A non-invasive pipeline heat flux measurement method and application based on CFBG

被引:0
|
作者
Cai, Qihui [1 ,2 ]
Liu, Mingyao [1 ,2 ]
Song, Han [1 ,2 ]
Li, Cong [1 ,2 ]
Ren, Yunhao [1 ,2 ]
机构
[1] Wuhan Univ Technol, Sch Mech & Elect Engn, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Hubei Key Lab Digital Mfg, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Chirped fiber Bragg grating; Heat flux sensor; High spatial resolution; Single measuring point; Pipeline heat flux monitoring; CONVECTION;
D O I
10.1016/j.ijheatmasstransfer.2024.126124
中图分类号
O414.1 [热力学];
学科分类号
摘要
A non-invasive, real-time monitoring, spectral analysis heat flux sensor with single measuring point based on chirp fiber Bragg grating (CFBG) has been proposed in this paper. When CFBG senses heat flux, the linear increase of axial thermal expansion leads to spectral broadening. The measurement of heat flux can be realized by the measurement of the full width at half maximum (FWHM). The theoretical model and working principle of CFBG heat flux sensor are established to determine the heat flux sensing characteristics of CFBG. The numerical analysis and theoretical calculation show that CFBG heat flux sensor can realize stable transformation of heat flux and FWHM. A heat flux calibration platform was built and its feasibility was verified by simulation. The sensitivity of CFBG sensor to monitor heat flux in a wide temperature range is 1.078 pm/(W/m(2)). The heat flux of the pipe wall at the outlet of the axial variable piston pump in the hydraulic system was quantitatively measured by the CFBG heat flux sensor. The sensor has a spatial resolution of 1 cm, a length of 10 mm, a diameter of 0.125 mm, and a sensitivity of 1.078 pm/(W/m(2)). It has the advantages of high spatial resolution, single measurement point, real-time measurement, small installation space, and non-invasiveness. The theoretical model can provide theoretical guidance for the design of fiber grating heat flux sensor, and it is convenient to design a series of sensors for specific measurement requirements.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    Brajkovic, D
    Ducharme, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 94 (04) : 386 - 391
  • [42] A non-invasive form finding method with application to metal forming
    Landkammer P.
    Schneider T.
    Schulte R.
    Steinmann P.
    Merklein M.
    Production Engineering, 2016, 10 (1) : 93 - 102
  • [43] The heat flux measurement method based on isotherm registration
    Alekseev, AK
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (07) : 1643 - 1646
  • [44] Non-Invasive Measurement of Intracranial Pressure Through Application of Venous Ophthalmodynamometry
    Lo, Lachlan
    Zhao, Da
    Ayton, Lauren
    Grayden, David
    Bui, Bang
    Morokoff, Andrew
    John, Sam
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6771 - 6774
  • [45] Review of Stratum Corneum Impedance Measurement in Non-Invasive Penetration Application
    Lu, Fei
    Wang, Chenshuo
    Zhao, Rongjian
    Du, Lidong
    Fang, Zhen
    Guo, Xiuhua
    Zhao, Zhan
    BIOSENSORS-BASEL, 2018, 8 (02):
  • [46] Application of EMD algorithm to the dynamic spectrum non-invasive measurement of hemoglobin
    Lin, Ling
    Li, Wei
    Zhou, Mei
    Zeng, Rui-Li
    Li, Gang
    Zhang, Bao-Ju
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2014, 34 (08): : 2106 - 2111
  • [47] Application of EMD Algorithm to the Dynamic Spectrum Non-Invasive Measurement of Hemoglobin
    Lin Ling
    Li Wei
    Zhou Mei
    Zeng Rui-li
    Li Gang
    Zhang Bao-ju
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (08) : 2106 - 2111
  • [48] A pilot study demonstrating a non-invasive method for the measurement of protein turnover in skin disorders: application to psoriasis
    Emson, Claire L.
    Fitzmaurice, Sarah
    Lindwall, Glen
    Li, Kelvin W.
    Hellerstein, Marc K.
    Maibach, Howard I.
    Liao, Wilson
    Turner, Scott M.
    CLINICAL AND TRANSLATIONAL MEDICINE, 2013, 2
  • [49] NON-INVASIVE MEASUREMENT OF PULMONARY TRANS-VASCULAR PROTEIN FLUX IN NORMAL MAN
    GORIN, AB
    KOHLER, J
    DENARDO, G
    JOURNAL OF CLINICAL INVESTIGATION, 1980, 66 (05): : 869 - 877
  • [50] The calibration model in potassium ion flux non-invasive measurement of plants in vivo in situ
    Xue L.
    Zhao D.-J.
    Wang Z.-Y.
    Wang X.-D.
    Wang C.
    Huang L.
    Wang Z.-Y.
    Information Processing in Agriculture, 2016, 3 (02): : 76 - 82