Solar PV system with maximum power tracking

被引:0
|
作者
Gusev, G. N. [1 ,2 ]
Zhdaneev, O. V. [3 ,4 ]
Gainullin, M. E. [2 ]
Argastsev, A. Yu [5 ]
Lapkin, D. N. [2 ]
机构
[1] NRTU HE Nat Res Technol Univ MISIS, Dept Energy & Energy Efficiency Min Industry, 4 Leninsky Prospekt,Bldg 1, Moscow 119049, Russia
[2] Parus Electro LLC, St 6th Radialnaya 9, Moscow 115404, Russia
[3] Yugra State Univ, Fed State Budgetary Inst Educ Inst Higher Educ, Chekhova Str,Khanty Mansi Autonomous Okrug Yugra, Khanty Mansiysk 628012, Tyumen, Russia
[4] Inst Petrochem Synth AV Topchiev Russian Acad Sci, Fed State Budgetary Inst Sci Order Red Banner Labo, GSP-1,Leninsky Prospekt 29, Moscow 119991, Russia
[5] JSC Rusatom Automated Control Syst, Sh Kashirskoye 3 Bldg 2,Bldg 16, Moscow 115230, Russia
关键词
Hydrogen; Hydrogen energy; Hydrogen storage; Solar inverter; Maximum power point photovoltaic system; MPPT; Insolation; Nickel-hydrogen battery; Fuzzy particle swarm optimization; Watt-volt characteristic of solar panel;
D O I
10.1016/j.ijhydene.2024.08.441
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The paper investigates the state-of-the-art architecture of photovoltaic systems (PVS) by evaluating the performance of the developed maximum power point tracking (MPPT) algorithm of fuzzy particle swarm optimization (FPSO) for temperate continental latitudes. The material of the paper gives an evaluation of traditional MPPT algorithms in relation to the state-of-the-art FPSO algorithm. The study summarizes the problems of On-Grid PV systems and analyzes methods of solving them by combining them with hydrogen technologies. The paper summaries the experience of observations of climatic factors and solar resources on the example of the Russian Federation. Thus, in 2023, the average winter temperature exceeded the norm by 4.7 degrees C, and the average summer temperature exceeded the norm by 4.9 degrees C compared to 2022. The paper analyses the level of insolation, which increased by 0.03 kWh/m(2) by regions of Russia for the period 2022-2023. The experimental part of the work was carried out at the solar power plant (SPP) << Kalmykskaya >> with coordinates 53.422832 north latitude and 55.266895 east longitude. The watt-volt field characteristic of photovoltaic modules (PVM) connected to the inverter was obtained experimentally. When compared, the correlation coefficient between the experimental power (P) and voltage (U) of the panels was found to be higher than that of the ideal panels, 0.933 versus 0.914. The correlation coefficient between the ideal P(U) function and the experimental one is (-0.475). The data for calculating the coefficient of performance (COP) of the implemented MPPT algorithm was also obtained experimentally, which was about 98.7%. The reliability of the data used in the calculations was confirmed by two independent means of measurement, the difference of the obtained results was less than 1%. In the last part of the experiment of this study, the dependence of insolation in a given geographical point on the generated PV field power was evaluated. The correlation coefficient was 0.47, while the inverter output voltage was maintained in the nominal range of (600 +/- 20%)V. Thus, the authors of the study experimentally proved the efficiency of using MPPT on FPSO in temperate continental climate with duration of sunshine T = 1850 h per year. The effectiveness of the FPSO algorithm under the conditions of inverter distance from the common point of the DC switching cabinet (D & Scy;CC) has been confirmed. The effectiveness of the MPPT algorithm based on FPSO under conditions of partial shading, increased cloud cover and increased air temperature is concluded. Using the description of the current architecture of On-Grid SPP, the authors draw attention to the impossibility of operation of such systems without the presence of voltage in the reference network. In addition, the impossibility of the system operation at the value of PVM power over 1500 kW and at the voltage of panels less than 900 V is noted. To modernize the existing PVS architecture, for the first time, the use of a DCCC and an inverter with implemented MPPT on the FPSO in combination with a hydrogen (H-2) production unit and nickel-hydrogen (Ni-H-2) batteries is proposed. The researchers propose that when the PVM field voltage is below 900 V and when the PVM field power exceeds 1500 kW, energy can be diverted to H2 generation or to charge Ni-H2 batteries via a DCCC controller. Such an architecture will improve the continuity and efficiency of the PVS, reduce the carbon footprint, and allow the PVS to be used as an industrial uninterruptible power supply (UPS). The authors see the lack of standardization of implemented projects based on the ESG principle as the main problem of alternative energy development.
引用
收藏
页码:258 / 267
页数:10
相关论文
共 50 条
  • [21] Modulated Perturb and Observe Maximum Power Point Tracking Algorithm for Solar PV Energy Conversion System
    Satapathy, Susree Sukanya
    Kumar, Nishant
    2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 345 - 350
  • [22] Neural network maximum power point tracking for performance improvement of solar PV water pumping system
    Harrag, Abdelghani
    JOURNAL OF PHOTONICS FOR ENERGY, 2019, 9 (04)
  • [23] Improved solar system with maximum power point tracking
    Hua, Chih-Chiang
    Fang, Yi-Hsiung
    Wong, Cyuan-Jyun
    IET RENEWABLE POWER GENERATION, 2018, 12 (07) : 806 - 814
  • [24] Modeling of solar PV module and maximum power point tracking using ANFIS
    Kharb, Ravinder Kumar
    Shimi, S. L.
    Chatterji, S.
    Ansari, Md Fahim
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 : 602 - 612
  • [25] An Internet of Things to Maximum Power Point Tracking Approach of Solar PV Array
    Manghani, Himanshu
    Ram, J. Prasanth
    Rajasekar, N.
    ADVANCES IN SMART GRID AND RENEWABLE ENERGY, 2018, 435 : 401 - 409
  • [26] A comprehensive review on solar PV maximum power point tracking czossMark techniques
    Ram, J. Prasanth
    Babu, T. Sudhakar
    Rajasekar, N.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 826 - 847
  • [27] Maximum Power Point Tracking System for Stand Alone Solar PV Power System Using Adaptive Neuro-Fuzzy Inference System
    Mohammed, S. Sheik
    Devaraj, D.
    Ahamed, T. P. Imthias
    2016 BIENNIAL INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY (PESTSE), 2016,
  • [28] Dynamic Neural Control for Maximum Power Point Tracking of PV System
    Dounis, Anastasios I.
    Kofinas, P.
    Alafodimos, C.
    Tseles, D.
    ELEVENTH SYMPOSIUM ON NEURAL NETWORK APPLICATIONS IN ELECTRICAL ENGINEERING (NEUREL 2012), 2012,
  • [29] A Maximum Power Point Tracking of PV System by Scaling Fuzzy Control
    Chang, Yuen-Haw
    Chang, Chia-Yu
    INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS (IMECS 2010), VOLS I-III, 2010, : 1212 - 1216
  • [30] Development of an Autonomous Distributed Maximum Power Point Tracking PV System
    Chen, Yaow-Ming
    Chen, Cheng-Wei
    Chen, Yang-Lin
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 3614 - 3619