notten, Kim
    Kluivers, Kirsten
    Van der Wal, Selina
    Maal, Thomas J. J.
    Verhamme, Luc
    PEERJ, 2024, 12
  • [30] Targeted augmented reality-guided transperineal prostate biopsies study: initial experience
    Theivendrampillai, Shenthiuiyan
    Yang, Bob
    Little, Mark
    Blick, Christopher
    THERAPEUTIC ADVANCES IN UROLOGY, 2024, 16