Promoted Non-enzymatic Glucose Sensor Based on Synergistic Effect of Hydrothermal Synthesized Ni(OH)2-Graphene Nanocomposite

被引:0
|
作者
Cai, Yuqing [1 ]
Cui, Qingyan [2 ]
Zhang, Huanrong [2 ]
Ma, Xinlei [1 ]
Xue, Mianqi [2 ]
机构
[1] Renmin Univ China, Sch Chem & Life Resources, Beijing 100872, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Glucose sensing; Non-enzyme sensor; Graphene; 2D material; Ni(OH)(2) nanosheet; GRAPHENE OXIDE; DIABETES MANAGEMENT; ARCHITECTURE;
D O I
10.1007/s40242-024-4170-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Although glucose electrochemical sensors based on enzymes play a dominant role in market, their stability remains a problem due to the inherent nature of enzymes. Therefore, glucose sensors that are independent on enzymes have attracted more attention for the development of stable detection devices. Here we present an enzyme-free glucose sensor based on Ni(OH)(2) and reduced graphene oxide (rGO). The as-fabricated sensor still exhibits excellent electrocatalytic activity for detecting glucose under enzyme independent conditions. The enhanced catalytic performance may due to synergistic effect as follows: (i) the interaction between the Ni2+ and pi electron of graphene induces the formation of the beta-phase Ni(OH)(2) with higher catalytic activity; (ii) the frozen dry process works as a secondary filtration, getting rid of poorly formed Ni(OH)(2) particles with low catalytic activity; (iii) the rGO network with good conductivity provides a good electronic pathway for promoting electron transfer to reduce the response time. Based on the synergistic effect, the sensor exhibits a wide linear detection range from 0.2 mu mol/L to 1.0 mu mol/L and a low detection limit (0.1 mu mol/L, S/N=3). The excellent detection performance, as well as the easy and low-cost preparation method, suggests the promising applicability of the sensor in the glucose detection market.
引用
收藏
页码:914 / 921
页数:8
相关论文
共 50 条
  • [21] A non-enzymatic glucose sensor based on Ni/PANI coaxial nanowire arrays
    Wang, Hongzhi
    Qiu, Jianrui
    Sun, Shaofeng
    Zhang, Weiguo
    Yao, Suwei
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (06) : 7751 - 7764
  • [22] A Review on the Development of Non-Enzymatic Glucose Sensor Based on Graphene-Based Nanocomposites
    Leong, Khok Lun
    Ho, Mui Yen
    Lee, Xiau Yeen
    Yee, Maxine Swee-Li
    NANO, 2020, 15 (11)
  • [23] An integrated anode based on porous Ni/Cu(OH)2 nanospheres for non-enzymatic glucose sensing
    Zhe, Taotao
    Sun, Xinyu
    Liu, Yingnan
    Wang, Qinzhi
    Li, Fan
    Bu, Tong
    Jia, Pei
    Lu, Qingyou
    Wang, Jihao
    Wang, Li
    MICROCHEMICAL JOURNAL, 2019, 151
  • [24] A Nafion-free non-enzymatic amperometric glucose sensor based on copper oxide nanoparticles-graphene nanocomposite
    Alizadeh, Taher
    Mirzagholipur, Shabnam
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 438 - 447
  • [25] Highly sensitive non-enzymatic glucose sensor based on over-oxidized polypyrrole nanowires modified with Ni(OH)2 nanoflakes
    Yang, Jiao
    Cho, Misuk
    Pang, Changhyun
    Lee, Youngkwan
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 93 - 101
  • [26] CuO/reduced graphene oxide nanocomposite for high performance non-enzymatic, cost effective glucose sensor
    Sahu V.
    Grover S.
    Sharma M.
    Pandey A.
    Singh G.
    Sharma R.K.
    Sensor Letters, 2016, 14 (11) : 1117 - 1122
  • [27] Ni(OH)2/MoSx nanocomposite electrodeposited on a flexible CNT/PI membrane as an electrochemical glucose sensor: the synergistic effect of Ni(OH)2 and MoSx
    Qin Wang
    Yan Zhang
    Weichun Ye
    Chunming Wang
    Journal of Solid State Electrochemistry, 2016, 20 : 133 - 142
  • [28] Preparation of Ni(OH)2 nanosheets on Ni foam via a direct precipitation method for a highly sensitive non-enzymatic glucose sensor
    Zhao, Yudong
    Gu, Gaochen
    You, Shengquan
    Ji, Renhua
    Suo, Hui
    Zhao, Chun
    Liu, Fengmin
    RSC ADVANCES, 2015, 5 (66) : 53665 - 53670
  • [29] Facile synthesis of Ni(OH)2 nanowires on nickel foam via one step low-temperature hydrothermal route for non-enzymatic glucose sensor
    Xiao, Qi
    Wang, Xinxin
    Huang, Suping
    MATERIALS LETTERS, 2017, 198 : 19 - 22
  • [30] Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
    Sakr, Mahmoud A.
    Elgammal, Karim
    Delin, Anna
    Serry, Mohamed
    SENSORS, 2020, 20 (01)