Solar PV system with maximum power tracking

被引:0
|
作者
Gusev, G. N. [1 ,2 ]
Zhdaneev, O. V. [3 ,4 ]
Gainullin, M. E. [2 ]
Argastsev, A. Yu [5 ]
Lapkin, D. N. [2 ]
机构
[1] NRTU HE Nat Res Technol Univ MISIS, Dept Energy & Energy Efficiency Min Industry, 4 Leninsky Prospekt,Bldg 1, Moscow 119049, Russia
[2] Parus Electro LLC, St 6th Radialnaya 9, Moscow 115404, Russia
[3] Yugra State Univ, Fed State Budgetary Inst Educ Inst Higher Educ, Chekhova Str,Khanty Mansi Autonomous Okrug Yugra, Khanty Mansiysk 628012, Tyumen, Russia
[4] Inst Petrochem Synth AV Topchiev Russian Acad Sci, Fed State Budgetary Inst Sci Order Red Banner Labo, GSP-1,Leninsky Prospekt 29, Moscow 119991, Russia
[5] JSC Rusatom Automated Control Syst, Sh Kashirskoye 3 Bldg 2,Bldg 16, Moscow 115230, Russia
关键词
Hydrogen; Hydrogen energy; Hydrogen storage; Solar inverter; Maximum power point photovoltaic system; MPPT; Insolation; Nickel-hydrogen battery; Fuzzy particle swarm optimization; Watt-volt characteristic of solar panel;
D O I
10.1016/j.ijhydene.2024.08.441
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The paper investigates the state-of-the-art architecture of photovoltaic systems (PVS) by evaluating the performance of the developed maximum power point tracking (MPPT) algorithm of fuzzy particle swarm optimization (FPSO) for temperate continental latitudes. The material of the paper gives an evaluation of traditional MPPT algorithms in relation to the state-of-the-art FPSO algorithm. The study summarizes the problems of On-Grid PV systems and analyzes methods of solving them by combining them with hydrogen technologies. The paper summaries the experience of observations of climatic factors and solar resources on the example of the Russian Federation. Thus, in 2023, the average winter temperature exceeded the norm by 4.7 degrees C, and the average summer temperature exceeded the norm by 4.9 degrees C compared to 2022. The paper analyses the level of insolation, which increased by 0.03 kWh/m(2) by regions of Russia for the period 2022-2023. The experimental part of the work was carried out at the solar power plant (SPP) << Kalmykskaya >> with coordinates 53.422832 north latitude and 55.266895 east longitude. The watt-volt field characteristic of photovoltaic modules (PVM) connected to the inverter was obtained experimentally. When compared, the correlation coefficient between the experimental power (P) and voltage (U) of the panels was found to be higher than that of the ideal panels, 0.933 versus 0.914. The correlation coefficient between the ideal P(U) function and the experimental one is (-0.475). The data for calculating the coefficient of performance (COP) of the implemented MPPT algorithm was also obtained experimentally, which was about 98.7%. The reliability of the data used in the calculations was confirmed by two independent means of measurement, the difference of the obtained results was less than 1%. In the last part of the experiment of this study, the dependence of insolation in a given geographical point on the generated PV field power was evaluated. The correlation coefficient was 0.47, while the inverter output voltage was maintained in the nominal range of (600 +/- 20%)V. Thus, the authors of the study experimentally proved the efficiency of using MPPT on FPSO in temperate continental climate with duration of sunshine T = 1850 h per year. The effectiveness of the FPSO algorithm under the conditions of inverter distance from the common point of the DC switching cabinet (D & Scy;CC) has been confirmed. The effectiveness of the MPPT algorithm based on FPSO under conditions of partial shading, increased cloud cover and increased air temperature is concluded. Using the description of the current architecture of On-Grid SPP, the authors draw attention to the impossibility of operation of such systems without the presence of voltage in the reference network. In addition, the impossibility of the system operation at the value of PVM power over 1500 kW and at the voltage of panels less than 900 V is noted. To modernize the existing PVS architecture, for the first time, the use of a DCCC and an inverter with implemented MPPT on the FPSO in combination with a hydrogen (H-2) production unit and nickel-hydrogen (Ni-H-2) batteries is proposed. The researchers propose that when the PVM field voltage is below 900 V and when the PVM field power exceeds 1500 kW, energy can be diverted to H2 generation or to charge Ni-H2 batteries via a DCCC controller. Such an architecture will improve the continuity and efficiency of the PVS, reduce the carbon footprint, and allow the PVS to be used as an industrial uninterruptible power supply (UPS). The authors see the lack of standardization of implemented projects based on the ESG principle as the main problem of alternative energy development.
引用
收藏
页码:258 / 267
页数:10
相关论文
共 50 条
  • [1] Maximum Power Point Tracking for Solar PV System
    Gupta, Subhash
    Kalika, S.
    Cabigting, Luisito R.
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 2034 - 2037
  • [2] An Improved Maximum Power Point Tracking Method for Solar PV System
    Liu, Yali
    Li, Ming
    Ji, Xu
    Luo, Xi
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING III, PTS 1-3, 2013, 368-370 : 1327 - +
  • [3] AC PV Solar System Distributed Architecture with Maximum Power Point Tracking
    Jiang, Yuncong
    Abu Qahouq, Jaber A.
    Orabi, Mohamed
    2012 IEEE 34TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2012,
  • [4] A comparative investigation of maximum power point tracking methods for solar PV system
    Gupta, Ankit
    Chauhan, Yogesh K.
    Pachauri, Rupendra Kumar
    SOLAR ENERGY, 2016, 136 : 236 - 253
  • [5] Differential power algorithm based maximum power point tracking for a standalone solar PV system
    Sharma, Dinesh K.
    Purohit, Ghanshyam
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2015, 26 (02) : 103 - 109
  • [6] Algorithm for Tracking the Maximum Power from PV System
    Bharati, Kamlesh K.
    Singh, Vijay P.
    Patel, R. K.
    Singh, S. P.
    2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 693 - 697
  • [7] Maximum Power Angle (MPA) Based Maximum Power Point Tracking (MPPT) Technique for Efficiency Optimization of Solar PV System
    Sharma, D. K.
    Purohit, G.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2014, 4 (03): : 810 - 815
  • [8] A New Dual Inverter Based Solar PV System with Maximum Power Point Tracking Capability
    Basu, Tuhin S.
    Maiti, Suman
    Chakraborty, Chandan
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 172 - 177
  • [9] INTEGRATION OF SOLAR TRACKER AND MAXIMUM POWER POINT TRACKING FOR IMPROVING PHOTOVOLTAIC (PV) SYSTEM EFFICIENCY
    Soetedjo, Aryuanto
    Sulistiawati, Irrine Budi
    Nakhoda, Yusuf Ismail
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2020, 16 (02): : 429 - 443
  • [10] Simulation model of ANN based maximum power point tracking controller for solar PV system
    Rai, Anil K.
    Kaushika, N. D.
    Singh, Bhupal
    Agarwal, Niti
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2011, 95 (02) : 773 - 778